Generic Keyswitch Programming
Examples for Ademco, Digital Security Controls, and GE NetworX for keyswitch and panel state program output
operations, as well as Keyswitch state programming are given below.
Most alarm panel manufacturers will have the capability to configure a zone as a keyswitch and generally have
at least one on-board programmable output that can be configured to activate on a number of different control
state conditions. Reference the alarm panel installation manual for details on your specific installation.
Ademco (Typical)
• 56 program zone as type 77
• 80 Menu LED Outs
• Program 17 and 18 zone type 78 and 79
DSC PowerSeries (Typical)
• Section 001 - Zone must be programmed as a 22
• Section 009 - 05
DSC Alexor (Typical)
Wiring:
• Terminal 5 -> I/01
• Terminal 15 -> I/02
• 6.2k ohms resistor from Terminal 3 -> Terminal 5
Programming:
• Section 009 - '05'/'22'
• Section 013 - Enable 2 & Disable 1
• Section 134 - Enable 14 (Press 9, then 6)
• Section 206 - Enable Option 2
• Section 501 - Enable 3
GE NetworX (Typical)
• Device ‘0’ Location 25, press * until you reach desired zone
• Program zone as '11'
• LED Status Device ‘0’
• Location 47 Segment 1: 21
• Location 47 Segment 2: 0