Congratulations on your purchase of a power system designed by AM Solar! We have assembled this kit to take the guess work out of putting together a 
complete solar solution. Now the fun begins - It's time for installation. Please read the guidelines below to help ensure a smooth project completion.

Stay safe

Remember that you will be working with both AC and DC power, so whenever possible avoid working with "live" components. Always use caution when working 
with electricity. When this guide is followed, you'll have a safe and successful installation. Be careful, not frightful - The installation can be fun when following 
these instructions and not cutting corners.

Keeping a realistic time frame for installation is important

This installation might take 4 to 5 days for an experienced AM Solar technician. So, establishing a realistic goal for completing 

the installation is helpful and avoids rushing aspects of the project. You'll want to stay consistent with your work beginning to 

end, without the need to rush.

Don’t rush the layout and planning of component placement

The design/layout part of your build is the most important thing you’ll do. Grab some chalk, cardboard, rope and a ball of string - We’re 

going to make some component placement templates. Use chalk to outline spots for smaller items such as breakers and the fuse panel. Use the string to 

make the small wire runs, rope for heavy gauge, and label them (tape and stickers works well). Then layout the all the components that fit the interior of your rig 
to prepare for installation.

Keep it organized

S

tay organized by making your work tidy and well planned. Read the included product guides / instructions and 

ABC

 (Always Be Checking). If you 

are installing and find that something was missed during your layout and planning and can't be installed correctly or safely, don't worry! Just 
backtrack to that stage in your layout design, and find an alternative placement before moving forward.

 

Making it last

No matter how long you plan on keeping this kit, it’s only going to be useful and have value if it's in good order. This equipment doesn’t react well to neglect 

or abuse. When planning and performing the installation, use proper technique and plan for the long run. Using duck tape to secure a part in place 

might be a good emergency fix, but you’ll want to start as “clean” as possible from the beginning.

Component Proximity

Always keep high current lines as short as possible. The battery to inverter cable should be under 10 feet, 5 feet would be ideal. If you are mounting all the 
equipment in a very small area, be aware of the distance between all "connection points" - If a component comes loose and shifts for any reason, you will want 
to ensure it will not result in components touching each other and possibly causing a short.

General Guidelines and Tips

99-TRLSIG 

Deluxe Upgrade

AM Solar Inc.

3555 Marcola Rd.

Springfield, OR 97477

541.726.1091

www.amsolar.com

Rev.20190813

Содержание Deluxe Upgrade 99-TRLSIG

Страница 1: ...99 TRLSIG Deluxe Upgrade Installation Guide AM Solar Inc 3555 Marcola Rd Springfield OR 97477 541 726 1091 www amsolar com Website Link Rev 20190813...

Страница 2: ...ch subsystem in the kit Complete bill of materials broken down by subsystem listing quantities part numbers and descriptions with QR codes to link data sheets for major components Detail of the Batter...

Страница 3: ...ll wire runs rope for heavy gauge and label them tape and stickers works well Then layout the all the components that fit the interior of your rig to prepare for installation Keep it organized Stay or...

Страница 4: ...eat time to schedule your installation work with the professionals at AM Solar Sturdy Ladder Hammer Crimper Hammer Heat Gun Wire Crimper Wire stripper Cable Cutter Multimeter Screwdriver Smartphone Dr...

Страница 5: ...26 1091 www amsolar com To 2nd Solar Panel 99 TRLSIG Deluxe Upgrade System Overview Main AC Panel SPS Transfer Switch Back of Solar Panel s with Rocker Foot Mounts Fuse Modified Zamp 100W Solar Panel...

Страница 6: ...xe Upgrade Bill of Materials AM Solar Inc 3555 Marcola Rd Springfield OR 97477 541 726 1091 www amsolar com Solar Panels Charge Controller Inverter 3000 Lithium Batteries Color Control Lithium Base Ki...

Страница 7: ...Used Cut and Cap Wire To Engine Battery DC Loads Red Post 93P RED TEMP BS FUSE MEGA 250A CABLE VT M8 1 CABLE 2GA 1 RED CABLE 18GA 1 YLW CABLE 4 0 1 BLK CABLE 4 0 1 BLK CABLE 18GA 2 GRY LUG 4 0 RING 3...

Страница 8: ...99 TRLSIG Deluxe Upgrade Lithium Control Board AM Solar Inc 3555 Marcola Rd Springfield OR 97477 541 726 1091 www amsolar com AM Solar Lithium Control Board Rev 20190813...

Страница 9: ...nc 3555 Marcola Rd Springfield OR 97477 541 726 1091 www amsolar com 50 TSFMB1 LUG 4 0 RING 3 8 Main AC Panel SPS BOX PD5500 LUG 4 0 RING 3 8 93H B3 4 93H R3 4 RJ45 PORT1 MAINS DETECTOR BLUE NOTE The...

Страница 10: ...N L2 Inverter Output Inverter Input L 1 N L2 SHORE IN Do Not Connect Shore Here L 1 N L2 99 TRLSIG Deluxe Upgrade SPS Wiring AM Solar s SPS Full Passthrough All the time Fuse Connect loose black 18g...

Страница 11: ...Panel Mounted Dimensions 39 56 x 19 88 x 1 38 MOUNTA 35 MOUNTA 35 MOUNTA 35 MOUNTA 35 MOUNTL 3 MOUNTL 3 MOUNTL T3 MOUNTL T3 FSTBLT TKNOB FSTBLT TKNOB FSTBLT TKNOB FSTBLT TKNOB FSWASH FLT 5 16 FSWASH...

Страница 12: ...7 Mode Leave on B 8 Alarm output Select Relay from the menu 2 Select BatteryProtect from VictronConnect 5 Select User defined from the Preset menu 7 Mode should be set to Relay mode 8 Alarm output Sel...

Страница 13: ...iciency Factor 98 12 Go back to settings enter Misc 13 Temperature Unit Fahrenheit 14 Aux Input User Option Temp 15 Exit from the device NOTE Only one phone can be connected to each device at a time B...

Страница 14: ...een Click on the 3 buttons to the right of the controller image and select Reset PIN Code 5 Click on the gear in the top right corner 6 Click on Battery 7 Click on the settings and adjust them accordi...

Страница 15: ...etwork picture 3 5 Enter a name for your network picture 4 Linking Each Device 1 Enter the Victron Connect App and click on a device 2 Go to Settings shown as a gear symbol in the top right picture 1...

Страница 16: ...is entered 4 The connection could take up to 1 minute to complete Ensure it displays connected when done You now have internet access to your display Be sure to remain within the wireless signal range...

Страница 17: ...d set date time 6 Go back to settings enter General then select reboot 7 Enter settings once rebooted then enter Services and turn on VRM two way communication 8 Go to Settings then enter System Setup...

Отзывы: