PRODUCT DESIGN

Thermostats:

The following Amana

® 

brand Thermostats are suggested for use with the AMH8 Furnace Models:

Filters:

Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or
CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty.

Refer to Minimum Filter Area tables to determine filter area requirement. 

NOTE:

 Filters can also be installed elsewhere in

the duct system such as a central return.

Upflow Filters

FURNACE INPUT

FILTER SIZE

TYPE

45M

160 in

2

permanent

70M

241 in

2

permanent

90M

320 in

2

permanent

115M

400 in

2

permanent

140M

370 in

2

permanent

45M

320 in

2

disposable

70M

483 in

2

disposable

90M

640 in

2

disposable

115M

800 in

2

disposable

140M

738 in

2

disposable

PERMANENT NOMINAL 600 F.M. FACE VELOCITY
DISPOSABLE NOMINAL 300 F.M. FACE VELOCITY

MINIMUM FILTER SIZES

Cabinet

Width

(in.)

Nominal

Filter Size

(in.)

Approx.

Flow Area

(in

2

)

Cabinet

Width

(in.)

Nominal

Filter Size

(in.)

Approx.

Flow Area

(in

2

)

All

16 x 25 x 1

400

14

12 x 25 x 1

300

17-1/2

14 x 25 x 1

350

21

16 x 25 x 1

400

24-1/2

20 x 25 x 1

500

Side Return(s)

Bottom Return 

Thermostat

Mech./Digital

Programmable

Cool

Heat

CHT-18-60

Mechanical

Yes

Yes

Yes

CH70TG

Digital

No

Yes

Yes

CHSATG

Mechanical

Yes

Yes

Yes

H20TWR

Mechanical

Yes

No

Yes

THERMOSTATS

Содержание AMH8

Страница 1: ...ts related companies and is used under license to Goodman Company L P Houston TX All rights reserved Copyright 2009 2010 Goodman Company L P Refer to Service Manual RS6610004 for installation operatio...

Страница 2: ...repair this unit without such background may result in product damage personal injury or death Goodman will not be responsible for any injury or property damage arising from improper service or servi...

Страница 3: ...and disposal of refrigerants introduced into this unit Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines These regulations may vary by j...

Страница 4: ...f the blower door is not in place Keep the blower access door in place except for inspection and maintenance This furnace is also equipped with a self diagnosing elec tronic control module In the even...

Страница 5: ...air as altitude increases The kit will provide the proper design certified input rate within the specified altitude range 2000 3000 4000 4500 5000 6000 7000 8000 US BURNER ORIFICE 44 55 44 55 45 56 4...

Страница 6: ...Blower Door Interlock Switch Integrated Control Module Transformer Circulator Blower 1 2 3 4 5 6 7 8 9 Upflow Horizontal 1 Tubular Heat Exchanger 2 Pressure Switch 3 Flue Pipe Connection 4 Induced Dr...

Страница 7: ...7 AMH8 MODELS A B AMH80453AX AMH80703AX 14 12 1 2 AMH80704BX AMH80903BX AMH80904BX 17 1 2 16 AMH80905CX AMH81155CX 21 19 1 2 AMH81405DX 24 1 2 23 All dimensions are in inches Alt Gas Inlet High Volta...

Страница 8: ...81405DX 0 60 013070142 PRESSURE SWITCH TRIP POINTS AND USAGE CHART SQUARE NOSE ROUND NOSE PRESSURE SWITCH TRIP POINTS AND USAGE CHART For installaions in Canada the AMH8 furnace is certified only to 4...

Страница 9: ...have an insulated Z bracket for use with one size smaller furnace All proper coil combinations are subject to being ARI rated with a matched outdoor unit Coil Matches Amana brand units using R22 and...

Страница 10: ...ILTER SIZE TYPE 45M 160 in2 permanent 70M 241 in2 permanent 90M 320 in2 permanent 115M 400 in2 permanent 140M 370 in2 permanent 45M 320 in2 disposable 70M 483 in2 disposable 90M 640 in2 disposable 115...

Страница 11: ...nace in Low Stage Low Heat Blower Low Heat Blower Call for Heat Call for Heat Safety Circuit Check Safety Circuit Check MODE DIP SWITCH TwinComfort Note This furnace is designed to be used with a sing...

Страница 12: ...0 140 000 Output Natural Gas BTUH 1 36 000 56 000 56 000 72 000 72 000 72 000 92 000 112 000 Output LP BTUH 32 000 48 000 48 000 64 000 64 000 64 000 80 000 96 000 A F U E 80 0 80 0 80 0 80 0 80 0 80...

Страница 13: ...19 56 913 57 892 58 847 829 818 792 728 LOW 1 5 758 741 741 733 699 677 649 626 HIGH 4 0 2134 2100 25 2042 25 1975 26 1883 28 1786 1700 1601 M H S 80704B MED 3 5 1668 31 1663 31 1656 31 1645 32 1616 3...

Страница 14: ...30 40 50 60 70 80 90 110 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 20...

Страница 15: ...CIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING 1 SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0 7 AMPS BLOWER PRIMARY LIMIT WH GR BK IGNITER SURFACE HOT PU RD 15 PIN PLUG C NO SWITCH PRESSURE BR S...

Страница 16: ...ANTICIPATORONROOMTHERMOSTATAT0 7AMPS BLOWER PRIMARYLIMIT WH GR BK IGNITER SURFACE HOT PU RD 15PINPLUG C NO SWITCH PRESSURE BR SENSOR FLAME BK WH ROLLOUTLIMITS RAPIDFLASHES REVERSED115VACPOLARITY VERIF...

Страница 17: ...CIR NEU K5 GAS VALVE HIGH LIMIT AUX LIMIT PRESSURE SWITCH FLAME SENSOR PROBE IGNITOR FP IGN GND MV MLV PS HLO HLI CIRCULATOR BLOWER XFMR HOT XFMR NEU 24 VAC TH RO1 RO2 R TR C Y G W COMPRESSOR CONTACTO...

Отзывы: