EPH-N00-06003
5-20-97
Page 8 of 11
12
- 790 DOORS ONLY
13
- 790 DOORS ONLY
14
- 790 DOORS ONLY
Insert the two #10-24 x 7/16" square head
set screws [X] into the threaded holes in the pivot
blocks in the top and bottom rails of the glazed
door panel [M]. Position the pivot pins 1 1/2" from
the pivot side of the door (the side opposite the
magnetic strip). Tighten the set screws just enough
to prevent the pivot blocks from moving (finger
tight plus a quarter turn). A 3/16" wrench (not
supplied by A
LUMAX
) will fit the set screw heads.
Press the white nylon spacer [Y] over the bottom
pivot pin on the door panel.
Insert the two nylon pivot bushings [AA] into
the pivot holes in the head and curb fillers [R].
Lift the door panel [M] and insert the top pivot pin
into the pivot bushing in the header filler. Hold the
door vertical and insert the bottom pivot pin into the
pivot bushing in the curb filler. It may be necessary
to remove the header retaining screws and raise the
header slightly to install the door.
When the door has been set into place, snap the
security washer [BB] over the top pivot pin to hold
the upper pivot bushing in place and prevent
accidental dislodging of the door.
Cut the drip rail [S] to the length of the bottom
rail minus 11/16". Clean the bottom door rail and the
drip rail thoroughly to ensure proper adhesion. Unroll
the double stick tape [W] and carefully apply it to the
back of the drip rail (do not peel the tape backing yet).
Insert the tapered drip vinyl [U] into the drip rail.
Position the drip rail flush with the bottom and pivot
side of the door panel [M], then raise the strike side
until the bottom edge of the drip vinyl is parallel to the
curb [A]. Mark the location of each end of the drip rail.