www.altronics.com.au
Redback® Proudly Made In Australia
9
230VAC
(AC Fuse 1A M205)
Output
Voice Chime Alert
Over
& Evac
Earth Lift 24VDC In DC Fuse
(2A M205)
Lift/Chassis
- +
Optional
Settings
SW4
(Not Used)
1 2 3 4
ZONE PLATES OR PRESET PLATES
USB
Keyboard
INPUTS
SW1
SW2
8
7
6
5
4
3
2
1
Expansion IN Expansion OUT
SW5
ON
OFF
1 Phantom Phantom
Power On Power Off
2
Mic Level Line Level
Switches 3 & 4 Not Used
Vox
Level
Volume
Priority Input
L
R
Vox
Level
Trigger
Paging Consoles / Preset Plates
2
1
1 2 3 4
Input 1 & 2 XLR
Aux Input Sensitivity
DIP Switch Settings
SW1
ON OFF
(1) Input 1 0.3V 0.7V
(2) Input 2 0.3V 0.7V
(3) Input 3 0.3V 0.7V
(4) Input 4 0.3V 0.7V
SW2
ON OFF
(1) Input 5 0.3V 0.7V
(2) Input 6 0.3V 0.7V
(3) Input 7 0.3V 0.7V
(4) Input 8 0.3V 0.7V
ALERT - EVACUATION MODULE
Manufactured in Australia By
Altronic Distributors Pty. Ltd.
www.altronics.com.au
1 2 3 4
L
R
SW3
EVA
C
CO
M
CAN
CHIME
ALER
T
SW
ON OFF
Phantom Power
(1) Input 1
ON OFF
(2) Input 2 ON OFF
(3) Not Used
(4)
Not Used
2
1
3
1 - Shield
2 - Hot
3 - Cold
1 - Shield
2 - Hot
3 - Cold
2
1
3
Dip Switch 3 Settings
Triggers
Levels
OUTPUT
S
8
7
6
5
4
3
2
1
EMERGENCY INPUT
RISK OF ELECTRIC SHOCK
OPEN BY QUALIFIED
PERSONNEL ONLY
!
CAUTION
8
6
4
7
5
3
2
1
SW5
2
1
3
2
1
3
ON
1 2 3 4
ON
1 2 3 4
ON
1 2 3 4
ON
1 2 3 4
ON
1 2 3 4
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
1
5
8
9
6
7
2 3
4
10 11
12
18
13
14
15
16
17
19
23
20
21
22
24
1.5 REAR PANEL CONNECTIONS
Fig 1.5A shows the layout of the A 4480 rear panel.
Fig 1.5A
1
Voice Over Volume
Use
this trimpot adjustment to change the output level of the playback message.
2
Chime Volume
Use this trimpot adjustment to change the output level of the chime volume.
3
Alert and Evacuation Volume
Use this trimpot adjustment to change the output level of the alert and evacuation tone.
4
Alert, Evacuation, chime and cancel contacts
Use these contacts to trigger the chime tones, the alert tone, the evacuation tone and to cancel any
of the tones once triggered. All tones & cancel function are operated by a closing contact to ground.
This could be triggered via building fire indicator board, break glass alarm etc.
Output
Voice Chime Alert
Over
& Evac
ALERT - EVACUATION MODULE
EVA
C
CO
M
CAN
CHIME
ALER
T
Triggers
Levels
Fig 1.5B
Overview
5
Stereo RCA input connectors
Connect these inputs (1-8) to the input audio sources such as a CD player etc. These inputs are converted to
mono internally. Note. Inputs 1 &2 also have a line level XLR input. (Refer to section 7 over)