DELTA TAU WORKSTATION
990-828
21
Jogging Information:
Position
Information
Provides accurate information on the location of your axes.
Current Axis to Jog
The selected radio button determines which axis the
Jog+
and
Jog-
buttons operate on.
Jog Selected Axis
Will jog the currently selected axis.
Enable Fast
Jogging
If checked increases the slew rate of the currently selected axis.
Feedrate
The feed rate slider is a global control allowing the currently
programmed feed rate to be lowered manually using a multiplier. When
the feed rate slider is set to 100% (or multiplier of 1.0) all axes move
according to their programmed feed rates. At 50% (or 0.50) they move at
half their programmed speed. This affects jogging as well and is an
excellent way to fine tune a precision move when even the slow jog is too
fast. This slider is left in the 100% position during normal operation.
Содержание Delta