www.altronics.com.au
Redback® Proudly Made In Australia
24
Peripheral Connections
5.1.1 Features
• Multi zone paging.
• Zone lock out facility.
• Recall multiple zones with a single button press.
• Keyboard entry labelling of recall zones.
• LCD for indicating zone selections.
• Pre-announcement chime.
• Emergency override paging to all zones.
5.1.2 DIP Switch Settings
A series of DIP switches which are accessed on the rear of the unit provide a number of
options. Table 5.1A shows the settings available.
DIP switch 1 sets the PA system chime on or off.
DIP switch 2 sets the internal chime on or off.
DIP switch 3 sets the emergency paging on or off
DIP switches 4&5 are not used.
DIP switches 6-8 select the ID number for the console.
Table 5.1a shows the ID settings.
A maximum number of 8 consoles can be connected
to the A 4480 audio switcher.
Table 5.1A shows the ID settings available.
5.1.3 Connecting the paging consoles
Fig 5.1B
Table 5.1A
230VAC
(AC Fuse 1A M205)
Output
Voice Chime Alert
Over
& Evac
Earth Lift 24VDC In DC Fuse
(2A M205)
Lift/Chassis
- +
Optional
Settings
SW4
(Not Used)
1 2 3 4
ZONE PLATES OR PRESET PLATES
USB
Keyboard
INPUTS
SW1
SW2
8
7
6
5
4
3
2
1
Expansion IN Expansion OUT
SW5
ON
OFF
1 Phantom Phantom
Power On Power Off
2
Mic Level Line Level
Switches 3 & 4 Not Used
Vox
Level
Volume
Priority Input
L
R
Vox
Level
Trigger
Paging Consoles / Preset Plates
2
1
1 2 3 4
Input 1 & 2 XLR
Aux Input Sensitivity
DIP Switch Settings
SW1
ON OFF
(1) Input 1 0.3V 0.7V
(2) Input 2 0.3V 0.7V
(3) Input 3 0.3V 0.7V
(4) Input 4 0.3V 0.7V
SW2
ON OFF
(1) Input 5 0.3V 0.7V
(2) Input 6 0.3V 0.7V
(3) Input 7 0.3V 0.7V
(4) Input 8 0.3V 0.7V
ALERT - EVACUATION MODULE
Manufactured in Australia By
Altronic Distributors Pty. Ltd.
www.altronics.com.au
1 2 3 4
L
R
SW3
EVA
C
CO
M
CAN
CHIME
ALER
T
SW
ON OFF
Phantom Power
(1) Input 1
ON OFF
(2) Input 2 ON OFF
(3) Not Used
(4)
Not Used
2
1
3
1 - Shield
2 - Hot
3 - Cold
1 - Shield
2 - Hot
3 - Cold
2
1
3
Dip Switch 3 Settings
Triggers
Levels
OUTPUT
S
8
7
6
5
4
3
2
1
EMERGENCY INPUT
RISK OF ELECTRIC SHOCK
OPEN BY QUALIFIED
PERSONNEL ONLY
!
CAUTION
8
6
4
7
5
3
2
1
SW5
2
1
3
2
1
3
ON
1 2 3 4
ON
1 2 3 4
ON
1 2 3 4
ON
1 2 3 4
ON
1 2 3 4
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
CONSOLE 1
CONSOLE 2
Max 300m
Max 300m
6
7
8
DIP Switches 6-8
Set the Paging
Off Off Off
Console ID
ID
On Off Off
On On Off
Off On Off
Off Off On
On Off On
On On On
Off On On
7
8
1
2
3
4
5
6