MOVING A DISABLED DUMPER
If the dumper becomes disabled, it must be made safe and lifted onto a suitable transport vehicle to be taken to a location where it can
be repaired.
Moving a disabled machine without following the correct procedures will damage parts of the hydraulic system. If possible, the disabled
machine will be repaired where it stands.
JUMP-STARTING THE ENGINE
When the dumper battery is discharged, the engine can be jump-started using a slave battery from another vehicle and jump leads.
ENSURE the slave battery has a nominal voltage of 12v and a capacity at least equal to that of the
discharged battery.
WARNING
•
Before jump-starting the dumper,
ENSURE
all switches are in the off position.
•
The dumper must
NEVER
come into contact with the slave vehicle when connected with jump leads. This is a potential sparking
hazard!
•
ALWAYS
XVHMXPSOHDGVWKDWKDYHVXI¿FLHQWFDSDELOLW\WRFDUU\WKHVWDUWLQJFXUUHQW
1. Connect the jump leads:-
- Connect the red jump lead (Figure 23, Item A) to the positive terminal (+) of the discharged battery (Item C) and then to the
positive terminal (+) of the slave battery (Item D).
- Connect one end of the black jump lead (Item B) to the negative terminal (-) of the slave battery.
- Connect the other end of the black jump lead onto an earth point of the disabled dumper (Item E)
NOTE:-
A suitable earth point would be part of the dumper chassis which is free from paint / dirt or the negative terminal of the
disabled
battery.
2. Carry out the dumper pre-start checks procedure (See page 22)
3. Start the engine on the vehicle with the slave battery. Leave it running for a few minutes.
4. Start the engine on the disabled dumper. If the engine does not start straight away, switch off the iginition and wait a few moments
before trying again.
5. Disconnect the jump leads:-
- Disconnect the black jump lead from the earthed position on the disabled dumper. Then disconnect from the negative terminal (-)
of the slave battery.
- Disconnect the red jump lead from the positive terminal (+) of the dumper battery and then disconnect from the positive
terminal (+) of the slave battery.
12v
12v
A
B
D
C
E
Figure. 23
A. Red Jump Lead (Po)
B. Black Jump Led (Negative -)
C. Disabled Dumper Battery
D. Slave Battery
E. Suitable Earthing Point