NOTE:
The Temperature Rise Tables can also be used to estimate the air handler airflow delivery. When using these
tables for this purpose set the room thermostat to maximum heat and allow the system to reach steady state conditions.
Insert two thermometers, one in the return air and one in the supply air. The temperature rise is the supply air temperature
minus the room air temperature. Using the temperature rise calculated, CFM can be estimated from the TR formula
above. See Technical Manual and/or Service Manual for more information.
230/1/60 SUPPLY VOLTAGE - TEMP. RISE °F
Table 2
3
5
6
8
10
15 19/20 25
800
12
19
23
31
37
1000
9
15
19
25
30
44
1200
8
12
15
21
25
37
49
62
1400
7
11
13
18
21
32
42
53
1600
6
9
12
15
19
28
37
46
1800
5
8
10
14
16
25
33
41
2000
5
7
9
12
15
22
30
37
CFM
HEAT KIT NOMINAL kW
220/1/60 SUPPLY VOLTAGE - TEMP. RISE °F
Table 3
3
5
6
8
10
15 19/20 25
800
11
18
22
30
35
1000
9
14
18
24
28
42
1200
7
12
15
20
24
35
47
59
1400
6
10
13
17
20
30
40
51
1600
6
9
11
15
18
27
35
44
1800
5
8
10
13
16
24
31
39
2000
4
7
9
12
14
21
28
35
CFM
HEAT KIT NOMINAL kW
208/1/60 SUPPLY VOLTAGE - TEMP. RISE °F
Table 4
3
5
6
8
10
15 19/20 25
800
10
17
21
28
33
1000
8
13
17
22
27
40
1200
7
11
14
19
22
33
45
56
1400
6
10
12
16
19
29
38
48
1600
5
8
10
14
17
25
33
42
1800
5
7
9
12
15
22
30
37
2000
4
7
8
11
13
20
27
33
CFM
HEAT KIT NOMINAL kW
3
5
6
8
10
15
19
20
25
ARUF25B14
715
715
715
715
950
ARUF29B14
715
715
715
715
950
ARUF31B14
715
715
715
715
875
875
ARUF37C14
1170
1170
1170
1170
1345
1345
ARUF43C14
1170
1170
1170
1170
1345
1345
ARUF49C14
1170
1170
1170
1170
1340
1430
ARUF37D14
1170
1170
1170
1170
1345
1345
ARUF43D14
1170
1170
1170
1170
1345
1345
ARUF47D14
1170
1170
1170
1170
1345
1345
ARUF49D14
1240
1240
1240
1240
1520
1520
ARUF61D14
1590
1590
1590
1590
1715
1715
1715
ASPT61D14
1590
1590
1590
1590
1715
1715
1715
MODEL
HEATER KIT (KW)
MINIMUM CFM REQUIRED FOR HEATER KITS
Table 5