EDM Installation and Maintenance Instructions

J5 Output Contacts

Pin #

Pin  
Name

Function 
Description

Contact 
Type

Function & Behavior 
Description

Pin #

Pin  
Name

Function 
Description

Contact 
Type

Function & Behavior 
Description

1

ENTUCX

Exit Passage 

Count

MDC

Counts the number of 

passages in the exit direction.

1

EXTPAS

Free 

Passage 

CCW

SDC

Sets the turnstile to Free 

Passage mode in the CCW

direction.

2

ENTACX

Entry 

Passage 

Count

MDC

Counts the number of 

passages in the entry 

direction.

2

EXTREJ

Bad Card 

CCW

MDC

Illuminates the CCW direction 

RED User Status Icon for 2 

seconds.

3

GNDX

Ground

N/A

Common input ground signal.

3

EXTACC

Good Card 

CCW

MDC

Opens the turnstile for one 

authorized passage until 

passage occurs or timeout.

4

4

EMROVR

Emergency 

Override

SDC 

(N.O. or 

N.C.)

Drops the arms for free egress.

 

Arms remain down and turnstile  

is inactive until SDC is removed, 

or contact is reestablished 

if N.C. setting is enabled.

(Typically used for fire alarm

or life safety systems.) 

5

5

GND

Ground

SDC

Common input ground signal.

6

6

BARDISABLE Barrier 

Disable 

Mode

7

7

ALRRST

SDC

Changes the EMROVR contact  

from N.O to N.C.

8

8

ENTSER

No Passage 

Mode CCW

SDC

Sets the turnstile to No 

Passage mode in the CCW

direction.

9

9

ENTOVR

N/A

N/A

Not available in the EDM.

10 GND

Ground

N/A

Common input ground signal

10

11 ENTCLS

No Passage 

Mode CW

SDC

Sets the turnstile to No 

Passage mode in the CW

direction.

11

12 ENTPAS

Free 

Passage 

Mode CW

SDC

Sets the turnstile to Free 

Passage mode in the CW

direction.

12

13 ENTREJ

Bad Card 

CW

MDC

Illuminates the CW side 

RED User Status Icon for 2 

seconds.

13

14 ENTACC

Good Card 

CW

MDC

Opens the turnstile for one 

authorized passage until 

passage occurs or timeout.

14

15 GND

Ground

N/A

Common input ground signal.

 

Emergency 

Override State

Arm drops to allow for 

barrier free operation. 

J4 Terminal Block Input Contacts

MDC

Control Board Description (Cont.)

J5 Terminal Block Output Contacts 

J4 Input Contacts

Pin #

Pin  
Name

Function 
Description

Contact 
Type

Function & Behavior 
Description

Pin #

Pin  
Name

Function 
Description

Contact 
Type

Function & Behavior 
Description

1

ENTUCX

CCW 

Passage 

Count

MDC

for each rotation in the CCW 

direction.

1

EXTPAS

Free 

Passage 

Exit

SDC

Sets the turnstile to Free 

Passage mode in the exit 

direction.

2

ENTACX

CW

Passage 

Count

MDC

for each rotation in the CW

direction.

2

EXTREJ

Bad Card 

Exit

MDC

Illuminates the exit direction 

RED User Status Icon for 2 

seconds.

3

GNDX

Ground

N/A

Common input ground signal.

3

EXTACC

Good Card 

Exit

MDC

Opens the turnstile for one 

authorized passage until 

passage occurs or timeout.

Emergency 

Override

SDC 

(N.O. or 

N.C.)

**Opens the barriers toward 

the unsecured side; barriers 

remain open and turnstile is 

inactive until SDC is removed, 

or contact is reestablished 

if N.C. jumper is enabled. 
or life safety systems.)

Ground

SDC

Common input ground signal.

Barrier 

Disable 

Mode

N/A

**Disables the barrier.

**

SDC

Sets the EMROVR contact to 

N.O or N.C.

No Passage 

Mode Exit

SDC

Sets the turnstile to No 

Passage mode in the exit 

direction.

N/A

N/A

Not available in the EDM.

Ground

N/A

Common input ground signal

No Passage 

Mode Entry

SDC

Sets the turnstile to No 

Passage mode in the entry 

direction.

Free 

Passage 

Mode Entry

SDC

Sets the turnstile to Free 

Passage mode in the entry 

direction.

Bad Card 

Entry

MDC

Illuminates the entry side 

RED User Status Icon for 2 

seconds.

Good Card 

Entry

MDC

Opens the turnstile for one 

authorized passage until 

passage occurs or timeout.

Ground

N/A

Common input ground signal.

Outputs a dry-contact closure

Outputs a dry-contact closure

Identifying Rotation Direction

Clockwise (CW):
Turnstile arms rotate in a clockwise direction when viewed 

looking down from behind the cabinet.

Counter-Clockwise (CCW):
Turnstile arms rotate in a counter-clockwise direction when 

viewed looking down from behind the cabinet.

CW

Secured 

Side

CCW

Unsecured 

Side

Fig. 10

Orientation shown for a right-handed cabinet.

Adjacent Barrier or Turnstile

Содержание EDM

Страница 1: ...Company Inc 12660 Colony Street Chino CA 91710 Telephone 1 909 591 8431 Fax 1 909 628 1403 support alvaradomfg com www alvaradomfg com PUD4146R1 0 Installation and Maintenance Instructions EDM Motoriz...

Страница 2: ...wering On 15 Post Installation Functions Check 15 Loss of Power Operation 15 Testing Turnstile Functionality 16 Test Key Override Operation 18 Test the Local Counter Optional 19 Remote 3 Way Switch Op...

Страница 3: ...manual Safety Precautions The following symbols are used throughout the manual to highlight important information and potential risks when installing servicing or using the turnstiles covered in this...

Страница 4: ...lear RTV Silicone Tools Required Tools required for Portable Base Turnstile installations are located in Appendix B Portable Base Turnstile on page 26 NOTE Keys per turnstile Turnstile Lid Keys Qty 2...

Страница 5: ...urnstiles certain sections of this manual may not be applicable to your installation This manual covers the physical installation process for the EDM Motorized Waist High Turnstile At the end of this...

Страница 6: ...barrier Fig 1 Stub up conduit in accordance with local electrical codes Fig 2 Always verify the layout of the turnstile s before anchor installation Fig 2 Fig 1 Space Conduit Requirements Adjacent Ba...

Страница 7: ...rt alvaradomfg com 1 909 591 8431 Page 7 EDM Installation and Maintenance Instructions Space Conduit Requirements Cont Fig 3b L Fig 3a Fig 3c NOTE EDM Square cabinet shown Refer to Appendix C on page...

Страница 8: ...ion Primarypowerisfuseprotected 3A 250VAC slo blo 24VDC 12VDC and 5VDC is fuse protected The 24VDC power supply is rated for lightning and industrial surges per IEC 61000 4 2 5 6 8 11 It is the instal...

Страница 9: ...layout 4 Transfer four 4 anchor locations to the floor Fig 5 5 Move the turnstile to the side 6 Using a hammer drill fitted with a 5 8 concrete bit drill each anchor hole to a depth of 3 76 2mm 7 Usi...

Страница 10: ...iring Instructions Use a licensed electrician for the following steps and adhere to all applicable local codes MAKE SURE PRIMARY POWER IS TURNED OFF AT THE BREAKER WARNING Power Button 110VAC version...

Страница 11: ...t duration is 1 second or less to support rapid throughput in high volume applications Outputs J5 Terminal Block Signal outputs are available from the EDM s I O output terminal block Outputs are norma...

Страница 12: ...Mode CW SDC Sets the turnstile to No Passage mode in the CW direction 12 ENTPAS Free Passage Mode CW SDC Sets the turnstile to Free Passage mode in the CW direction 13 ENTREJ Bad Card CW MDC Illumina...

Страница 13: ...e I O input terminal block are provided below Instructions on using the key override is provided on page 18 NOTE Ensure power to the turnstile is OFF when wiring the I O Terminal Blocks Setting Contro...

Страница 14: ...Direction CCW Direction Setting No Passage Mode I O Input J4 Terminal Block EXTPAS 1 EXTREJ 2 EXTACC 3 EMROVR 4 GND 5 BDISABLE 6 ALRRST 7 ENTSER 8 ENTOVR 9 GND 10 ENTCLS 11 ENTPAS 12 ENTREJ 13 ENTACC...

Страница 15: ...checks to verify the turnstile is performing properly Function checks are included for optional accessories i e User Status lights Open Close lights Local Counters etc and may not be applicable to you...

Страница 16: ...h arms in the direction of passage Arms will rotate small amount in the direction of passage and then lock Buzzer will sound Arms reset in two seconds Optional Accessories User Status lights change fr...

Страница 17: ...moved Optional Accessories User Status and Open Close lights turn off Impact Provide an activation Begin to rotate the arms in the passage direction and block with either your hand or leg Buzzer sound...

Страница 18: ...g 12 1 Default position CENTER sets turnstile to Controlled Passage mode Verify the arms are locked in the appropriate direction and unlock with valid credentials If you have User Status lights instal...

Страница 19: ...turnstile arm generates a count One counter is required per rotation direction 1 Place the turnstile in Free Passage Mode using the Key Override 2 Rotate the turnstile arms several times Verify that...

Страница 20: ...Controlled Mode ready for a valid card presentation Green When the green light illuminates the turnstile is unlocked and ready for passage The access control system has provided the turnstile control...

Страница 21: ...minal on the control board Refer to page 11 for location A Use a USB to Serial converter cable if the laptop does not have a serial port 3 Double click the utility icon to launch the utility This will...

Страница 22: ...ons Default 115 14 Motion Profile This is the algorithm used to control the arm movement speed Do Not Change 15 Return Arm Time Sets the length of time required to return arms to home position if moto...

Страница 23: ...g any commercially available stainless steel cleaner or polish If a heavier scratch mark is apparent a metal blend and finish pad by 3M Company or equivalent may be used followed by a stainless steel...

Страница 24: ...s on 13 0327 board Ensure both are properly secured Arm does not lock into position upon boot up Emergency Override activation state N O or N C is not set accordingly Confirm building requirements If...

Страница 25: ...e blinking indicating normaloperation mode 2 Press and hold the Test Mode button for 2 seconds The D2 LED will be lit solid This indicates the turnstile is in Test Mode Fig 16a 3 Hold arm and rotate 3...

Страница 26: ...guide rail into the support posts and tighten the four 4 set screws using a 1 8 Allen wrench Fig B1 B2 3 To maneuver the turnstile Starting with the two 2 wheels on the cabinet side place foot on the...

Страница 27: ...bushing 1 and the chuck 2 over the cable White chuck a 6 0 11 0 mm 0 236 0 433 Black chuck b 9 5 15 0 mm 0 374 0 59 VDE 9 5 14 0 mm 0 374 0 551 Prepare the cable as shown Cable O D 6 0 15 0 mm 0 236 0...

Страница 28: ...lation process for Portable AC Powered turnstiles Proceed to the Functions Check on pg 16 17 AC Inlet Installing Neutrik Connector to AC Cord cont Fasten bushing by means of a fork wrench 7 8 SW 22 mi...

Страница 29: ...D4146R1 0 For Assistance support alvaradomfg com 1 909 591 8431 Page 29 EDM Installation and Maintenance Instructions Portable Base Plan Elevation and Footprint Drawing EDM Square Fig B6 Fig B7 Fig B8...

Страница 30: ...e 30 For Assistance support alvaradomfg com 1 909 591 8431 PUD4146R1 0 EDM Installation and Maintenance Instructions Appendix C Plan Elevation and Footprint Drawing EDM Bullnose Fig C1 Fig C2 L C Fig...

Страница 31: ...146R1 0 For Assistance support alvaradomfg com 1 909 591 8431 Page 31 EDM Installation and Maintenance Instructions Fig C4 Fig C5 C L Fig C6 Portable Base Plan Elevation and Footprint Drawing EDM Bull...

Страница 32: ...32 For Assistance support alvaradomfg com 1 909 591 8431 PUD4146R1 0 EDM Installation and Maintenance Instructions Revision History Revision Date Author Description 1 0 10 25 17 C Maynez Original Docu...

Страница 33: ...PUD4146R1 0 For Assistance support alvaradomfg com 1 909 591 8431 Page 33 Page left intentionally blank...

Страница 34: ...1710 Telephone 909 591 8431 Fax 909 628 1403 support alvaradomfg com www alvaradomfg com 2017 Alvarado Manufacturing Company Inc This work may not be reproduced published or redistributed in whole or...

Отзывы:

Похожие инструкции для EDM