Altronix Maximal3F Скачать руководство пользователя страница 10

 

- 10 - 

Maximal3F/Maximal5F/Maximal7F Access Power Controllers (Fused)

Fig. 3 

Maximal3F, Maximal5F, and Maximal7F.

L

G

N

NC  C  NO 

NC  C  NO

BAT FAIL

AC FAIL

--- 

 DC  

+

AC

AC1

DC

--- 

BA

+

+ AUX –

enable
disable

1 min.
2 hr.

AC DELAY   SHUTDOWN

TRIGGER EOL
SUPERVISED

NO          GND

RESET

OFF   

--- 

  24
V

ON   

--- 

  12
V

O

N

5A 250V

Tamper Switch

Wire 
Strap
(from
Enclosure
to Door)

+  BAT   --- 

 

Optional Rechargeable

Stand-by Battery for

UL294 Applications.

Note: 12V batteries

required for

Canadian installations.

CAUTION: When power supply board is set for

12VDC use only one (1) 12VDC stand-by battery.
Keep power-limited wiring separate from non

power-limited. Use minimum 0.25" spacing. 
12AH Rechargeable batteries are the largest

batteries that can fit in this enclosure.  A UL

listed external battery enclosure must be

used if using the 40AH or 65AH batteries.

Optional Rechargeable

Stand-by Battery

for UL294 Applications

Note: 12V batteries required

for ULC-S319 installations.

Optional Rechargeable

Stand-by Battery

for UL294 Applications

Note: 12V batteries required

for ULC-S319 installations.

Earth Ground

Line

Neutral

ON

Power Supply Board

CAUTION: When power supply board is set for 12VDC

use only one (1) 12VDC stand-by battery.

Connect red battery lead to
the terminal marked [+ BAT]
and to the [positive (+)]
terminal of the battery. 
Connect black battery lead to
terminal marked [BAT –]
and to the [negative (–)]
terminal of the battery.

Input

120VAC 

60 Hz

NC 

NO 

CO

M

 

OUTPUT 

1

LED1

F1

NC 

NO 

COM

 

OUTPUT 

2

IN  GND

1

IN  GND

2

IN  GND

3

IN  GND

4

IN  GND

5

IN  GND

6

IN  GND

7

MAIN

IN  GND

8

LED2

LED3

LED4

LED

5

LED6

LED

7

LED8

J2

TR

G

NC 

NO 

COM

 

OUTPUT 

3

NC 

NO 

COM

 

OUTPUT 

4

NC 

NO 

COM

 

OUTPUT 

5

NC 

NO 

COM

 

OUTPUT 

6

NO    C     NC

+ INP ---

     T    +  RET  

-

NC 

NO 

COM

 

OUTPUT 

7

NC 

NO 

COM

 

OUTPUT 

8

- --     

+

Power

- --      

+

Control

F2

F3

F6

F7

F8

F4

F5

J1

J3

FACP                   INTERF

ACE

10A 250V

1  2  3  

4

ON

1  2  3  

4

ON

NC 

NO 

CO

M

 

OUTPUT 

1

LED1

F1

NC 

NO 

COM

 

OUTPUT 

2

IN  GND

1

IN  GND

2

IN  GND

3

IN  GND

4

IN  GND

5

IN  GND

6

IN  GND

7

MAIN

IN  GND

8

LED

2

LED

3

LED

4

LED

5

LED

6

LED

7

LED

8

J2

TR

G

NC 

NO 

COM

 

OUTPUT 

3

NC 

NO 

COM

 

OUTPUT 

4

NC 

NO 

COM

 

OUTPUT 

5

NC 

NO 

COM

 

OUTPUT 

6

NO    C     NC

+ INP ---

     T    +  RET  

-

NC 

NO 

COM

 

OUTPUT 

7

NC 

NO 

COM

 

OUTPUT 

8

- --     

+

Power

- --      

+

Control

F2

F3

F6

F7

F8

F4

F5

J1

J3

FACP                   INTERF

ACE

10A 250V

1  2  3  

4

ON

1  2  3  

4

ON

Fig. 3b

Fig. 3a

Tamper Switch

(provided)

To Access Control Panel or

UL Listed Reporting Device

Edge of

Enclosure

Enclosure

Содержание Maximal3F

Страница 1: ...Sixteen 16 fuse protected non power limited outputs Maximal7F 24VDC 9 2A Sixteen 16 fuse protected non power limited outputs Rev MSFF052419 More than just power TM Installing Company ________________...

Страница 2: ...upply Board LED Diagnostics pg 7 Access Power Controller LED Diagnostics pg 7 Power Supply Board Terminal Identification pg 7 Access Power Controller Terminal Identification pg 8 Power Supply Board St...

Страница 3: ...e V 12VDC Output Range V 24VDC Output Range V Maximal3F 3 5A 5A 250V 10A 32V 10 0 13 2 20 19 26 4 10 03 13 2 20 19 26 4 12VDC 4 6A or 24VDC 5 2A 16 2 5 10A 250V 3 5A 250V Maximal5F 3 5A 5A 250V 15A 32...

Страница 4: ...L eFlow Power Supply Charger provides common power for ACM8 board factory wiring and all connected access control devices field wiring ACM8 board main fuses are rated 10A Output fuses are rated 3 5A e...

Страница 5: ...user serviceable parts inside Refer installation and servicing to qualified service personnel 3 Select desired DC output voltage by setting SW1 to the appropriate position on the Maximal3F power suppl...

Страница 6: ...AWG for AC Fail Low No Battery reporting 12 To delay AC reporting for 2 hrs set DIP switch AC Delay to OFF position Fig 3 pg 10 To delay AC reporting for 1 min set DIP switch AC Delay to ON position...

Страница 7: ...G DC Factory connected to ACM8 board Trigger EOL Supervised Fire Alarm Interface trigger input from a short or FACP Trigger inputs can be normally open normally closed from an FACP output circuit Clas...

Страница 8: ...9 26 4VDC 5 2A Maximal5F 10 03 13 2VDC 8 6A Maximal7F 20 17 26 4VDC 9 2A Fail Safe NC positive COM Negative Fail Secure NO positive COM Negative Auxiliary output C positive COM Negative When using AC...

Страница 9: ...IN GND 2 IN GND 3 IN GND 4 IN GND 5 IN GND 6 IN GND 7 MAIN IN GND 8 LED2 LED3 LED4 LED5 LED6 LED7 LED8 J2 TRG FACP NC C NO COM OUTPUT 3 NC C NO COM OUTPUT 4 NC C NO COM OUTPUT 5 NC C NO COM OUTPUT 6...

Страница 10: ...l ON Power Supply Board CAUTION When power supply board is set for 12VDC use only one 1 12VDC stand by battery Connect red battery lead to the terminal marked BAT and to the positive terminal of the b...

Страница 11: ...connections must be made employing suitable gauge CM or FPL jacketed wire or equivalent substitute Optional UL Listed battery enclosure must be mounted adjacent to the power supply via Class 1 wiring...

Страница 12: ...TRG J3 NO C NC FACP INTERFACE JUMPER N C DRY TRIGGER INPUT TRG J3 NO C NC FACP INTERFACE N C TRIGGER INPUT N C RESET SWITCH JUMPER TRG J3 N O TRIGGER INPUT TRG J3 NO C NC FACP INTERFACE N C RESET SWI...

Страница 13: ...Maximal3F Maximal5F Maximal7F Access Power Controllers Fused 13 Notes...

Страница 14: ...14 Maximal3F Maximal5F Maximal7F Access Power Controllers Fused Notes...

Страница 15: ...50 8mm 2 50 8mm 6 25 158 75mm 6 25 158 75mm 4 101 6mm 4 101 6mm 2 50 8mm 4 101 6mm 8 9 226 06mm 8 4 213 36mm 7 177 8mm 7 177 8mm 7 177 8mm 8 4 213 36mm 8 5 215 9mm 8 5 215 9mm 7 5 190 5mm 10 254mm 1 5...

Страница 16: ...ada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery status service input trigger state...

Отзывы: