Overview:

Trove2KH2 accommodates various combinations of Kantech boards with or without Altronix power supplies and accessories for access systems. 

Specifications:

• 16 Gauge grey backplane and enclosure with ample knockouts for convenient access.

Trove2KH2

Trove2 enclosure with TKH2 Altronix/Kantech backplane.

• Includes: tamper switch, cam lock, and mounting hardware.
  Enclosure Dimensions (H x W x D): 27.25” x 21.75” x 6.5” (692.15mm x 552.5mm x 165.1mm).

TKH2

Altronix/Kantech backplane only

• Includes mounting hardware.
  Dimensions (H x W x D): 25.375” x 19.375” x 0.3125” (644.5mm x 482.6mm x 7.9mm).

TKH2 accommodates a combination of the following:

Altronix Modules:

• One (1) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB, or eFlow104NB.
•  One (1) T1618300. 
• One (1) PDS8(CB), VR6, ACM8(CB), MOM5, PD4UL(CB), PD8UL(CB), or ACM4(CB)..

Kantech Boards:

• Four (4) KT-MOD-IN16 or KT-MOD-OUT16, or four (4) KT300, or three (3) KT400, or any combination of above.

Agency Listings:

• UL 294 - 6th edition: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II*.
  * Stand-by Power Level I if no battery is supplied.
• This Class B digital apparatus complies with Canadian ICES-003. 
  Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada.
• CE European Conformity. 

Installation Instructions for Trove2:

1.  Remove backplane from enclosure prior to mounting (do not discard hardware).
2. 

Trove2KH2 

(Pg. 4)

Mark and predrill holes on the wall to line up with the top three keyholes in the enclosure. Install three upper 

 

fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws; 

 

level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. 

 

Place the enclosure’s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws.

3.  Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) 
 

in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of 

 

the enclosure approximately 2” from the right side 

(Fig. 1, pg. 2)

 

Connect tamper switch wiring to the Access Control Panel input or the appropriate 

 

UL Listed reporting device. To activate alarm signal open the door of the enclosure.

4.  Mount Altronix/Kantech modules to TKH2 backplane, refer to

 page 3.

Fig. 1

Tamper Switch

(provided)

To Access Control Panel or
UL Listed Reporting Device

Edge of

Enclosure

Enclosure

Содержание TROVE Trove2KH2

Страница 1: ...alling Company _________________________ Service Rep Name __________________________________________ Address _________________________________________________________ Phone _________________________ A...

Страница 2: ...s complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada CE European Conformity Installation Instructions for Trove2 1 Remove backplane from encl...

Страница 3: ...p 2 e Place second metal washer on the bolt Tighten assembly with the nut Fig 2b pg 4 Step 2 f T1618300 s primary leads are black and white Connect AC power 115VAC 50 60Hz to them g Measure output vol...

Страница 4: ...ub Assembly Altronix T1618300 Transformer Metal Spacer Placement Altronix Sub Assembly Step 1a Kantech Spacer Kantech Board Back of TKH2 Step 1b Step 1 Bolt Concave Metal Plate Rubber Washers TKH2 T16...

Страница 5: ...Trove Kantech Installation Guide 5 Notes...

Страница 6: ...LINQ2 Features UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current A...

Страница 7: ...m 19 375 492 1mm 12 625 320 7mm 8 5 215 9mm 16 25 412 8mm 1 0 25 4mm 1 0 25 4mm 9 2 233 7mm 9 2 233 7mm 7 5 190 5mm 7 5 190 5mm 25 375 644 6mm 0 45 11 4mm 0 45 11 4mm 0 156 3 96mm TKH2 Dimensions H x...

Страница 8: ...0 546 1mm 5 25 133 35mm 5 25 133 35mm 6 25 158 8mm 1 25 31 8mm 0 85 21 6mm 0 5625 14 3mm 2 415 61 3mm 0 685 17 4mm 1 77 45mm 0 885 22 5mm 1 125 28 3mm Knockouts 2 00 50 8mm 2 00 50 8mm Trove2KH2 Enclo...

Отзывы: