background image

4

Pre-Installation

Hardware Registration

Before installation of your BAT-WIFI, it must be registered at www.alarmdealer.com. 
Here are the steps needed to register your hardware:

 

• Log into www.alarmdealer.com with the dealer login information that was emailed to you.

 

• Click Create Account Wizard

 

• Follow the 4-Step Wizard

Installation Guide

General Considerations

 

• Before installation, your BAT-WIFI must be setup using the dealer branded portal www.alarmdealer.com.

 

•  The BAT-WIFI should be installed securely in the supplied plastic housing, and be mounted beside your 

alarm control panel.

 

•  Where available, proximity to the hard-wired Ethernet Internet connection should be taken into 

consideration when routing wires.

 

•  Choose a location with good reception by monitoring the BAT- WIFI signal strength LEDs with a  

pre-wire power up.

 

• The BAT-WIFI must be completely powered down before starting the wire up.

 

•  Programming is simple using the alarm control panel. Written instructions are included in the  

“Wiring & Programming” section of this manual.

AP Configuration Tool QuickStart Guide

An easy to use QuickStart Guide has been designed to make the BAT WiFi easily join the customer’s WiFi 
Network.

Connecting to a Wireless Network (AP Configuration)

The BAT-WIFI has an AP Configuration Tool which is designed to assist with ensuring the BAT-WIFI joins a 
wireless network easily.

The following steps should be followed:

 

1. Power up the BAT-WIFI at the alarm panel.

 

2.  Open your smartphone or laptop and search for Wireless Connections 

a.  In the list of WiFi connections you should see one labeled: IPD-CFG-AP-XX-XX-XX. The last six digits 

will match the MAC address of your WiFi device. If not, try moving your BAT-WIFI to a different 
location for better reception.

 

3. Connect to the WiFi Network: IPD CFG-AP-XX-XX-XX

 

4.  After you are connected to your smartphone or laptop. Open a web browser and type in the following IP 

Address: 192.168.100.1

 

5. Once you have connected to the above IP Address it will launch the AP Configuration Tool.

 

6.  Next you will click on “Scan for Wireless Networks”. This will populate a list of all available wireless 

networks in your area.

 

7.  Find the customers Wireless Network and click on it. If security credentials are required, you will be 

prompted to enter them.

 

8. You should now be connected to the customers WiFi Network!

Содержание BAT WIFI

Страница 1: ...alula net BAT WIFI SKU IPD BAT WIFI Wi Fi Internet Alarm Communicator PRODUCT MANUAL...

Страница 2: ...1 Product Manual BAT WIFI...

Страница 3: ...t Number Location 2 Enter 13 for Contact ID Programming for TELCO use on Vista Section Universal WiFi BAT as Sole Communicator 41 Enter Phone Number 43 Enter Account Number 193 Enter 1 0 Enable to tur...

Страница 4: ...Quick Reference 2 Getting Started 3 Pre Installation 3 Installation Guide 3 DSC Panel Wiring and Programming 6 DSC PC Link Connection 7 DSC Programming Charts 8 Honeywell Vista Panel Wiring and Progr...

Страница 5: ...art Guide An easy to use QuickStart Guide has been designed to make the BAT WiFi easily join the customer s WiFi Network Connecting to a Wireless Network AP Configuration The BAT WIFI has an AP Config...

Страница 6: ...a WiFi router Reset the Wireless Network AP Configuration Tool Locate the button labeled SW1 on the top left of the board When this button is pressed 3 times in a row it causes the device to perform...

Страница 7: ...nable 193 with 1 0 to turn on Address 20 GE Panels Automatically enroll to Keypad Slot Expansion 240 once you enter and exit programming Troubleshooting Diagnostic Information Under normal operation t...

Страница 8: ...keypad functionality works through www alarmdealer com www setup alarmdealer com or the Alula mobile app Ensure that alarm signals reach your central station Wiring Programming for Popular Panels The...

Страница 9: ...8 DSC Keybus Tip Ring Wiring DSC Panel Wiring and Programming...

Страница 10: ...9 DSC PC Link connection This allows for remote downloader functionality with Alula s Universal Downloader uDownloader software DSC PC Link Wiring...

Страница 11: ...n dialer capture mode Section BAT as Sole Communicator BAT as Fail over w Add l Communication Device BAT as Dual Reporting w Add l Communication Device Code Summarization 015 Disable Option 7 If GSM D...

Страница 12: ...on 2 and alternate communications option 5 375 Enable Option 1 Enable Option 1 5 Enable Option 1 2 5 Options to turn on off maintenance for telephone 1 option 1 telephone 2 option 2 and alternate comm...

Страница 13: ...12 Vista Keybus Tip Ring Wiring Vista Panel Wiring and Programming...

Страница 14: ...nother Communication Device for Fail over For Dual Reporting Code Summarization 29 Enter 1 Enter 1 Enter 1 This enables GSM The BAT Emulates a GSM 42 N A Enter Central Station Receiver Number Enter Ce...

Страница 15: ...eral Concept Programming on GE NetworX Section BAT as Sole Communicator Code Summarization Device 0 Location 0 Enter the Phone Number Device 0 Location 1 Enter Account Number Device 0 Location 2 Enter...

Страница 16: ...ric Alarm Panel Programming Program the panel Phone Number into the panel Program the Customers Account Number into the panel Program Reporting codes into the panel Program panel to transmit in Contac...

Страница 17: ...ded A programmable output on the alarm panel will be used to signal to the BAT Y Tx terminal that the panel has entered Arm Disarmed State The Z1 output on the BAT WIFI will be used as a keyswitch con...

Страница 18: ...panel installation manual for details on your specific installation Ademco Typical 56 program zone as type 77 80 Menu LED Outs Program 17 and 18 zone type 78 and 79 DSC PowerSeries Typical Section 001...

Страница 19: ...5PCN 2 6 Vista 15PSIA 4 0 Vista 20P 2 6 Vista 20PCN 2 6 Vista 20PI 5 Vista 20PS 2 6 Vista 20PSIA 4 0 Vista 21IP 1 0 Vista 21IPSIA 1 0 Vista 32FB 1 0 First Alert FA130 2 6 First Alert FA148 2 6 First A...

Страница 20: ...ve should function properly as long as it transmits Contact ID through Tip Ring If the panel has the ability to use a Dedicated Open Zone that acts as a Keyswitch you can Arm Disarm from the Website o...

Страница 21: ...xternally provided 12v DC Typical Current 130 mA Max Current 185mA Environmental Temperature Range 30 to 70 C 22 to 158 F Humidity 0 to 95 non condensing Physical Height 7 05 inches Width 4 45 inches...

Страница 22: ...21...

Страница 23: ...la 1402 Heggen St Hudson WI 54016 888 88 ALULA All product and company names are trademarks or registered trademarks of their respective holders Use of them does not imply any affiliation with or endo...

Отзывы: