The SU3000 offers the following user-configurable operational modes. Refer to the
SU3000 User Guide
for more information on
SU3000 operating modes and configuration instructions.
There is a power key switch on the end cabinet on the secured side of
all master and center cabinets.
1. Turn on AC power using the power key switch [Figure 25]. The
power-up cycle will take less than one minute to complete.
2. After the power-up sequence has completed, the SU3000 barrier
arms will move to the closed (Home) position and the SU3000
will enter into Controlled Passage mode in both the entry and exit
directions.
Fig. 25
Barrier arms are pre-aligned at the factory. However, they may need
slight adjustment after installation. Refer to Appendix A on Page 29
for instructions on setting the barrier arm Home Position.
The keys to power the turnstile ON/OFF are packaged in the hardware
box that was shipped with the turnstile.
Powering On
Power Key Switch
Operating Modes
NOTE
NOTE
OFF
ON
The barrier arms are up, securing the turnstile. Upon receipt of an authorization signal from an access control system the barrier
arms move down to the open position, allowing a single passage in the authorized direction. The barrier arms return to the closed
position after the user has passed through the turnstile or the time frame allowed for an entry to occur has expired.
The barrier arms are down, providing a barrier-free passageway. The barrier arms will not raise and secure the turnstile unless an
unauthorized passage is attempted. Normally Open mode should be used only in select applications.
The barrier arms remain down at all times allowing the SU3000 to function as an optical (barrier free) access control turnstile.
Normally Closed
Normally Open
Barrier Disabled