AM Solar Deluxe Upgrade 99-TRLSIG Скачать руководство пользователя страница 13

Programming the Battery Monitor

Programming / Commissioning Your System - The BMV-712 Smart Battery Monitor

Programming on the BMV-712 Battery Monitor: 

1. Download “Victron Connect” from the App Store (picture 1).

2. Turn on your Phone’s Bluetooth, and get as close as possible to your Victron 

Component(s).

3. Open the Victron Connect app, and after it takes a moment to scan it will 

recognize your BMV-712.

              NOTE: 

If your device is not shown, it is probably signal interference. Try 

closing the app and moving to a different location before re-entering the app in a 
location that can pick up the BMV signal.

4. Select the BMV-712 on the Device List (picture 2).

5. Press the gear icon in the top right corner (picture 3).

6. Enter “Battery Settings” and change the values below (similar to picture 4):

7.

Changing Battery Capacity

: Enter the number of Ah of your entire battery bank

8.

Charge Voltage

: 13.9

9.

Tail Current: 

 2%

10.

Peukert Exponent:

  1.1

11.

Charge Efficiency Factor:

 98%

12. Go back to settings, enter “Misc”

13.

Temperature Unit:

 Fahrenheit

14.

Aux Input

: User Option (“Temp”)

15. Exit from the device.

                 NOTE: 

Only one phone can be connected to 

each device at a time. Be sure to completely 

disconnect and close the app to log out

from the device.

Program Settings for Lithium Batteries 

Battery Capacity

:  Enter the total battery capacity in Amp Hours.

Charge Voltage

: 13.9

Tail Current

:  2%

Peukert Exponent

:  1.1

Charge Efficiency Factor

:  98%

Temperature Unit

:  “CELC” (Celsius) or “FAHR” Fahrenheit

Aux Input

:  User Option (“Temp” works best)

We recommend you interface with the BMV-712 through the Victron app on your phone, and 
change the settings from there.

 

The app is named “VictronConnect”. Ensure your Bluetooth 

is enabled before entering the app. Once inside the app you will see your BMV-712 
displayed, click on it to change the applicable settings:

NOTE: To change the PIN code from the app, go back to the device list page in the app. 
Click on the three circles to the right of your device, and select “Reset PIN code”.

1

2

3

4

AM Solar Inc.

3555 Marcola Rd.

Springfield, OR 97477

541.726.1091

www.amsolar.com

Rev.20190813

Содержание Deluxe Upgrade 99-TRLSIG

Страница 1: ...99 TRLSIG Deluxe Upgrade Installation Guide AM Solar Inc 3555 Marcola Rd Springfield OR 97477 541 726 1091 www amsolar com Website Link Rev 20190813...

Страница 2: ...ch subsystem in the kit Complete bill of materials broken down by subsystem listing quantities part numbers and descriptions with QR codes to link data sheets for major components Detail of the Batter...

Страница 3: ...ll wire runs rope for heavy gauge and label them tape and stickers works well Then layout the all the components that fit the interior of your rig to prepare for installation Keep it organized Stay or...

Страница 4: ...eat time to schedule your installation work with the professionals at AM Solar Sturdy Ladder Hammer Crimper Hammer Heat Gun Wire Crimper Wire stripper Cable Cutter Multimeter Screwdriver Smartphone Dr...

Страница 5: ...26 1091 www amsolar com To 2nd Solar Panel 99 TRLSIG Deluxe Upgrade System Overview Main AC Panel SPS Transfer Switch Back of Solar Panel s with Rocker Foot Mounts Fuse Modified Zamp 100W Solar Panel...

Страница 6: ...xe Upgrade Bill of Materials AM Solar Inc 3555 Marcola Rd Springfield OR 97477 541 726 1091 www amsolar com Solar Panels Charge Controller Inverter 3000 Lithium Batteries Color Control Lithium Base Ki...

Страница 7: ...Used Cut and Cap Wire To Engine Battery DC Loads Red Post 93P RED TEMP BS FUSE MEGA 250A CABLE VT M8 1 CABLE 2GA 1 RED CABLE 18GA 1 YLW CABLE 4 0 1 BLK CABLE 4 0 1 BLK CABLE 18GA 2 GRY LUG 4 0 RING 3...

Страница 8: ...99 TRLSIG Deluxe Upgrade Lithium Control Board AM Solar Inc 3555 Marcola Rd Springfield OR 97477 541 726 1091 www amsolar com AM Solar Lithium Control Board Rev 20190813...

Страница 9: ...nc 3555 Marcola Rd Springfield OR 97477 541 726 1091 www amsolar com 50 TSFMB1 LUG 4 0 RING 3 8 Main AC Panel SPS BOX PD5500 LUG 4 0 RING 3 8 93H B3 4 93H R3 4 RJ45 PORT1 MAINS DETECTOR BLUE NOTE The...

Страница 10: ...N L2 Inverter Output Inverter Input L 1 N L2 SHORE IN Do Not Connect Shore Here L 1 N L2 99 TRLSIG Deluxe Upgrade SPS Wiring AM Solar s SPS Full Passthrough All the time Fuse Connect loose black 18g...

Страница 11: ...Panel Mounted Dimensions 39 56 x 19 88 x 1 38 MOUNTA 35 MOUNTA 35 MOUNTA 35 MOUNTA 35 MOUNTL 3 MOUNTL 3 MOUNTL T3 MOUNTL T3 FSTBLT TKNOB FSTBLT TKNOB FSTBLT TKNOB FSTBLT TKNOB FSWASH FLT 5 16 FSWASH...

Страница 12: ...7 Mode Leave on B 8 Alarm output Select Relay from the menu 2 Select BatteryProtect from VictronConnect 5 Select User defined from the Preset menu 7 Mode should be set to Relay mode 8 Alarm output Sel...

Страница 13: ...iciency Factor 98 12 Go back to settings enter Misc 13 Temperature Unit Fahrenheit 14 Aux Input User Option Temp 15 Exit from the device NOTE Only one phone can be connected to each device at a time B...

Страница 14: ...een Click on the 3 buttons to the right of the controller image and select Reset PIN Code 5 Click on the gear in the top right corner 6 Click on Battery 7 Click on the settings and adjust them accordi...

Страница 15: ...etwork picture 3 5 Enter a name for your network picture 4 Linking Each Device 1 Enter the Victron Connect App and click on a device 2 Go to Settings shown as a gear symbol in the top right picture 1...

Страница 16: ...is entered 4 The connection could take up to 1 minute to complete Ensure it displays connected when done You now have internet access to your display Be sure to remain within the wireless signal range...

Страница 17: ...d set date time 6 Go back to settings enter General then select reboot 7 Enter settings once rebooted then enter Services and turn on VRM two way communication 8 Go to Settings then enter System Setup...

Отзывы: