Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
© 2005 Maytag Services
16026785
15
Illustration Component
Test
Procedure
Results
L
A
B
A1
B1
N
Spark module 4 + 0
(select models)
Test for voltage at terminals
L and N ...................................................
Polarity and ground.................................
120 VAC
Not subject to polarity.
L or N
Output Terminals
Spark module 4 + 0
(select models)
Test for voltage at terminals
L and N ...................................................
Polarity and ground.................................
120 VAC
Not subject to polarity
Holder orifice
Verify gas pressure (WCP).........................
Check orifice for debris...............................
4
"
Natural
10
"
LP/Propane
Clean as needed.
270° valve
Verify gas is supplied.
Orifice adjusted for Natural or LP.
Adjust set screw for simmer control............
Refer to LP/Nat. conversion instructions.
Spark switch
(select models)
Unplug switch harness at rear of range.
Test for continuity at wire terminals.
Switch in LITE position..............................
Switch in any other position ......................
120 VAC
Continuity
Infinite
Spark switch
(select models)
Unplug switch harness at rear of range.
Test for continuity at wire terminals.
Switch in LITE position.............................
Switch in any other position .....................
120 VAC
Continuity
Infinite
Sealed burner
Verify gas is supplied .................................
Check for obstructions or contamination
in burner ports ............................................
Gas present.
Clean/remove any foreign objects.
Check ignitor for bending/cracking.
Sealed burner
Verify gas is supplied .................................
Check for obstructions or contamination
in burner ports ............................................
Gas present.
Clean/remove any foreign objects.
Check ignitor for bending/cracking.
Venturi / Air shutter
Verify gas is supplied .................................
Shutter setting ............................................
Gas present.
Blue flame with no yellow tipping.
Содержание AGR5712BD Series
Страница 27: ...2005 Maytag Services 16026785 A 1 Appendix A...
Страница 37: ...2005 Maytag Services 16026785 A 11 Installation Instructions RV s only...
Страница 38: ...A 12 16026785 2005 Maytag Services Installation Instructions RV s only...
Страница 63: ...2005 Maytag Services 16026785 C 1 Appendix C...