Altronix Maximal3F Скачать руководство пользователя страница 9

 

Maximal3F/Maximal5F/Maximal7F Access Power Controllers (Fused) 

- 9 -

Access Power Controller Typical Application Diagram 

(for each ACM8): 

NC

NO

C

Normally Open (N.O.)

Door Releasing

Device

Access Control Panel

Output

Relay

Mag.

Lock

MAG.

LOCK

Electric

Strike

Electromagnetic

Door Holders

AC or DC

Power

Supply

(optional)

AC or DC

Power

Supply

(req'd.)

FACP

(Fire Alarm

Control

Panel)

UL Listed

Power Supply

For this application

corresponding

fuse F8 must be

removed.

Keypad

NC  C  NO COM
  OUTPUT 1

LED1

F1

NC  C  NO COM
  OUTPUT 2

IN  GND

1

IN  GND

2

IN  GND

3

IN  GND

4

IN  GND

5

IN  GND

6

IN  GND

7

MAIN

IN  GND

8

LED2

LED3

LED4

LED5

LED6

LED7

LED8

J2

TRG

FACP

NC  C  NO COM
  OUTPUT 3

NC  C  NO COM
  OUTPUT 4

NC  C  NO COM
  OUTPUT 5

NC  C  NO COM
  OUTPUT 6

NO    C     NC

+ INP 

---  

  T    +  

RET  

-

NC  C  NO COM
  OUTPUT 7

NC  C  NO COM
  OUTPUT 8

--- 

    

+

Power

--- 

     

+

Control

F2

F3

F6

F7

F8

F4

F5

J1

J3

TRG

FACP                   INTERFACE

10A 250V

FACP Dry

Form "C" Output 

NO    C     NC

FACP

Intact = Dry Input

Cut = Wet Input

1     2     3     4

O N

1     2     3     4

O N

Enabled

Disabled

FACP Interface

SW1-SW8

ON

1

ON

1

J2

--- 

     

+

Control

J1

Intact = One P/S Input

Cut = Dual P/S Input

NC  C  NO COM
  OUTPUT 8

J3

Intact = DC Input

Cut = AC Input

FACP

Fig. 2

Fig. 2b

Fig. 2c

Fig. 2d

Fig. 2a

Power Supply Board Output Voltage Settings:

--- 

 DC  

+

OFF - 24V
ON - 12V

ON

ON

OFF - 24V

ON - 12V

Fig. 1

Fig. 1a

Содержание Maximal3F

Страница 1: ...Sixteen 16 fuse protected non power limited outputs Maximal7F 24VDC 9 2A Sixteen 16 fuse protected non power limited outputs Rev MSFF052419 More than just power TM Installing Company ________________...

Страница 2: ...upply Board LED Diagnostics pg 7 Access Power Controller LED Diagnostics pg 7 Power Supply Board Terminal Identification pg 7 Access Power Controller Terminal Identification pg 8 Power Supply Board St...

Страница 3: ...e V 12VDC Output Range V 24VDC Output Range V Maximal3F 3 5A 5A 250V 10A 32V 10 0 13 2 20 19 26 4 10 03 13 2 20 19 26 4 12VDC 4 6A or 24VDC 5 2A 16 2 5 10A 250V 3 5A 250V Maximal5F 3 5A 5A 250V 15A 32...

Страница 4: ...L eFlow Power Supply Charger provides common power for ACM8 board factory wiring and all connected access control devices field wiring ACM8 board main fuses are rated 10A Output fuses are rated 3 5A e...

Страница 5: ...user serviceable parts inside Refer installation and servicing to qualified service personnel 3 Select desired DC output voltage by setting SW1 to the appropriate position on the Maximal3F power suppl...

Страница 6: ...AWG for AC Fail Low No Battery reporting 12 To delay AC reporting for 2 hrs set DIP switch AC Delay to OFF position Fig 3 pg 10 To delay AC reporting for 1 min set DIP switch AC Delay to ON position...

Страница 7: ...G DC Factory connected to ACM8 board Trigger EOL Supervised Fire Alarm Interface trigger input from a short or FACP Trigger inputs can be normally open normally closed from an FACP output circuit Clas...

Страница 8: ...9 26 4VDC 5 2A Maximal5F 10 03 13 2VDC 8 6A Maximal7F 20 17 26 4VDC 9 2A Fail Safe NC positive COM Negative Fail Secure NO positive COM Negative Auxiliary output C positive COM Negative When using AC...

Страница 9: ...IN GND 2 IN GND 3 IN GND 4 IN GND 5 IN GND 6 IN GND 7 MAIN IN GND 8 LED2 LED3 LED4 LED5 LED6 LED7 LED8 J2 TRG FACP NC C NO COM OUTPUT 3 NC C NO COM OUTPUT 4 NC C NO COM OUTPUT 5 NC C NO COM OUTPUT 6...

Страница 10: ...l ON Power Supply Board CAUTION When power supply board is set for 12VDC use only one 1 12VDC stand by battery Connect red battery lead to the terminal marked BAT and to the positive terminal of the b...

Страница 11: ...connections must be made employing suitable gauge CM or FPL jacketed wire or equivalent substitute Optional UL Listed battery enclosure must be mounted adjacent to the power supply via Class 1 wiring...

Страница 12: ...TRG J3 NO C NC FACP INTERFACE JUMPER N C DRY TRIGGER INPUT TRG J3 NO C NC FACP INTERFACE N C TRIGGER INPUT N C RESET SWITCH JUMPER TRG J3 N O TRIGGER INPUT TRG J3 NO C NC FACP INTERFACE N C RESET SWI...

Страница 13: ...Maximal3F Maximal5F Maximal7F Access Power Controllers Fused 13 Notes...

Страница 14: ...14 Maximal3F Maximal5F Maximal7F Access Power Controllers Fused Notes...

Страница 15: ...50 8mm 2 50 8mm 6 25 158 75mm 6 25 158 75mm 4 101 6mm 4 101 6mm 2 50 8mm 4 101 6mm 8 9 226 06mm 8 4 213 36mm 7 177 8mm 7 177 8mm 7 177 8mm 8 4 213 36mm 8 5 215 9mm 8 5 215 9mm 7 5 190 5mm 10 254mm 1 5...

Страница 16: ...ada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery status service input trigger state...

Отзывы: