Note: For independent operation of Output 1 and 2, connect NO
dry contact between IN1 and GND and/or IN2 and GND.
For sequential operation of OUT1 and OUT2 install a jumper
between IN1 and IN2 and a jumper between both GND terminals.
Battery + 24VDC -
Output 1
24V Aux + Output -
20VDC-26.4VDC @ 0.75A
12V Aux + Output -
12VDC @ 0.75A in alarm,
0.5A in stand-by
OUT1 and OUT2
Relock delay adjustment. Used to hold OUT1 or OUT2 energized
after a momentary closure across IN1 or IN2. Set for 0 seconds
for output to follow input. Turn clockwise to increase time.
AC Supervision
Output 2
Delayed 1 - This relay will
activate after 0.5 sec. or 1 sec.
FACP
GND
GND
– OUT1
+
+ BA
T
–
– OUT2
+
IN1
GND
IN2
L
G
N
25A
32V
25A
6.3A
6.3A
250
V
AC
OUT1
TIME
R
Manual Test
OUT2
TIME
R
ON
Option 1 - Option 2
24-5V Hold Voltage
Follow-up Delay 0.5-1 sec.
Fire Alarm Interface
1
2
3
4
AC Power LED
MIN
MAX
INP1
INP2
FAI
BAT
AC
Fire Alarm Interface
Connect these terminals to a normally closed dry contact
that opens upon fire alarm activation.
Input #1
Connect normally open dry contacts from key switch,
timer, remote release or any maintained/momentary
switch. Output #1 energizes while input is closed.
Input #2
Connect normally open dry contacts from key switch,
timer, remote release or any maintained/momentary
switch. Output #2 energizes while input is closed.
Follower 1 - This relay will activate
immediately when OUTPUT 1 is energized.
Delayed 2 - This relay will
activate after 0.5 sec. or 1 sec.
Follower 2 - This relay will activate
immediately when OUTPUT 2 is energized.
C NO C NO
C NC +12VDC– +24VDC–
Delayed 1 Follower 1
C NO C NO
C NO C NO
Delayed 2 Follower 2
C NO C NO
FAULT
C NC
Fig. 2
Wiring Distance Table:
A maximum 0.25 ohm resistance of connecting wires is acceptable, see chart below for wire gauge and distances.
Wire Gauge
Distance
14 AWG Stranded
40 ft.
12 AWG Stranded
60 ft.
10 AWG Stranded
100 ft.
- 6 -
StrikeIt1
Available from A1 Security Cameras
www.a1securitycameras.com email: [email protected]