Overview:

These Altronix CCTV Power Supplies provide 24VAC/28VAC distributed via sixteen (16) fuse or PTC protected 
outputs for powering CCTV Cameras, heaters and other video accessories.

Sixteen (16) Output ALTV2416UL Reference Chart:

Altronix 

Model Number

Output 

Voltage

Total 

Output 

Current 

(Power)

Number 

of 

Outputs

PTC 

Protected 

Outputs 

(Class 

power 

limited

for 

Dry 

locations). 

(Class 

for 

Wet 

loca

-

tions).

Fuse 

Protected 

Class 

Outputs

Individual 

Output 

Current 

(max. 

per 

output 

not 

to 

exceed 

total 

output 

current).

Fuse 

Rating

s

Main 

Fuse 

Ratings

Primary 

In-line

Fuse 

Rating

s

115VAC 

60Hz

Input 

Current

Agency 

Listing

s

ALTV2416ULX

24VAC

7 amp

16

------

Yes

3.5 amp

3.5 

amp

5A/

250V

3.5A/
250V

1.8

amp

28VAC

6 amp

ALTV2416ULCBX

24VAC

7 amp

16

Yes

------

2.5 amp

------

5A/

250V

3.5A/
250V

1.8

amp

28VAC

6 amp

ALTV2416300UL

24VAC

12.5 amp

16

------

Yes

3.5 amp

3.5 

amp

15A/

32V

------

2.7 

amp

28VAC

10 amp

ALTV2416300ULCB

24VAC

12.5 amp

16

Yes

------

2.5 amp

------

15A/

32V

------

2.7 

amp

28VAC

10 amp

ALTV2416300ULM

24VAC

12.5 amp

16

------

Yes

3.5 amp

3.5 

amp

------

2.7 

amp

28VAC

10 amp

ALTV2416300ULCBM

24VAC

12.5 amp

16

Yes

------

2.5 amp

------

------

------

2.7 

amp

28VAC

10 amp

ALTV2416600UL

24VAC

25 amp

16

------

Yes

3.5 amp

3.5 

amp

15A/

32V

------

5.4 

amp

28VAC

20 amp

ALTV2416600ULCB

24VAC

25 amp

16

Yes

------

2.5 amp

------

15A/

32V

------

5.4 

amp

28VAC

20 amp

Specifications:

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local 
codes and authorities having jurisdiction.  Product is intended for indoor use only. 
1.  Mount unit in desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the
  enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s
  upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the 
  enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two
  upper screws. Install the two lower screws and make sure to tighten all screws 

(Enclosure Dimensions, pgs. 11-12)

.

  Secure enclosure to earth ground. 

• UL Listed for Commercial CCTV Equipment (UL 2044).
  CUL Listed - CSA Standard C22.2 No.1-98, Audio,  
  Video and Similar Equipment.
• Surge suppression.
• AC power LED indicator.
• Power ON/OFF switch 
  (ALTV2416ULX, ALTV2416ULCBX).
• Illuminated power disconnect circuit breaker 
  with manual reset (all other models).
• Unit maintains camera synchronization.

• Ease of installation saves time & eliminates costly labor.
• Spare fuses included (on fuse protected models).

Enclosure Dimensions:

ALTV2416300ULM and ALTV2416300ULCBM: 
8.5”H x 7.5”W x 3.75”D
ALTV2416ULX, ALTV2416ULCBX, ALTV2416300UL, 
ALTV2416300ULCB, ALTV2416600UL and 
ALTV2416600ULCB:
13.5”H x 13”W x 3.25”D

Содержание ALTV2416300UL

Страница 1: ... 12 5 amp 300VA or 28VAC 10 amp 280VA or 28VAC 10 amp 280VA Sixteen 16 Fuse Protected Outputs Sixteen 16 PTC Protected Outputs ALTV2416300ULM ALTV2416300ULCBM 24VAC 12 5 amp 300VA 24VAC 12 5 amp 300VA or 28VAC 10 amp 280VA or 28VAC 10 amp 280VA Sixteen 16 Fuse Protected Outputs Sixteen 16 PTC Protected Outputs ALTV2416600UL ALTV2416600ULCB 24VAC 25 amp 600VA 24VAC 25 amp 600VA or 28VAC 20 amp 560V...

Страница 2: ...Specifications Installation Instructions Wiring methods shall be in accordance with the National Electrical Code NFPA 70 NFPA 72 ANSI and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Mount unit in desired location Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure Install two upper fasteners and screws in ...

Страница 3: ...istribution board marked PD to OFF position for models ALTV2416ULX or ALTV2416ULCBX Figs 1 2 pgs 4 5 Set power disconnect circuit breaker to OFF position for all other models Figs 3a 8a pgs 6 10 8 Connect devices to terminals marked 1P 1N through 8P 8N on PD8 board Figs 1 4 pgs 4 7 Figs 7 8 pgs 9 10 or terminals marked 1P 1N through 16P 16N on PD16W PD16WCB board Figs 5 6 pg 8 carefully observing ...

Страница 4: ...C or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 Class 1 Outputs Fig 1 ALTV2416ULX The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the products enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation po...

Страница 5: ...0 Hz White Lead Black Lead XFMR XFMR non power limited non power limited Black Lead Ground Primary In line Fuse 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC configuration Class 2 Not Wet Class 3 Wet 28VAC configuration Class 1 24VAC config...

Страница 6: ...M M O N P O W E R O U T P U T S P F U S E D P O W E R O U T P U T S 1 2 3 4 5 6 7 8 D1 INPUT N P S R1 LED MAIN FUSE MAIN FUSE Illuminated Power Disconnect Circuit Breaker with manual reset Class 1 Outputs 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 throu...

Страница 7: ... 115VAC input 60 Hz XFMR Ground Connected to Door non power limited non power limited Illuminated Power Disconnect Circuit Breaker with manual reset 24VAC configuration Class 2 Not Wet Class 3 Wet 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24V...

Страница 8: ...s P N XFMR N P S XFMR Input 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 P N Illuminated Power Disconnect Circuit Breaker with manual reset Fig 5 ALTV2416300ULM Transformer underneath power supply board Illuminated Power Disconnect Circuit Breaker with manual reset P N N P S XFMR Input common outputs protected outputs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 N P Fig 6 ALTV2416300ULCBM Fig 5a Fig 6a ...

Страница 9: ...MR Black Lead 115VAC input 60 Hz Ground Connected to Door non power limited non power limited non power limited MAIN FUSE MAIN FUSE Illuminated Power Disconnect Circuit Breaker with manual reset Class 1 Outputs 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2...

Страница 10: ...Hz Ground Connected to Door non power limited non power limited non power limited Illuminated Power Disconnect Circuit Breaker with manual reset 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC configuration Class 2 Not Wet Class 3 Wet XFMR 24...

Страница 11: ...1 1 00 1 75 1 00 1 25 1 25 8 13 1 00 1 00 1 25 8 13 7 25 7 25 1 00 3 85 0 60 1 00 3 85 1 00 0 60 7 25 3 63 1 25 0 90 0 60 3 85 0 60 0 90 8 13 Enclosure Dimensions for ALTV2416300ULM ALTV2416300ULCBM 8 5 H x 7 5 W x 3 75 D ...

Страница 12: ...th Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A II1ALTV2416ULSeries G16L Enclosure Dimensions for ALTV2416ULX ALTV2416ULCBX ALTV2416300UL ALTV2416300ULCB ALTV2416600UL ALTV2416600ULCB 13 5 H x 13 W x 3 5 D ...

Отзывы: