18
16400005
©2009 ACP Inc.
Troubleshooting Procedures (Electronic Dial Models)
CONDITION
CHECK
Check continuity of magnetron
Defective
magnetron
RESULT
No
Continuity
CAUSE
REMEDY
Replace
Outlet has
proper
voltage Fuse
does not
blow.
Display do not turn on
countdown
Malfunction of
secondary
interlock switch
Replace
Check continuity of
power supply cord
Open power
supply cord
No
Continuity
Replace
Defective touch
control circuit
Normal
Replace
CONDITION
CHECK
Check continuity of primary
interlock switch
Malfunction of
primary interlock
switch
RESULT
No
Continuity
CAUSE
REMEDY
Adjust or
replace
Oven lamp
does not turn
on
Check continuity of secondary
interlock switch
Malfunction of
secondary
interlock
switch
No
Continuity
Adjust or
replace
Check D.C. voltage being
supplied to RELAY (RY3) coil
Defective touch
control circuit
0 V
Replace
Faulty contacts of
RELAY (RY3) or
open relay coil
Approx.
15 VDC
Replace
Trouble 2: Oven does not start cooking, even though the dial is rotated.