REPLACEMENT PARTS

Ordering Parts

When reporting shortages or damages, or ordering repair 

parts, give the complete unit model and serial numbers as 

stamped on the unit’s nameplate. 

Replacement parts for this appliance are available through 

your contractor or local distributor. Your nearest distributor 

can be located online at 

https://partner.goodmanmfg.com/ 

or by contacting:

HOMEOWNER’S SUPPORT

GOODMAN COMPANY, L.P.

19001 KERMIER ROAD

WALLER, TX 77484

855-770-5678

SAFETY INSTRUCTIONS

To The Installer

Before installing this unit, please read this manual to famil-

iarize  yourself on the specific items which must be adhered 

to, including maximum external static pressure to unit, air 

temperature rise, minimum or maximum CFM and motor 

speed connections.

To The Owner

A warranty certificate is provided with the unit. Read the war

-

ranty carefully and note what is covered. Keep the warranty 

certificate in a safe place so you can find it when necessary.

Keep this literature in a safe place for future reference.

WARNING

If the information in these instructions is not followed 

exactly, a fire or explosion may result causing property 

damage, personal injury or loss of life. 

- do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance. 

- WHAT TO DO IF YOU SMELL GAS: 

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone 

in your building. 

• Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions. If 

you cannot reach your gas supplier, call the fire 

department. 

- Installation and service must be performed by a qualified 

installer, service agency or the gas supplier. 

WARNING

Should overheating occur or the gas supply fail to shut 

off, turn off the manual gas shutoff valve external to the 

furnace before turning off the electrical supply.

WARNING

Do not connect to or use any device that is not design 

certified by the manufacturer for use with this unit. Serious 

property damage, personal injury, reduced unit performance 

and/or hazardous conditions may result from the use of such 

non-approved devices.

WARNING

Heating unit should not be utilized without reasonable, 

routine, inspection, maintenance and supervision. If the 

building in which any such device is located will be vacant, 

care should be taken that such device is routinely inspected, 

maintained and monitored. In the event that the building 

maybe exposed to freezing temperatures and will be vacant, 

all water-bearing pipes should be drained, the building 

should be properly winterized, and the water source closed. 

In the event that the building may be exposed to freezing 

temperatures and will be vacant, any hydronic coil units 

should be drained as well and, in such case, alternative heat 

sources should be utilized. 

WARNING

To avoid property damage, personal injury or death, do not 

use this unit if any part has been under water. Immediately 

call a qualified service technician to inspect the uni y and to 

replace any part of the control system and any gas control 

having been under water.

WARNING

This unit must not be used as a “construction heater” during 

the finishing phases of construction on a new structure. This 

type of use may result in premature failure of the unit due 

to extremely low return air temperatures and exposure to 

corrosive or very dirty atmosphere.

WARNING

High Voltage!

Disconnect ALL power before servicing or 

installing thus unit. Multiple power sources may 

be present. Failure to do so may cause property 

damage, personal injury, or death.

WARNING

To prevent the risk of property damage, personal injury, or 

death, do not store combustible materials or use gasoline 

or other flammable liquids or vapors in the vicinity of this 

appliance.

WARNING

FIRE HAZARD

Failure to follow the safety warnings exactly could result 

in serious injury, death or property damage. Never test for 

gas leaks with an open flame. Use commercially available 

soap solution made specifically for the detection of leaks 

to check all connections. A fire or explosion may result 

causing property damage, persona l injury, or loss of life.

Содержание APG 16 M Series

Страница 1: ...anada shown below ANSI Z21 47 CSA 2 3 Gas Fired Central Furnaces IMPORTANT This product has been designed and manufactured to meet ENERGY STAR criteria for energy efficiency when matched with appropri...

Страница 2: ...bcooling 18 TROUBLESHOOTING 18 Ignition Control Error Codes 18 Fault Recall 18 Abnormal Operation Heating 18 Internal Control Failure 18 External Lockout 18 Pressure Switch Stuck Open 19 Pressure Swit...

Страница 3: ...for use with this unit Serious property damage personal injury reduced unit performance and or hazardous conditions may result from the use of such non approved devices WARNING Heating unit should not...

Страница 4: ...hen Tested As Outlined Above Return Doors Windows Exhaust Fans Fireplace Dampers And Any Other Gas fired Burning Appliance To Their Previous Conditions Of Use RISQUE D INTOXICATION AU MONOXYDE DE CARB...

Страница 5: ...0259 216 El mon xido de carbono puede causar enfermedades severas como da o cerebral permanente muerte Las emisiones de mon xido de carbono pueden circular a trav s del aparato cuando se opera en cual...

Страница 6: ...maintained The combustion air inlet and flue outlet hoods on the unit must never be obstructed If used do not allow the economizer manual fresh air damper motorized fresh air damper to become blocked...

Страница 7: ...the Installation Manual provided with the LP kit for conversion from natural gas to propane gas Natural Min 5 0 W C Max 10 0 W C Propane Min 11 0 W C Max 13 0 W C INLET GAS PRESSURE Inlet Gas Pressure...

Страница 8: ...metallic fittings Aluminum alloy tubing must not be used in exterior locations Listedgasapplianceconnectorsusedinaccordance with the terms of their listing that are completely in the same room as the...

