14. Remove front panel frame and filter. Remove 2
screws securing front panel frame in place. Press
down on top edge of front panel frame, tilt forward,
and lift up off the bottom spring clips. Remove filter.
NOTE: DO NOT push or pull the air direction louvers.
15. Place unit into the window opening on platform
assembly. Place window panel frame, and cabinet
side channels against the top and side window
jambs.
Slide inner
window sash
frimly against
cabinet
16. Slide inner window sash firmly against side of
cabinet. Make sure not to peel seal strips from
window track and cabinet side channels. If panel
frame does not fit snugly to inner window sash,
secure panel frame to the sash with #8x3/4-inch
screws, or #8-32x3/4-inch self-threading screws. Use
partially plugged holes in panel frame to drill 1/8-inch
pilot holes for screws.
17. Hook safety bracket over base of the unit and fasten
to the front of platform assembly. Use a #8-32x3/4
inch self-threading screw.
Safety bracket
NOTE: Bracket prevents movement of air conditioner
(either in or out) after completing installation.
18. Stuff foam seal strip/sash seal between vertical sash
and window glass.
19. Use window locking bracket to lock inner window
sash to base of outer window sash. Use a
#8x3/4-inch screw, or #8-32x3/4-inch self-threading
screw. (Drill 1/8-inch pilot hole.)
20. Replace air conditioner filter and front panel frame.
Make sure to replace screws that secure front panel
frame in place.