LED Diagnostics:

PD4UL/PD4ULCB/PD8UL/PD8ULCB - Power Distribution Module

Green

Power Distribution Module Status

ON

Normal operating condition.

OFF

No Power Output.

Terminal Identification:

PD4UL/PD4ULCB/PD8UL/PD8ULCB - Power Distribution Module

Terminal Legend

Function/

PD4UL/PD4ULCB

PD8UL/PD8ULCB

Description

1P to 4P

1P to 8P

Positive DC power outputs.

1N to 4N

1N to 8N

Negative DC power outputs.

LED

F1

F2

F3

F4

1P

1N

2P

2N

3P

3N

4P

4N

Non-Power Limited

DC Output to devices

1P-4P Power Outputs,

1N-4N Common Outputs

()

From Power Supply

Board

(Factory Installed)

Replace fuses with the same type and rating 3.5A, 250V.  

Fig. 2A

Fig. 3A

Power Distribution Module(s):

INPUT

LED

F1

F2

F3

F4

POWER   OUTPUTS

1P

1N

2P

2N

3P

3N

4P

4N

Class 2 Rated Power Limited

DC Output to devices

1P-4P Power Outputs,

1N-4N Common Outputs

From Power Supply

Board

(Factory Installed)

(

)

Fig. 2B

N

COMMON   POWER   OUTPUTS

P

FUSED    POWER    OUTPUTS

1

2

3

4

5

6

7

8

D1

INPUT

R1

LED

From Power Supply

Board

(Factory Installed)

Replace fuses with the same type and rating 3.5A, 250V.  

Non- Power Limited

DC Output to devices

1P-8P Power Outputs,

1N-8N Common Outputs

()

N

COMMON   POWER   OUTPUTS

P

FUSED    POWER    OUTPUTS

1

2

3

4

5

6

7

8

D1

INPUT

R1

LED

From Power Supply

Board

(Factory Installed)

Class 2 Rated Power Limited

DC Output to devices

1P-8P Power Outputs,

1N-8N Common Outputs

(

)

Fig. 3B

Содержание AL1024ULXPD4

Страница 1: ...ingle Output AL1024ULXPD4 AL1024ULXPD4CB Four 4 Fused Outputs Four 4 PTC Outputs AL1024ULXPD8 AL1024ULXPD8CB Eight 8 Fused Outputs Eight 8 PTC Outputs AL1024ULXPD16 AL1024ULXPD16CB Sixteen 16 Fused Ou...

Страница 2: ...type batteries Automatic switch over to stand by battery when AC fails Maximum charge current 3 6 amp Zero voltage drop when switched over to battery backup Supervision AC fail supervision form C cont...

Страница 3: ...should be installed in accordance with article 760 of The National Electrical Code as well as NFPA 72 and all applicable Local Codes 1 Mount the unit in desired location DC BAT FAIL NO C NC NO C NC B...

Страница 4: ...en used in fire alarm burglar alarm or access control applications AC Fail relay must be used to provide a visual indication of AC power on 7 Please insure that the cover is secured with the provided...

Страница 5: ...ace fuses with the same type and rating 3 5A 250V Fig 2A Fig 3A Power Distribution Module s INPUT LED F1 F2 F3 F4 POWER OUTPUTS 1P 1N 2P 2N 3P 3N 4P 4N Class 2 Rated Power Limited DC Output to devices...

Страница 6: ...load conditions the DC output voltage should be checked for proper voltage level Battery Test Under normal load conditions check that the battery is fully charged check specified voltage both at batt...

Страница 7: ...A G Alarm duration Hours 15 Min 2 Hour Alarm ____________ H H Battery capacity required for Alarm E F G ____________ AH I Total calculated battery capacity D H ____________ AH J Battery capacity requ...

Страница 8: ...com e mail info altronix com Lifetime Warranty Made in U S A IIAL1024ULX series L22E MEMBER 8 875 1 1 3 9 97 13 53 6 625 2 25 3 68 4 56 1 22 1 22 3 5 1 13 25 2 1 22 12 15 5 4 5 2 25 3 68 4 56 1 22 1...

Отзывы: