background image

 

- 6 - 

AL400X220 Series

Power Distribution Module(s):

Fig. 2a  -  PD4 Power Distribution Board 

Fig. 2b  -  PD4CB - Power Distribution Board

 

  Fuse Protected Outputs 

 

  PTC Protected Outputs

Fig. 3a  -  PD8 Power Distribution Board 

Fig. 3b  -  PD8CB - Power Distribution Board

 

  Fuse Protected Outputs 

 

  PTC Protected Outputs

LED

F1

F2

F3

F4

1P

1N

2P

2N

3P

3N

4P

4N

DC Output to devices

1P-4P Power Outputs,

1N-4N Common Outputs

From Power Supply

Board

(Factory Installed)

Replace fuses with the same type and rating 3.5A/250V  

N

COMMON   POWER   OUTPUTS

P

FUSED    POWER    OUTPUTS

8

D1

INPUT

R1

LED

DC Output to devices

1P-8P Power Outputs,

1N-8N Common Outputs

From Power Supply

Board

(Factory Installed)

Replace fuses with the same type and rating 3.5A/250V  

LED

F1

F2

F3

F4

1P

1N

2P

2N

3P

3N

4P

4N

DC Output to devices

1P-4P Power Outputs,

1N-4N Common Outputs

From Power Supply

Board

(Factory Installed)

N

COMMON   POWER   OUTPUTS

P

FUSED    POWER    OUTPUTS

8

D1

INPUT

R1

LED

DC Output to devices

1P-8P Power Outputs,

1N-8N Common Outputs

From Power Supply

Board

(Factory Installed)

Содержание AL400X220 Series

Страница 1: ...nclude For a red enclosure add an R suffix to the part e g AL400PD8R220 For a larger enclosure add an X suffix to the part e g AL400XPD8220 Installation Guide AL400X220 Single Output AL400PD4220 Four...

Страница 2: ...D8220 Two 2 12VDC 12AH AL400PD8CB220 PD8CB P 2 5A Two 2 12VDC 7AH AL400XPD8CB220 Two 2 12VDC 12AH AL400XPD16220 Two PD8 16 P 3 5A 12VDC 3A 24VDC Two 2 12VDC 12AH AL400XPD16CB220 Two PD8CB P 2 5A Two 2...

Страница 3: ...DC DC BAT F1 Off 24V On 12V SW1 ON Switch Position 24VDC SW1 OFF 12VDC SW1 ON Battery AC Supervision Circuit J1 AC Delay Power Distribution Module s Ground Lug 220VAC power mains Battery connection CA...

Страница 4: ...hrough 8P 8N Fig 3a 3b pg 6 carefully observing correct polarity 6 For Access Control applications batteries are optional When batteries are not used a loss of AC will result in the loss of output vol...

Страница 5: ...larm panel Relay normally ener gized when AC power is present Contact rating 1A 28VDC AC Fail condition will report approximately within one 1 minute after loss of AC To delay report for 6 hours cut j...

Страница 6: ...stalled Replace fuses with the same type and rating 3 5A 250V N COMMON POWER OUTPUTS P FUSED POWER OUTPUTS 1 2 3 4 5 6 7 8 D1 INPUT R1 LED DC Output to devices 1P 8P Power Outputs 1N 8N Common Outputs...

Страница 7: ...82 6mm 1 40 35 6mm 1 40 35 6mm 1 40 35 6mm 4 85 123 2mm 4 85 123 2mm 3 25 82 6mm 0 75 19 1mm 0 75 19 1mm 11 0 279 4mm 12 5 317 5mm 1 20 30 5mm 1 20 30 5mm 0 9375 23 8mm 0 9375 23 8mm 5 10 129 5mm 1 40...

Страница 8: ...4 5mm 1 375 34 9mm 1 125 28 6mm 1 5 38 1mm 1 5 38 1mm 5 0 127 0mm 5 0 127 0mm 4 5 114 3mm 4 5 114 3mm 1 25 31 8mm 1 25 31 8mm 0 79 20 1mm 0 91 23 1mm 0 91 23 1mm 15 5 393 7mm 1 1 27 9mm 1 1 27 9mm 1 1...

Отзывы: