SERVICING
61
A
DVANCED
U
SER
M
ENUS
SUBMENU ITEM
USER MODIFIABLE OPTIONS
COMMENTS
PUMP DOWN
ON or OFF
Enter PUMP DOWN Mode. This procedure runs the equipment
for approximately 15 minutes and allows accumulation of
refrigerant at the outdoor unit for purposes of removing &
replacing the indoor unit or outdoor unit.
CHARGE MODE
ON or OFF
Enter Charging Mode. This allows for a steady system
operation for a duration of approximately 1 hour to allow for
refrigerant charging of the system via the suction charge port.
The system will stop after completion.
SUBMENU ITEM
USER MODIFIABLE OPTIONS
COMMENTS
CL Reset
YES or NO
Selecting to default factory setting.
Cool Airflow Trim Hi (C TR H)
15% to +15% in 3% increments
Selects the cooling airflow trim amount.
Cool Airflow Trim Int (C TR
I
)
15% to +15% in 3% increments
Selects the cooling airflow trim amount.
Cool Airflow Trim Low (C TR L)
15% to +15% in 3% increments
Selects the cooling airflow trim amount.
Cool Airflow Profile
A, B, C, or D
Selects the cooling airflow profile.
Cool ON Delay
5, 10, 20, 30 seconds
Selects the indoor blower ON delay.
Cool OFF Delay
30, 60, 90, 120 seconds
Selects the indoor blower OFF delay.
Dehumidification Select
ON or OFF
Selecting OFF disables dehumidification; selecting ON enables
dehumidification.
SUBMENU ITEM
USER MODIFIABLE OPTIONS
COMMENTS
Maximum Compressor RPS Range for
Cooling (COOL RPS RANGE)
Five different compressor RPS
ranges will be provided.
Select the appropriate range for the installed system
configuration.
Maximum Compressor RPS Selection for
Cooling (COOL RPS SELECT)
10 compressor RPS values will be
provided within the range selected
in the COOL RPS RANGE menu
Select the appropriate compressor RPS for the installed system
configuration.
COOL SETUP
SET COOLING RUN VALUES (CL RUN VALUES)
SYSTEM MAINTENANCE