CPU-XL VariSpark IOM 07-21
All rights reserved © ALTRONIC, LLC 2021
81
Register
Label
Min
Max
Default
REG40169
Cylinder Bar Graph Center
20
235
85
REG40170
Cyl Bar Graph Counts Per Point
1
5
1
REG40171
EAVG Bar Graph Spread
1
255
30
REG40172
THROUGH
REG40191
RESERVED
0
65535
0
REG40192
Coil 001-016
0
65535
65535
REG40193
Coil 017-032
0
65535
65535
REG40194
Coil 033-048
0
65535
255
REG40195
Coil 049-064
0
65535
0
REG40196
Coil 065-080
0
65535
0
REG40197
Coil 081-096
0
65535
0
REG40198
Coil 097-112
0
65535
0
REG40199
Coil 113-128
0
65535
16384
REG40200
THROUGH
REG40249
RESERVED
0
65535
0
REG40250
RTC Year
2007
2099
2012
REG40251
RTC Date msb=month,lsb=day
101
1231
101
REG40252
RTC Time msb=hour,lsb=minutes
0
2359
1200
REG40253
RTC Seconds
0
59
0
REG40254
Key Command Data
0
65535
0
REG40255
Key Commands
0
65535
0
REG40256
RESERVED
0
65535
0
32.1 Modbus Exception Codes
The CPU-XL Modbus implementation will return these Modbus error codes to requests
made that are incorrect based on the error encountered.
STATUS CODE
MEANING
DESCRIPTION
01
ILLEGAL FUNCTION
The function code received in the query is not an allowable action for the slave.
02
ILLEGAL DATA ADDRESS
The data address received in the query is not an allowable address for the slave.
This may also occur if coils or discrete inputs are not read on an octal boundary
(eg, 1, 9, 17, etc) and / or not in quantities that are a multiple of 8.
03
ILLEGAL DATA VALUE
A value contained in the query data field is not an allowable value for the slave.
This may also be the result when the number of bytes sent in a request does not
match the expected number of bytes for the request (eg, too few bytes written in
a function 16 request).
04
SLAVE DEVICE FAILURE
An unrecoverable error occurred while the slave was attempting to perform the
requested action. This may occur when a request must be relayed directly to the
ignition module and the ignition module rejects it).
06
SLAVE DEVICE BUSY
The slave is engaged in processing a long–duration program command. The mas-
ter should retransmit the message later when the slave is free. This may occur if
the display module has lost communication with the ignition module.
09
OVERFLOW
The master has sent an otherwise valid request, but the request length exceeded
the size of the internal request buffer. The maximum request length supported is
270 bytes.
Содержание VariSpark CPU-XL
Страница 86: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 86 FIGURE 5 PICKUP MOUNTING DETAIL...
Страница 87: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 87 FIGURE 6 FLYWHEEL HOLE DRILLING...
Страница 88: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 88 FIGURE 7 MAGNET ASSEMBLY...
Страница 89: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 89 FIGURE 8 MAGNET ASSEMBLY...
Страница 90: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 90 FIGURE 9 MAGNET ASSEMBLY...
Страница 91: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 91 FIGURE 10 HALL EFFECT PICKUP...
Страница 93: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 93 FIGURE 12 SHIELDED HARNESS 293030...
Страница 94: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 94 FIGURE 13 SHIELDED HARNESS 793101...
Страница 95: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 95 FIGURE 14 SHIELDED HARNESS 793102...
Страница 96: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 96 FIGURE 15 TIMING CURVE 4 20mA...