Страница 9: ...0 161 365 679 1 149 1 769 961 2 009 150 130 293 546 923 1 421 772 1 613 200 111 251 467 790 1 216 660 1 381 250 90 222 414 700 1 078 585 1 224 300 89 201 378 634 976 530 1 109 350 82 185 345 584 898 4...

Страница 10: ...Two FAN ONLY speeds are possible with these mo tors To utilize the LOW HEAT blower speed for FAN ONLY operation connect the wire from the thermostat s G terminal to the ignition control board s G term...

Страница 11: ...r HACR circuit breaker that is in excess of the circuit ampacity but less than or equal to the maximum overcurrent protection device DO NOT EXCEED THE MAXIMUM OVERCURRENT DEVICE SIZE SHOWN ON UNIT DAT...

Страница 12: ...aintained The supply duct should be provided with an access panel large enough to inspect the air chamber downstream of the heat exchanger A cover should be tightly attached to prevent air leaks For d...

Страница 13: ...indoor blower is de energized NOTE A 180 second anti short cycle is integral to the con trol and prevents recycling of the compressor Fan Only 1 Thermostat calls for FAN ONLY by energizing G 2 The ind...

Страница 14: ...t 3 Set the room thermostat to its lowest possible setting 4 Remove the heat exchanger door on the side of the unit by removing screws 5 This unit is equipped with an ignition device which automatical...

Страница 15: ...3 w c 2 0 w c High Stage 3 2 3 8 w c 3 5 w c Low Stage 5 7 6 3 w c 6 0 w c High Stage 9 7 10 3 w c 10 0 w c Gas Manifold Gas Pressure Natural Propane Manifold Gas Pressure 8 Remove regulator cover sc...

Страница 16: ...uct at the inlet of the unit Negative Pressure Total External Static 2 Measure the Static pressure of the supply duct Positive Pressure 3 Add the two readings together NOTE Both readings may be taken...

Страница 17: ...n the unit 7 If cooling and or air circulation will be desired turn ON the electrical power Cooling Startup NOTE The outdoor temperature must be 60 F or higher before making adjustments to charge Comp...

Страница 18: ...ing to heating is desired 3 Set the room thermostat to the desired temperature TROUBLESHOOTING Ignition Control Error Codes The following presents probable causes of questionable unit operation Refer...

Страница 19: ...tem peratures This can be caused by a dirty filter excessive duct static insufficient air flow or a faulty limit Check filters total external duct static blower motor blower motor speed tap see wirin...

Страница 20: ...as frequently as necessary to keep the finned areas free of lint hair and debris Condenser Evaporator and Induced Draft Motors Bearings on the air circulating blower motor condenser mo tor and the com...

Страница 21: ...at the thermostat Wait a few minutes since any dislodged dust will alter the normal flame appearance Flames should be predominantly blue and directed into the tubes They should not be yellow They shou...

Страница 22: ...uck Closed 4 Flashes Thermal Protection Device Open 5 Flashes Flame Detected with Gas Valve Closed 6 Flashes Short Cycle Compressor Delay Cooling Only Amber Light Signal Refer to Abnormal Heating or C...

Страница 23: ...120 150 180 Circulator Blower HIGH OFF Seconds Gas Valve Igniter Induced Draft Blower Thermostat 0 15 22 27 52 0 30 LOW HIGH OFF LOW OFF ON HIGH OFF LOW HIGH OFF LOW Circulator Blower Compressor Outd...

Страница 24: ...PPLY ENTRANCE CONDENSATE DRAIN CONNECTION 3 4 NPT FEMALE 16 1 8 19 1 8 EVAPORATOR CONTROL PANEL ACCESS PANEL 4 3 4 B 7 15 16 16 B 5 1 2 1 3 8 16 2 3 4 A 18 7 16 FLUE EXHAUST 51 47 BLOWER ACCESS PANEL...

Страница 25: ...HES CHECK FOR SHORTS IN FLAME SENSOR WIRING CHECK GAS VALVE CHECK ROLLOUT LIMIT SW CHECK AUXILIARY LIMIT SW CHECK MAIN LIMIT SWITCH CHECK WIRING FOR SHORTS CHECK PRESSURE SWITCH PRESSURE SWITCH CLOSED...

Страница 26: ...on 4 Ton Min Filter Size 1 20 x 25 x1 1 25 x 25 x 1 1 25 x 25 x 1 2 20 x 20 x 1 2 20 x 20 x 1 Clearance in accordance with local installation codes the requirements of the gas supplier and the manufac...

Страница 27: ...X Not recommended for heating application NOTE The shaded area indicates ranges in excess of maximum external static pressure allowable when heating For satisfactory operation external static pressure...

Страница 28: ...28 CFM OUTPUT AND DIP SWITCH SETTINGS...

Страница 29: ...motor is hermetically sealed and does not require additional oiling Annual Inspection Qualified Servicer Only Your package unit should be inspected by a qualified install er or service agency at leas...

Страница 30: ...Type NG Natural Gas LP Liquid Propane Residential Package Outdoor Section ELECTRICAL Supply Voltage Measure L1 and L2 Voltage L1 L2 Compressor Amps Condenser Fan Amps PRESSURES TEMPERATURES Suction Ci...

Страница 31: ...31 THIS PAGE IS LEFT INTENTIONALLY BLANK...

Страница 32: ...in all product comments Please fill out the feedback form on one of the following links Amana Brand Products http www amana hac com about us contact us You can also scan the QR code on the right for...

Отзывы: