background image

MN-36580 (Rev. 2) 01/16 • Quickchillers • 1

D e l I V e r y

This Alto-Shaam appliance has been thoroughly 
tested and inspected to ensure only the highest 
quality unit is provided. Upon receipt, check for any 
possible shipping damage and report it at once to the 
delivering carrier. See Transportation Damage and 
Claims section located in this manual.

This appliance, complete with unattached items 
and accessories, may be delivered in one or more 
packages. Ensure all standard items and options 
have been received with each model as ordered.

Save all the information packed with the appliance. 
Register online at www.alto-shaam.com to ensure 
prompt service in the event of a warranty parts and 
labor claim.  

This manual must be read and understood by all 
people using or installing the equipment model.  
Contact the Alto-Shaam Tech Team Service 
Department if you have any questions concerning 
installation, operation, or maintenance.

1-800-558-8744; [email protected]

u n p a c k I n g

•  Carefully remove the appliance 

from the carton or crate.

 

NotICE:

  

 Do not discard the 
carton and other 
packaging material 
until you have 
inspected the unit 
for hidden damage 
and tested it for 
proper operation.

•  Read all instructions in this manual carefully 

before installing this appliance, using the appliance 
or performing routine maintenance. Following 
procedures other than those indicated in this 
guide to use and clean the appliance is considered 
inappropriate and may cause damage, injury or 
fatal accidents, in addition to invalidating the 
guarantee and relieving Alto-Shaam of all liability.

•  DO NOT DISCARD THIS MANUAL.  

This manual is considered part of the appliance 
and is provided for the owner or manager of the 
business and for training personnel. Additional 
manuals are available from the Alto-Shaam 
Tech Team Service Department.

•  Remove all protective plastic film, packaging 

materials, and accessories from the appliance 
before connecting electrical power. Store any 
accessories in a convenient place for future use.

®

®

W a r n I n g

Appliance and accessories may be 
heavy. To prevent serious injury, 
ALWAYS use a sufficient number 
of trained and experienced workers 
when moving or leveling appliance 
and handling accessories.

enVIronMental conDItIons

• Operational Environmental Conditions

• Unit must acclimate to room temperature in the 

environment it is placed. 24 hours is recommended.

• Ambient temperature range of 50° to 110°F (10° to 43°C).

• Relative humidity of less than 95% non-condensation.

• Atmospheric pressure range of 50KPa to 106KPa.

Always include both model and serial numbers in your correspondence 

regarding the unit.

 Model:   _____________________________________
 

Serial Number:   _____________________________________

  Purchased From:   _____________________________________
 

Date Installed:   ____________  Voltage:   _______________

SERIAL NUMBER IS REQUIRED FOR ALL INQUIRIES 

Delivery

Unpacking

Содержание Quickchiller QC2-100

Страница 1: ...U S A CANADA FAX 262 251 7067 800 329 8744 U S A ONLY www alto shaam com Consult instructions for operation and use MN 36580 Re v 2 01 16 p r i n t e d i n u s a Model QC2 3 QC2 20 QC2 40 QC2 100 QC2...

Страница 2: ...n Operation 18 Touch Screen Menus 18 Chill Using Preset Recipes 19 Chill Modes 20 Professional Mode Chill 21 Professional Mode Hold 22 Downloads 23 Settings 25 Service 27 Error Codes 27 Error Messages...

Страница 3: ...res other than those indicated in this guide to use and clean the appliance is considered inappropriate and may cause damage injury or fatal accidents in addition to invalidating the guarantee and rel...

Страница 4: ...ur staff to avoid the risk of accident or damage to the unit Operators must also receive regular safety instructions Any troubleshooting guides component views and parts lists included in this manual...

Страница 5: ...owly Escaping hot vapors or steam can cause serious injury or death aDDItIonal safety proceDures anD precautIons If your gas appliance is installed under an exhaust hood the hood must be switched ON w...

Страница 6: ...rbroilers or any other equipment producing grease laden air heat producing equipment such as ovens and ranges and steam discharging equipment such as steamer ovens and kettles Do not locate the Quickc...

Страница 7: ...and positive seal around the entire door frame Refrigeration QC2 100R Alto Shaam does not offer recommendations on maximum run sizes Best refrigeration piping practices should always be followed and...

Страница 8: ...ht 17 5 8 447mm Front DRAINAGE QC2 3 QC2 20 QC2 40 Evaporator Pan no installation required QC2 100 One 1 Floor Drain 1 2 12 7mm diameter Drain It is recommended that legs be attached to the unit befor...

Страница 9: ...ver 1 2 Remove screws from hinge 2 3 Remove metal cap 3 4 Insert flat screwdriver into slot and pry out 4 Rotate cam so that deep grove is positioned to the right for left hand hinge or left for right...

Страница 10: ...quarts 28 5 liters full size pans gastronorm 1 1 Three 3 20 x 12 x 2 1 2 530 x 325 x 65mm refrigeration 40 oz R404a Refrigerant One 1 1 2 hp Condensing Unit 2 800 BTU s per hour at 5 F 21 C in the fr...

Страница 11: ...5 liters full size pans gastronorm 1 1 Five 5 20 x 12 x 2 1 2 530 x 325 x 65mm full size sheet pans Nine 9 18 x 26 x 1 refrigeration 40 oz R404a Refrigerant One 1 3 4 hp Condensing Unit freeze mode 4...

Страница 12: ...18 x 26 x 1 refrigeration 80 oz R 404a Refrigerant One 1 1 1 2 hp Condensing Unit freeze mode 5 880 BTU s per hour at 5 F 21 C chill mode 11 400 BTU s per hour at 20 F 7 C INSTALLATION s ite installa...

Страница 13: ...p contact factory carton dimensions l x w x h 57 x 44 x 94 1448mm x 1118mm x 2388mm refrigeration 200 oz R 404a Refrigerant One 1 3 hp Condensing Unit freeze mode 11 300 BTU s per hour at 5 F 21 C chi...

Страница 14: ...um volume maximum 300 quarts 380 liters Maximum Chilling Capacity Approximately 240 lb 109 kg maximum volume maximum 150 quarts 190 liters full size pans gastronorm 1 1 Forty 40 20 x 12 x 2 1 2 530 x...

Страница 15: ...20 20e 20 20g 20 20mw and QC2 100 69 5 8 x 26 7 8 x 42 1 2 1769 x 683 x 1080mm 3 11 16 93mm vertical spacing between shelves 5016480 5017151 ci 60 plate trolley Fits 20 10e 20 10g 20 20mw and QC2 100...

Страница 16: ...No 70 In Canada all electrical connections are to be made in accordance with CSA C22 1 Canadian Electrical Code Part 1 or local codes W arnIng To prevent SERIOUS INJURY DEATH or PROPERTY DAMAGE All e...

Страница 17: ...oth safety and product quality 2 Modified Cook Chill Operations where a significant portion of food is cooked for immediate service and a smaller portion of more labor intensive hot food items are pre...

Страница 18: ...probe or probes inserted into the center of the food The cycle is automatically terminated when the center of the food reaches the probe sensing temperature set by the operator In units with multiple...

Страница 19: ...to serving DOOR If the QC2 40 or QC2 100 door is opened during any running chill or freeze cycle the fans will disengage and a DOOR IS OPEN message will appear on the screen If the door is open for lo...

Страница 20: ...e Defrost Duration Drip Time Factory Presets Screen Calibration Sleep Mode Professional Mode Recipes Home Probe Count Alarm Demo Mode E 10 E 11 P 10 P 20 P 30 C 10 C 11 E 80 E 84 E 83 E 53 E 54 E 66 E...

Страница 21: ...Chill 14 F 38 F 38 F 2 Beef Hard Chill 14 F 38 F 38 F 3 Casserole Hard Chill 14 F 38 F 38 F 4 Chicken Breast Soft Chill 34 F 38 F 38 F 5 Chicken Whole Hard Chill 14 F 38 F 38 F 6 Duck Hard Chill 14 F...

Страница 22: ...the default hold temperature found under the User Settings Use Hold Temp to hold chilled items at a refrigerated temperature hard chill To rapidly decrease the temperature of foods by internal produc...

Страница 23: ...ngs 7 Enter desired time or temperature on number pad or touch to select factory default 8 Touch to enter or to return to settings screen 9 Touch to start the chilling process The screen will indicate...

Страница 24: ...the Hold cycle The screen will indicate Chill Time The length of time the chiller is operating in the preset mode Chill Temperature The preset temperature Hold Temperature The air temperature inside t...

Страница 25: ...d transfer is complete Pull the data stick out of the data port Note If USB is not found when download icon is touched a No USB detected message will display on the screen All data has been transferre...

Страница 26: ...is in process When complete pull the data stick out of the data port Screen will return to Home screen Note Download cannot be done when QC2 is in chill mode Software Upgrade 1 Insert USB data stick i...

Страница 27: ...defrost cycle The length of time can be adjusted by touching or to adjust defrost cycle time Probe calibration Touch The offset and the temperature will display for probe 1 top 2 middle and 3 bottom...

Страница 28: ...ult setting is 10 minutes Use or to adjust the drip time within a range of 5 15 minutes Probes Touch to indicate the number of probes being used in the chiller 0 1 or 3 Factory Settings Touching will...

Страница 29: ...l be highlighted if error is present HMI 01 01H ID 01 A5 FF FF FF FF RB 00 91 Cavity 0 F Probe 1 0 F Probe 2 0 F Probe 3 0 F Coil 0 F Door Defrost In 00 00 00 Defrost 0000 00 00 00 Drain Heater 0000 0...

Страница 30: ...Amount of time without power Touch to clear display and stop audible signal 00 00 05 Power Outage If a power failure occurs the control will produce an audible signal every 10 seconds and the display...

Страница 31: ...l pad or sanitizing solution recommended for food contact surfaces 3 Reattach the probes to the receptacles and place probes into the proper probe bracket 4 Wipe each probe with a disposable alcohol p...

Страница 32: ...ork chops or meat patties should be chilled directly on the sheet pans on which they were cooked Cover the sheet pans with clear plastic wrap for chilling After chilling this type of product can be pl...

Страница 33: ...ture for frozen food DO NOT OVERLOAD THE QUICKCHILLER FOR THE PROCESSING FUNCTION c h i l l i n g PAN C a p a c i t y CHART chiller model no pans standard pan sizes total weight gastronorm pan sizes t...

Страница 34: ...s Waffles French Toast 2 to 3 each 4 oz 113 gm 48 Eggs 2 to 4 oz 57 to 113 gm 96 to 48 Breakfast Meats 2 oz 57 gm 96 Cooked Cereals or Grains 4 oz 113 gm 48 Fruit Compote 4 oz 113 gm 48 Meat Poultry F...

Страница 35: ...rranty Always use the proper cleaning agent at the manufacturer s recommended strength Contact your local cleaning supplier for product recommendations cleanIng MaterIals Cleaning can usually be accom...

Страница 36: ...G COMPOUNDS OR IMPLEMENTS Probe Cleaning Procedures 1 Remove all food soil from probes between loads and at the end of each production shift Wipe entire probe cable assembly and probe holding door bra...

Страница 37: ...not ticking Control failure Replace control E 80 EEPROM error This error message indicates the control memory is not correctly reading user set values The Quickchiller will remain operational but the...

Страница 38: ...4 5b CS 29822 Caster Assembly 4 CS 29822 3 Caster Non Locking Option 4 SC 29824 Bolt 1 4 20 x 5 Shoulder 4 6 SC 29824 Bolt 1 4 20 x 3 5 Shoulder Bolt Hex Head 16 7 BT 29820 Electrical Mounting Bracke...

Страница 39: ...4 25 Push In Press In 1 8 DR 29833 Door Hinged Left 1 9 HG 35736 Hinge Top Door Left Hand Channel 1 10 PI 35930 Hinge Pin 1 11 SC 29835 Screw 10x1 2 T H P 410 S S M4XG 1 Item Part Description Qty 12 H...

Страница 40: ...tor Fan ESP OL75EM14 1 5 SC 29855 Bolt 10 24x5 Phillip Truss 19 6 BT 29847 Evaporator Coil Mounting Bracket 2 7 VA 29852 Valve 1 4 Ton R404 L T MOP 1 8 RE 29846 Coil Assembly 12x17 1 4 Blast Chiller 3...

Страница 41: ...V 1 2 SW 29823 Pressure Switch 1 3 FI 29862 Dryer 1 4 Filter with 2nd 1 4 1 4 Service Valve King 1 5 VA 29863 Solenoid Valve 120V Coil 2 6 Compressor 1 7 Service Valve Suction 1 8 VA 29864 Valve Sporl...

Страница 42: ...27 Power Supply 115V to 12VDC 1 3 CB 35746 Connector USB Panel Mount 1 4 PE 36160 Panel Overlay 1 5 PN 29932 Control Panel 1 6 CB 36571 USB Communication Cable w plug 1 7 CC 36418 User Interface Board...

Страница 43: ...29969 Stainless Steel Side Rack Optional 2 13 5014889 Leg Assembly Set of 4 4 LG 29904 Leg 6 1 14 SC 29824 Bolt 1 4 20 x 5 Shoulder 4 Item Part Description Qty 1 PR 35771 Probe Receptacle Assembly 1...

Страница 44: ...r 1 3 PR 35771 Probe Receptacle Assembly 1 4 PR 36201 Probe Product 1 5 SN 33541 Sensor Air 1 6 PR 37483 Coil Sensor Defrost Sensor 1 7 PN 29943 Drip Pan 1 8 WI 35157 Wire 11 279mm Loop Drain Heater 1...

Страница 45: ...ondensing Unit 3 4 HP LT R404A 120V 1 6 FI 29954 Filter Dryer 1 7 Compressor 1 8 BT 29951 Bracket Back Compressor Hold Down 1 9 RE 29966 Condensate Evaporator Pan includes Hold Down Bracket 1 10 EL 29...

Страница 46: ...tion Qty 1 CC 36418 User Interface Board and Firmware 1 2 SC 29991 Screw 6 32x1 2 T H P 18 8 SS Philllips Truss 4 3 PE 36130 Panel Overlay 1 4 CB 35746 Connector USB Panel Mount 1 5 PN 29962 Control P...

Страница 47: ...Qty 1 RE 35155 Coil Solenoid 120V 18Z7612 2 2 VA 29898 Valve Liquid Line Solenoid 2 3 RE 37503 Compressor 1 5 HP LO R404A 230V 1PH 1 4 RE 37506 Transducer Suction Pressure 929 0114 00 1 5 RE 37505 Si...

Страница 48: ...p 60 Hz 1 2 PE 37484 Compressor Louver 1 3 BT 29950 Hold Down Clip 2 4 5014889 Leg Assembly Set of 4 4 LG 29904 Leg 6 1 SC 29824 Bolt 1 4 20 x 5 Shoulder 4 SC 29824 Leg Bolt 1 4 20 x 3 5 Shoulder Bolt...

Страница 49: ...33541 Air Sensor 1 2 Air Sensor Mounting Bracket 1 3 Housing Refrigeration Enclosure 1 4 PR 37483 Coil Sensor Defrost Sensor 1 5 VA 29906 Valve Expansion 2 6 Drain Pan Evaporator 1 7 Clip Left Coil 2...

Страница 50: ...nf o r ma tion Q C 2 4 0 DOOR 2 3 4 5 1 Item Part Description Qty 1 DR 36748 Door Assembly Left Hand 1 contact factory Door Assembly Right Hand 1 2 HD 29958 Handle Door 1 3 HG 36650 Hinge 1 4 HL 29840...

Страница 51: ...MN 36580 Rev 2 01 16 Quickchillers 49 parts information Q C 2 4 0 pa n supports 1 Item Part Description Qty 1 SR 36881 Rack Pan Support 18...

Страница 52: ...4 CB 36571 USB Communication Cable w plug 1 5 CU 29964 Capacitor 14MFD 440VAC 2 6 SC 29991 Screw 6 32 x 1 2 T H P 180 8 SS 08BC Phillips Truss SS 1 7 BU 33619 Plug 1 8 CC 29930 Control Panel Assembly...

Страница 53: ...3 TE 35153 Tee Copper 1 2 x 1 2 x 3 8 ID 1 4 VA 29898 Valve Liquid Line Solenoid 2 5 TE 35154 Tee Copper 1 1 8 x 1 1 8 x 5 8 OD 1 6 EL 35152 Elbow Copper 1 4 Street 2 7 FI 29987 Filter Drier 1 8 VA 2...

Страница 54: ...coIL 1 2 3 4 Item Part Description Qty 1 RE 29905 Coil Assembly 19x20 3 2 VA 29906 Valve Expansion 3 3 TE 35153 Tee Copper 1 2 x 1 2 x 3 8 ID 1 4 TE 29985 Tee Copper 1 2 x 1 2 x 1 4 ID 1 5 FA 29945 E...

Страница 55: ...tion Qty 1 DR 29990 Door Assembly Left Hand 1 contact factory Door Assembly Right Hand 1 2 HD 26967 Handle Door LH 1 HD 26966 Handle Door RH 1 3 HG 36650 Hinge Adjustable 3 4 GS 29994 Gasket Compressi...

Страница 56: ...p 1 3 PN 29842 Louver Panel 1 4 PN 29999 Panel Control Panel Assembly Left Hand 1 contact factory Panel Control Panel Assembly Right Hand 1 5 DR 29990 Door Assembly Left Hand 1 contact factory Door As...

Страница 57: ...3 11 PR 35486 Probe Receptacle 3 Q C 2 1 0 0 NT Narrow Trolley l e f t h a n d d o o r s h o w n 1 10 11 5 3 4 2 9 7 8 6 Item Part Description Qty 1 RE 29983 Condensing Unit 3HP 208 230V 1 Phase 1 RE...

Страница 58: ...tor USB Panel Mount 1 3 CB 35769 USB Communication Cable 1 4 PN 29999 Control Panel Left Hand 1 contact factory Control Panel Right Hand 1 5 LT 26968 Door Latch Left Hand 1 LT 26969 Door Latch Right H...

Страница 59: ...ce or fifteen 15 months from the shipping date whichever occurs first The labor warranty period is one 1 year from the date of installation or fifteen 15 months from the shipping date whichever occurs...

Отзывы: