Altronix Maximal R Series Скачать руководство пользователя страница 12

 

- 12 - 

Maximal Rack Access Power Controllers (Fused) Installation Guide

Rack Mechanical Drawing and Dimensions

3.25” x 19.125” x 8.5” (82.6mm x 485.8mm x 215.9mm)

---   +

OUT1

---   +

OUT2

---   +

OUT3

---   +

OUT4

---   +

OUT5

---   +

OUT6

---   +

OUT7

---   +

2  1

OUT8

---   +

OUT9

---   +

OUT10

---   +

OUT11

---   +

OUT12

---   +

OUT13

---   +

OUT14

---   +

OUT15

---   +

OUT16

IN1

IN2

IN3

IN5

IN6

IN7

IN8

IN4

GND

GND

GND

RESET

FACP

GND

2  1

IN14

IN15

IN16

GND

RESET

FACP

GND

GND

IN9

IN10

IN11

IN13

IN12

GND

GND

GND

(ON)

Removable Terminal

Block

3-Wire

Line Cord

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

–  +

–  +

–  +

–  +

–  +

–  +

–  +

–  +

2   1

OUT8

IN1

IN2

IN3

IN5

IN6

IN7

IN8

IN4

GND

GND

GND

RESET

FACP

GND

GND

Front

Rear

Top and Bottom

3.125" (79.4mm)

8.5" (215.9mm)

0.75" (19.1mm)

19.125" (485.8mm)

17.625" (447.7mm)

Terminal Legend

Fig. 15

Fig. 15a

Fig. 15b

Fig. 15c

Altronix is not responsible for any typographical errors.

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056

website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty 

IIMaximal Rack Mount Series 

K05U

MEMBER

Содержание Maximal R Series

Страница 1: ...aximal R Series Rack Mount Access Power Controllers fused Models Include Maximal1RH 12VDC 4A or 24VDC 3A Eight 8 fuse protected outputs Maximal3RH 12VDC or 24VDC 6A Eight 8 fuse protected outputs Maxi...

Страница 2: ...Specification Charts pg 5 LED Diagnostics pg 5 Power Supply Board Output Voltage Settings pg 6 Fire Alarm Interface Output Selection and Input Type pg 7 Power Supply Boards Drawings pg 8 FACP Hook Up...

Страница 3: ...2VDC 6A N A 6A 8 2 5A 1 9A 3 5A 250V 24VDC 6A N A Maximal3R 12VDC 6A N A 6A 16 2 5A 1 9A 3 5A 250V 24VDC 6A Maximal33R 12VDC 6A 12VDC 6A 12A 16 2 5A 3 8A 3 5A 250V 24VDC 6A 24VDC 6A 12VDC 6A 24VDC 6A...

Страница 4: ...FACP signaling circuit will trigger the selected outputs Figs 6 11 pg 9 To program the Fire Alarm Interface set dip switches SW1 and SW2 on the ACM8R M board to the appropriate positions Figs 3a and...

Страница 5: ...roper voltage level Output Voltage and Stand by Specification Charts pg 5 Battery Test Under normal load conditions check that the battery is fully charged check specified voltage at the battery termi...

Страница 6: ...2V ON OFF 24V ON 12V ON ON OFF 24V ON 12V The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE withi...

Страница 7: ...TYPE SW3 OUTPUT SELECT ON 4 3 1 2 ON 4 3 1 2 ON 4 3 1 2 ON 4 3 1 2 ON 4 3 1 2 FIRE ALARM INTERFACE OUTPUT SELECT ON 4 3 1 2 ON 4 3 1 2 ON 4 3 1 2 ON 4 3 1 2 INPUT TYPE SW3 SW3 DIP Switch for NO or NC...

Страница 8: ...harging Battery and AC Supervision LOW BAT NC C NO NC C NO AC FAIL ON Power Supply Board Maximal1RH Maximal1R Fig 4 BAT Built in Battery Charging L G N 5A 250V Built in Battery Charging Battery and AC...

Страница 9: ...m FACP Signal Circuit Normally Open NO Reset Switch 1 2 FACP RESET Latching Latching Latching Normally Closed Input from FACP GND IN8 GND Factory Installed Jumper Normally Closed NC Dry Trigger Input...

Страница 10: ...rack enclosure Fig 13a Use three 3 flat head screws B to secure brackets 3 Carefully place faceplate over LEDs and secure using three 3 pan head screws C on top and three 3 pan head screws C on the b...

Страница 11: ...Maximal Rack Access Power Controllers Fused Installation Guide 11 Notes...

Страница 12: ...IN13 IN12 GND GND GND ON Removable Terminal Block 3 Wire Line Cord OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 2 1 OUT8 IN1 IN2 IN3 IN5 IN6 IN7 IN8 IN4 GND GND GND RESET FACP GND GND Front Rear Top and Bottom...

Отзывы: