16
Possible faults
Before each fault clearance
Switch off device
Wait for standstill of the saw blade
Pull out power plug
After each fault clearance, put into operation and recheck all security installations.
Fault
Possible cause
Removal
Machine fails to start
after switching on or
switches off during idle
running
Power failure
Extension cable defect
Motor or switch defect
Check safety fuse
Check cable, no longer use defect cable
Have motor or switch checked by an approved elec-
trician or replaced by original spare parts
No crosscut function
Transport locking pin not removed
Locking device for pendulum cover not opened
Pull out transport locking pin (5)
Open locking device (17)
Machine stops while
cutting
Saw blade is dull
Feed is too great
Replace saw blade (16)
Allow motor to cool and proceed working with less
pressure
Burned spots at the cut
areas
Saw blade is not suitable for the work step or
is dull
Replace saw blade
Saw vibrates
Saw blade is warped
Saw blade not properly mounted
Replace saw blade
Mount saw blade properly
Chip outlet is clogged
No exhaust system connected
Exhaust power too weak
Switch off saw, remove chips and connect exhaust
system
Switch off saw, remove chips and increase exhaust
power (air velocity 20 m/sec at chip exhaust neck.
Rotary table moves hard
Chips under rotary table
Remove chips
In case of further faults or inquiries please contact your local dealer.
Technical data
Model / Type
KGS 210 N
Year of constructions
see last page
Motor output P
1
1400 W
Mains voltage
230 V~
Mains frequency
50 Hz
No-load speed
5000 min
–1
Saw blade diameter
210 mm
Saw blade hole
25,4 mm
min. tooth width
2,8 mm
Mitre left/right
0-45 °
Incline angle left
0-45°
Max. cross-section of work piece (height x width)
Straight cuts:
50 x 120 mm
Mitre cuts (rotary table 45°)
50 x 80 mm
Inclined cuts (saw head 45° to the left)
30 x 120 mm
Double mitre cuts (rotary table 45°/saw head 45°)
30 x 80 mm
Exhaust connection
38 mm
Dimensions (length x breadth x height)
260 x 390 x 380 mm
Weight approx.
6,2 kg
Commercial chip exhaust system or industrial vacuum cleaners can be used for exhaustion.
Technical
modifications
reserved!
Содержание 302563
Страница 26: ...26 II E 2012 19 E DIN EN ISO 3744 DIN EN ISO 11202 ISO 7960 A LWA 106 dB A LpA 93 dB A K 3 dB HSS...
Страница 28: ...28 3 5 40 230 V 30 mA IEC 60 245 H 07 RN F 1 5 mm 25 m 2 5 mm 25 m 2 a 21 21 22 22 40 mm 20 34 34 7 8 0 6 A 18...
Страница 30: ...30 6 20 25 26 5 35 17 1 27 16 28 27 28 26 25 4 mm 33...
Страница 31: ...31 0 3 5 2 5 17 16 20...