25
RE220002 Rev. 6
Disassembly Procedures
To avoid risk of electrical shock, personal injury, or death,
disconnect power to unit and discharge capacitor(s)
before following any disassembly procedures.
WARNING
!
Blower Replacment
1.
Remove magnetron inlet duct.
2.
Remove blower motor ground lead screw from the
oven base.
3. Disconnect two blower motor wires.
4. Remove mounting screws and lift out blower
assembly. The left blower assembly (FS14 only) has
two mounting screws located toward the rear of the
oven. The right blower asseembly has two mounting
screws toward the rear of the oven and one mounting
screw near the high voltage transformer.
Right (Rear) High Voltage Transformer
Replacement
1. Lower the back panel to the service position.
2. Remove the right blower air duct and the magnetron
exhaust duct (FS14 only).
3. Disconnect the transformer leads.
4. Remove four transformer mounting screws.
Left (Side) High Voltage Transformer
Replacement
1. Lower the back panel to the service position.
2. Remove the left blower air duct and left blower
assembly.
3. Disconnect the transformer leads.
4. Remove two transformer mounting screws.
Component Module Panel Removal
Model VEND-10.000, .A, .B, .C
1. Remove the control panel assembly.
2. Locate the top and bottom release tabs on the panel
harness connector located above and to the rear of
the component module panel. Press the tabs against
the connector housing and pull the connector toward
the oven front to disconnect the connector.
3. Remove two interlock switch module screws and
remove the switch module. Do not disconnect wires
to the switch module.
4. Remove the nut at the top of the component module
panel. Pull the top of the panel away from the cavity
wall until it clears the stud.
5. Pull the component module panel toward the front of
the oven and lift up to separate the two tabs from
slots in the oven base.
6. Slowly pull the interlock switch module and
component module panel through the control panel
opening. Move wires around as required to clear the
opening.
NOTE: After replacement, perform interlock switch
module adjustment. Perform Radio Frequency
Leakage Test Procedures.