EDM Installation and Maintenance Instructions
Troubleshooting
Symptoms
Possible Cause
Possible Solution
• Turnstile does not
boot up.
• No primary power to the turnstile.
• Fuse has blown.
• 24v power supply not functioning.
• Verify the power is ON at the circuit breaker.
• Inspect fuse on primary power terminal block.
If blown, contact Alvarado for replacements.
• Meter power supply output. If 24v is not
present, replace power supply.
• Turnstile fans are on but no
Open / Close or Status Lights
and arm will not lock back
into place
• Fuse may have blown.
• Test F3 fuse on 10-1272 board for continuity.
• Test F2 fuse on 13-0327 board for continuity
If failed, contact Alvarado for replacements.
• Open/Close or Status Lights
are dim.
• Light boards are unplugged
• Fuse may have blown.
• Test F2 fuse on 10-1271 board for continuity.
• Test F1 fuse on 13-0327 board for continuity.
If failed, contact Alvarado for replacements.
• Arms do not rotate on boot
up.
• Fuse may have blown.
• Connectors came loose.
• Test F2 fuse on 10-1272 board for continuity.
• Test F3 fuse on 13-0327 board for continuity.
If failed, contact Alvarado for replacements.
• Inspect the J7/J8 connectors on 13-0327
board. Ensure both are properly secured.
• Arm does not lock into
position upon boot up.
• Emergency Override activation state
(N.O or N.C) is not set accordingly.
• Confirm building requirements. If a N.C
contact is required, insert a jumper between
ALRRST and GND on the J4 input terminal.
• Valid credentials do
not activate turnstile.
• Access control leads connected to
wrong terminals.
• Verify access control leads connect to the
appropriate terminals.
See terminal listing on Page 12.
• Remove access control leads and use test
buttons to simulate activations. If test buttons
do not activate, replace control board. See
Page 11 for button location.
• Turnstile shakes when a
passage is completed.
• Anchor bolts are loose.
• Check anchor bolts. If loose, tighten bolts
to 20 ft-lbs using a torque wrench.
• Arm does not fully return to
home position
• Home position needs calibration.
• Re-home the arms back to correct position.
See Appendix A on Page 25.
• Arms continue to rotate
after a passage.
• Double activation provided.
• Advise patrons to swipe their credentials
only once to prevent double activations.
• Drop arm does not lock
back into position.
• Foreign matter stuck in drop-arm
mechanism.
• Drop arm solenoid is defective.
• Ensure drop-arm mechanism is free of
debris.
• Power on turnstile, lift arm to lock position.
If it does not lock into position, replace the
drop-arm solenoid.
Contact Alvarado for replacement components.