Altronix eFlow102NA8D Скачать руководство пользователя страница 1

ULC-S319 - Electronic Access Control Systems will be invalidated through the use of any add-on, expansion,
memory or other module manufactured by the manufacturer or other manufacturers.

For a red enclosure add an “R” suffix to the part # e.g. eFlow4NA8DR

Altronix Corp.

140 58th St. Brooklyn, NY

eFlow4NA8D

  -  4A @ 12VDC or 24VDC
  -  Eight (8) PTC Outputs

eFlow6NA8D

  -  6A @ 12VDC or 24VDC
  -  Eight (8) PTC Outputs

eFlow102NA8D

  -  10A @ 12VDC
  -  Eight (8) PTC Outputs

eFlow104NA8D

  -  10A @ 24VDC
  -  Eight (8) PTC Outputs

eFlowNAD8 Series

Access Power Controllers with 
Power Supply/Chargers

Models Include:

Rev. eACMCB052319

More than just power.

TM

Installing Company:  _______________ Service Rep. Name:  __________________________________  

Address:  _____________________________________________  Phone #:  __________________

Installation Guide

Содержание eFlow102NA8D

Страница 1: ...A8D 4A 12VDC or 24VDC Eight 8 PTC Outputs eFlow6NA8D 6A 12VDC or 24VDC Eight 8 PTC Outputs eFlow102NA8D 10A 12VDC Eight 8 PTC Outputs eFlow104NA8D 10A 24VDC Eight 8 PTC Outputs eFlowNAD8 Series Access...

Страница 2: ...mum Supply Current for Main and Aux Outputs A PTC Protected Power Limited Outputs Current per ACM8CB output A ACM8CB Board Input Fuse Rating ACM8CB Board Output PTC Rating DC AUX 12VDC Output Range V...

Страница 3: ...output voltage and supply current refer to eFlowNA8D Series Configuration Chart pg 2 Auxiliary Power Limited output rated 1A unswitched Overvoltage protection Built in charger for sealed lead acid or...

Страница 4: ...ovided Fig 3 pg 8 CAUTION Do not touch exposed metal parts Shut branch circuit power before installing or servicing equipment There are no user serviceable parts inside Refer installation and servicin...

Страница 5: ...leads included Use batteries Casil CL1270 12V 7AH CL12120 12V 12AH CL12400 12V 40AH CL12650 12V 65AH batteries or UL recognized BAZR2 and BAZR8 batteries of an appropriate rating 11 Battery and AC Sup...

Страница 6: ...8 pg 10 or Normally Closed Fig 10 pg 10 latching operation it is necessary to reset the Fire Alarm Disconnect by activating the Normally Closed reset switch Output Voltage Test Under normal load cond...

Страница 7: ...Access Power Controller Terminal Legend Function Description Power 12VDC or 24VDC from power supply charger factory connected These terminals are paralleled to the Control terminals Control These ter...

Страница 8: ...C NO COM OUTPUT 2 IN GND 1 IN GND 2 IN GND 3 IN GND 4 IN GND 5 IN GND 6 IN GND 7 MAIN IN GND 8 LED2 LED3 LED4 LED5 LED6 LED7 LED8 J2 FACP NC C NO COM OUTPUT 3 NC C NO COM OUTPUT 4 NC C NO COM OUTPUT 5...

Страница 9: ...RET NO C NC FACP INTERFACE Power Control F1 F2 F3 F4 F5 F6 F7 F8 MAIN TRG FACP 1 2 3 4 1 2 3 4 O N O N 1 2 3 4 1 2 3 4 O N O N Green Flying Lead Unswitched 120VAC power mains non power limited Optiona...

Страница 10: ...pplications use of conduit is optional All field wiring connections must be made employing suitable gauge CM or FPL jacketed wire or equivalent substitute Optional UL Listed battery enclosure must be...

Страница 11: ...n alarm condition Fig 5 Optional hook up using two 2 isolated power supply inputs Only applicable on eFlow4NA8D not evaluated by UL J2 J1 CUT JUMPERS J1 AND J2 ISOLATED POWER INPUT 12 OR 24 VAC OR VDC...

Страница 12: ...TRG FACP Fig 9 Normally Closed Non Latching FACP trigger input Fig 10 Normally Closed Latching FACP trigger input with reset This output has not been evaluated by UL Fig 8 Normally Open FACP Latching...

Страница 13: ...eFlowNA8D Series Installation Guide 13 Notes...

Страница 14: ...14 eFlowNA8D Series Installation Guide Notes...

Страница 15: ...8mm 1 25 31 8mm 0 79 20 1mm 0 91 23 1mm 0 91 23 1mm 15 5 393 7mm 1 1 27 9mm 1 1 27 9mm 1 1 27 9mm 12 23 310 6mm 2 0 50 8mm 2 0 50 8mm 1 25 31 8mm 1 25 31 8mm Enclosure Dimensions BC400 15 5 x 12 x 4...

Страница 16: ...emote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery status service input trigger state change output...

Отзывы: