Maximal3F/Maximal5F/Maximal7F Access Power Controllers (Fused)

 MaximalF Series Features:

ACM8 Access Power Controller Modules:

•  Sixteen (16) independently trigger controlled outputs. Output options:
  a) Sixteen (16) Fail-Safe filtered power outputs.
  b) Sixteen (16) Fail-Secure filtered power outputs.
  c) Sixteen (16) form “C” relay outputs (rated @ 5A/28VDC or VAC).
  d) Any combination of the above.
•  Sixteen (16) Access Control System trigger inputs. Input trigger options:
  a) Sixteen (16) normally open (NO) dry trigger inputs.
  b) Sixteen (16) open collector inputs.
  c) Any combination of the above.
•  Sixteen (16) unswitched filtered aux. power outputs (outputs are rated @ 2.5A).
•  Red LEDs on ACM8 board indicate individual outputs are triggered (relays energized).
•  Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
  Fire Alarm disconnect input trigger options:
  a) Normally open (NO) or normally closed (NC) dry trigger input.
  b) Polarity reversal input from FACP signaling circuit.
•  Green LED on ACM8 board indicates FACP disconnect is triggered.
•  FACP output relay indicates that FACP input is triggered 
  (form “C” contact rated @ 1A/28VDC not evaluated by UL).
•  eFlow Power Supply/Charger provides common power for ACM8 board (factory wiring) and all connected 
  access control devices (field wiring).
•  ACM8 board main fuses are rated @ 10A. Output fuses are rated @ 3.5A.

eFlow Power Supply/Charger:

•  Input: 120VAC, 60Hz.
•  For output voltage and supply current refer to MaximalF series Configuration Chart, pg. 3.
•  Auxiliary Power-Limited output rated @ 1A (unswitched).
•  Overvoltage protection.
•  Built-in charger for sealed lead acid or gel type batteries.
•  Maximum charge current 1.54A.
•  Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous
  with no interruption.
•  Supervised Fire Alarm disconnect (latching or non-latching) 10K EOL resistor. Operates on a normally open 
  (NO) or normally closed (NC) trigger.
•  AC fail supervision (form “C” contacts).
•  Battery fail & presence supervision (form “C” contacts).
•  Low power shutdown. Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units 
  and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
•  For fuse ratings refer to MaximalF series Configuration Chart, pg. 3.
•  Green AC Power LED indicates 120VAC present.
•  AC input and DC output LED indicators.
•  Short circuit and overload protection.
•  Enclosure accommodates up to four (4) 12VDC/12AH batteries.
Enclosure dimensions (H x W x D): 26” x 19” x 6.25” (660.4mm x 482.6mm x 158.8mm).

Содержание Maximal3F

Страница 1: ...Sixteen 16 fuse protected non power limited outputs Maximal7F 24VDC 9 2A Sixteen 16 fuse protected non power limited outputs Rev MSFF052419 More than just power TM Installing Company ________________...

Страница 2: ...upply Board LED Diagnostics pg 7 Access Power Controller LED Diagnostics pg 7 Power Supply Board Terminal Identification pg 7 Access Power Controller Terminal Identification pg 8 Power Supply Board St...

Страница 3: ...e V 12VDC Output Range V 24VDC Output Range V Maximal3F 3 5A 5A 250V 10A 32V 10 0 13 2 20 19 26 4 10 03 13 2 20 19 26 4 12VDC 4 6A or 24VDC 5 2A 16 2 5 10A 250V 3 5A 250V Maximal5F 3 5A 5A 250V 15A 32...

Страница 4: ...L eFlow Power Supply Charger provides common power for ACM8 board factory wiring and all connected access control devices field wiring ACM8 board main fuses are rated 10A Output fuses are rated 3 5A e...

Страница 5: ...user serviceable parts inside Refer installation and servicing to qualified service personnel 3 Select desired DC output voltage by setting SW1 to the appropriate position on the Maximal3F power suppl...

Страница 6: ...AWG for AC Fail Low No Battery reporting 12 To delay AC reporting for 2 hrs set DIP switch AC Delay to OFF position Fig 3 pg 10 To delay AC reporting for 1 min set DIP switch AC Delay to ON position...

Страница 7: ...G DC Factory connected to ACM8 board Trigger EOL Supervised Fire Alarm Interface trigger input from a short or FACP Trigger inputs can be normally open normally closed from an FACP output circuit Clas...

Страница 8: ...9 26 4VDC 5 2A Maximal5F 10 03 13 2VDC 8 6A Maximal7F 20 17 26 4VDC 9 2A Fail Safe NC positive COM Negative Fail Secure NO positive COM Negative Auxiliary output C positive COM Negative When using AC...

Страница 9: ...IN GND 2 IN GND 3 IN GND 4 IN GND 5 IN GND 6 IN GND 7 MAIN IN GND 8 LED2 LED3 LED4 LED5 LED6 LED7 LED8 J2 TRG FACP NC C NO COM OUTPUT 3 NC C NO COM OUTPUT 4 NC C NO COM OUTPUT 5 NC C NO COM OUTPUT 6...

Страница 10: ...l ON Power Supply Board CAUTION When power supply board is set for 12VDC use only one 1 12VDC stand by battery Connect red battery lead to the terminal marked BAT and to the positive terminal of the b...

Страница 11: ...connections must be made employing suitable gauge CM or FPL jacketed wire or equivalent substitute Optional UL Listed battery enclosure must be mounted adjacent to the power supply via Class 1 wiring...

Страница 12: ...TRG J3 NO C NC FACP INTERFACE JUMPER N C DRY TRIGGER INPUT TRG J3 NO C NC FACP INTERFACE N C TRIGGER INPUT N C RESET SWITCH JUMPER TRG J3 N O TRIGGER INPUT TRG J3 NO C NC FACP INTERFACE N C RESET SWI...

Страница 13: ...Maximal3F Maximal5F Maximal7F Access Power Controllers Fused 13 Notes...

Страница 14: ...14 Maximal3F Maximal5F Maximal7F Access Power Controllers Fused Notes...

Страница 15: ...50 8mm 2 50 8mm 6 25 158 75mm 6 25 158 75mm 4 101 6mm 4 101 6mm 2 50 8mm 4 101 6mm 8 9 226 06mm 8 4 213 36mm 7 177 8mm 7 177 8mm 7 177 8mm 8 4 213 36mm 8 5 215 9mm 8 5 215 9mm 7 5 190 5mm 10 254mm 1 5...

Страница 16: ...ada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery status service input trigger state...

Отзывы: