NOTE
Install the turnstile on a 6' x 6' (min.) level concrete slab. The slab must
be a minimum of 4" thickness. The turnstile may only be installed on
concrete. Do not install the turnstile on asphalt.
DIMENSIONS SHOWN ARE FOR MST-3 and MST-6X MODELS. SEE
APPENDIX A-D FOR OTHER MODELS.
NOTE
The turnstile is rated for both indoor and outdoor use.
Installation Locations
1.
Determine where the turnstile will be installed.
Consider the overall footprint size of the unit when
determining the installation location (Figure 1).
Once the installation location has been determined,
use a chalk line to mark the centerline of the
turnstile.
NOTES
Default entry rotation is counterclockwise.
Confirm correct entry direction prior to
installation.
Alvarado recommends that the minimum
installation width required be 64".
62.00"
(1575mm)
54.00"
(1372mm)
2.
Determine and mark the centerline location for the
OV, Roto, and Yoke (Figure 2).
NOTE
The overall height of the MST is 91.5". However, an
additional 3" of clearance must be added for service
and maintenance.
If desired, installers can stub up the power conduit at
the intersection of the turnstile centerline and the OV
centerline. Power may also be routed directly into the
top channel (Figure 26).
Mark all center lines prior to installation.
Fig. 1
Fig. 2
Roto Centerline
29.63"
(752mm)
30.0"
(762mm)
CL
CL
O
N
Yoke Centerline
Entry Side
(Unsecured)
Exit Side
(Secured)
31.5"
(800mm)
30.5"
(775mm)
OV Centerline
30.0"
(762mm)
29.63"
(752mm)