background image

13

Vista Panel Programming

All Control Panels must have a Phone Number in the Panel and an Account Number in the Panel. As long as 
your Reporting Codes are in the Panel and are transmitting in Contact ID it will send signals.

Programming when using TELCO (Recommended): Programming on Vista (BAT WIFI as Sole Communicator):

Section

For BAT as Sole 

Communicator

Code Summarization

41

Enter Phone Number

43

Enter Account Number

49

Enter 5

For All Communications to BAT

54

Enter 0

No Delay Between Communicators

55

Enter 0

Phone Line Communicates First

65 & 66

Enter 1

If you want Opening/Closing Reports

193

Enter 1, 0

Enable to turn on Address 20

Programming when ONLY using Keybus to send Signals (Not Recommended): Vista Programming for 
Communications - GSM Emulation:

Section

For BAT as Sole 

Communicator

For BAT in use with 

another Communication 

Device for Fail over

For Dual Reporting

Code Summarization

*29

Enter 1

Enter 1

Enter 1

This enables GSM. The 

BAT Emulates a GSM.

*42

N/A

Enter Central Station 

Receiver Number

Enter Central Station 

Receiver Number

Secondary Phone 

Number.

*43

Enter Account Number

Enter Account Number

Enter Account Number

This is the central station 

account number.

*49

Enter 5

Please refer to panel 

manual for your 

particular application 

requirements

Please refer to panel 

manual for your 

particular application 

requirements

Dual Reporting; Setting 

to 5 sends all reporting 

to both primary and 

secondary.

*54

Enter 0

Enter 2

Enter 0

The time it takes for 

the communicator to 

switch from primary to 

secondary.

*55

Enter 1

Enter 1

Enter 1 (BAT is Primary 

Communicator)

Setting to 1 gives signal 

priority to GSM (BAT).

*65

Enter 1

Enter 1

Enter 1

Report Code for 

Openings.

*66

Enter 1, 1

Enter 1, 1

Enter 1, 1

Report Code for Arming 

in Away and Stay.

*193

Enter 1, 0

Enter 1, 0

Enter 1, 0

1 turns on/off keypad 

address. 0 sets sound to 

beep.

Содержание BAT WIFI

Страница 1: ...alula net BAT WIFI SKU IPD BAT WIFI Wi Fi Internet Alarm Communicator PRODUCT MANUAL...

Страница 2: ...1 Product Manual BAT WIFI...

Страница 3: ...t Number Location 2 Enter 13 for Contact ID Programming for TELCO use on Vista Section Universal WiFi BAT as Sole Communicator 41 Enter Phone Number 43 Enter Account Number 193 Enter 1 0 Enable to tur...

Страница 4: ...Quick Reference 2 Getting Started 3 Pre Installation 3 Installation Guide 3 DSC Panel Wiring and Programming 6 DSC PC Link Connection 7 DSC Programming Charts 8 Honeywell Vista Panel Wiring and Progr...

Страница 5: ...art Guide An easy to use QuickStart Guide has been designed to make the BAT WiFi easily join the customer s WiFi Network Connecting to a Wireless Network AP Configuration The BAT WIFI has an AP Config...

Страница 6: ...a WiFi router Reset the Wireless Network AP Configuration Tool Locate the button labeled SW1 on the top left of the board When this button is pressed 3 times in a row it causes the device to perform...

Страница 7: ...nable 193 with 1 0 to turn on Address 20 GE Panels Automatically enroll to Keypad Slot Expansion 240 once you enter and exit programming Troubleshooting Diagnostic Information Under normal operation t...

Страница 8: ...keypad functionality works through www alarmdealer com www setup alarmdealer com or the Alula mobile app Ensure that alarm signals reach your central station Wiring Programming for Popular Panels The...

Страница 9: ...8 DSC Keybus Tip Ring Wiring DSC Panel Wiring and Programming...

Страница 10: ...9 DSC PC Link connection This allows for remote downloader functionality with Alula s Universal Downloader uDownloader software DSC PC Link Wiring...

Страница 11: ...n dialer capture mode Section BAT as Sole Communicator BAT as Fail over w Add l Communication Device BAT as Dual Reporting w Add l Communication Device Code Summarization 015 Disable Option 7 If GSM D...

Страница 12: ...on 2 and alternate communications option 5 375 Enable Option 1 Enable Option 1 5 Enable Option 1 2 5 Options to turn on off maintenance for telephone 1 option 1 telephone 2 option 2 and alternate comm...

Страница 13: ...12 Vista Keybus Tip Ring Wiring Vista Panel Wiring and Programming...

Страница 14: ...nother Communication Device for Fail over For Dual Reporting Code Summarization 29 Enter 1 Enter 1 Enter 1 This enables GSM The BAT Emulates a GSM 42 N A Enter Central Station Receiver Number Enter Ce...

Страница 15: ...eral Concept Programming on GE NetworX Section BAT as Sole Communicator Code Summarization Device 0 Location 0 Enter the Phone Number Device 0 Location 1 Enter Account Number Device 0 Location 2 Enter...

Страница 16: ...ric Alarm Panel Programming Program the panel Phone Number into the panel Program the Customers Account Number into the panel Program Reporting codes into the panel Program panel to transmit in Contac...

Страница 17: ...ded A programmable output on the alarm panel will be used to signal to the BAT Y Tx terminal that the panel has entered Arm Disarmed State The Z1 output on the BAT WIFI will be used as a keyswitch con...

Страница 18: ...panel installation manual for details on your specific installation Ademco Typical 56 program zone as type 77 80 Menu LED Outs Program 17 and 18 zone type 78 and 79 DSC PowerSeries Typical Section 001...

Страница 19: ...5PCN 2 6 Vista 15PSIA 4 0 Vista 20P 2 6 Vista 20PCN 2 6 Vista 20PI 5 Vista 20PS 2 6 Vista 20PSIA 4 0 Vista 21IP 1 0 Vista 21IPSIA 1 0 Vista 32FB 1 0 First Alert FA130 2 6 First Alert FA148 2 6 First A...

Страница 20: ...ve should function properly as long as it transmits Contact ID through Tip Ring If the panel has the ability to use a Dedicated Open Zone that acts as a Keyswitch you can Arm Disarm from the Website o...

Страница 21: ...xternally provided 12v DC Typical Current 130 mA Max Current 185mA Environmental Temperature Range 30 to 70 C 22 to 158 F Humidity 0 to 95 non condensing Physical Height 7 05 inches Width 4 45 inches...

Страница 22: ...21...

Страница 23: ...la 1402 Heggen St Hudson WI 54016 888 88 ALULA All product and company names are trademarks or registered trademarks of their respective holders Use of them does not imply any affiliation with or endo...

Отзывы: