Error Code

1

. Control displays “OOO” or “PFO”.

2. Control displays “CCC” or “PFC”.

3.  Unit does not operate.

4.  No display in electronic control.

5.  Cannot control temperature but sensor

and electronic control check OK.

6.  Temperature readout incorrect.

Possible Cause

A. Sensor is open circuited.

B.

Associated wiring is open circuited.

C.

Control is faulty.

A.

Sensor is short circuited.

B.

Associated wiring is short circuited.

C.

Control is faulty.

A.

Insufficient power supply.

B.

Defective power cord or plug.

A.

Faulty power supply board.

B.

Faulty electronic control.

A.

Faulty relay.

B.

Heating element sensor.

A.

Dirty or faulty sensor.

B.

Faulty control.

Action Required

Detach the sensor from the terminal block.
Use an Ohm meter to measure the resistance
of the sensor.  Check sensor at 32°F (0°C)
using a container of ice water.  If Ohm read-
ing is 100, replace display.  If Ohm reading 
is not 100, replace sensor.

Check wires for integrity.  Check for proper
and secure connections at the thermostat and
terminal block.  If necessary, re-secure the
faulty connections.

Energize system after the above steps have
been completed.  If control still reads "OOO
or PFO", contact factory.

Detach the sensor from the terminal block.
Use an Ohm meter to measure the resistance
of the sensor.  Check sensor at 32°F (0°C)
using a container of ice water.  If Ohm read-
ing is 100, replace display.  If Ohm reading 
is not 100, replace sensor.

Check wires for integrity.  Check for proper
and secure connections at the thermostat and
terminal block.  If necessary, re-secure the
faulty connections.

Energize system after the above steps have
been completed.  If control still reads "CCC
or PFC", contact factory.

Check power source.

Check and replace if necessary.

Check line voltage for 24V across pins 6 and
7 on the power supply board.
Replace control.

Replace relay.

Replace element.

Detach the sensor from the terminal block.
Use an Ohm meter to measure the resistance
of the sensor.  Check sensor at 32°F (0°C)
using a container of ice water.  If Ohm read-
ing is 100, replace display.  If Ohm reading 
is not 100, replace sensor.

This chart is provided for the assistance of 

qualified technicians only

and is not intended for use by untrained or 

unauthorized service personnel.  If your unit is not operating properly, check the following before calling your 
authorized service agent.  Check the power applied to the unit.  Plug in outlet?  Fuse OK?

Do not attempt to repair or service beyond this point.  Contact manufacturer for nearest authorized service agent.  
Repairs made by any other service agent without prior authorization by manufacturer will void the warranty on the unit.

Tr o u b l e   S h o o t i n g   G u i d e

EXT. WIRES

SENSOR

T-BLOCK

CONNECTORS

EXT. WIRES

SENSOR

T-BLOCK

CONNECTORS

 SET

prg

!

ERROR CODE

INDICATOR L.E.D.

HEAT

INDICATOR L.E.D.

ERROR

CODE

DISPLAY

TEMPERATURE

SET

BUTTON

L.E.D.1

INCREASE/DECREASE

ROCKER BUTTON

ooo

POWER
ON/OFF

ROCKER SWITCH

 SET

prg

!

ERROR CODE

INDICATOR L.E.D.

HEAT

INDICATOR L.E.D.

ERROR

CODE

DISPLAY

TEMPERATURE

SET

BUTTON

L.E.D.1

INCREASE/DECREASE

ROCKER BUTTON

CCC

POWER
ON/OFF

ROCKER SWITCH

THIS SECTION IS PROVIDED FOR THE 
ASSISTANCE OF QUALIFED SERVICE
TECHNICIANS ONLY AND IS NOT 
INTENDED FOR USE BY UNTRAINED OR 
UNAUTHORIZED SERVICE PERSONNEL.

Содержание 600-LVD

Страница 1: ...Falls Wisconsin 53052 0450 USA PHONE 262 251 3800 800 558 8744 USA CANADA FAX 262 251 7067 800 329 8744 U S A ONLY WEBSITE www alto shaam com P R I N T E D I N U S A H o t F o o d D i s p l a y C a b...

Страница 2: ...r installing the equipment model Contact the Alto Shaam service department if you have any questions concerning installation opera tion or maintenance NOTE All claims for warranty must include the ful...

Страница 3: ...ard that can or will cause minor personal injury property damage or a potential unsafe practice if the warning included with this symbol is ignored Used to notify personnel of instal lation operation...

Страница 4: ...liance from side to side and back to back with the use of a spirit level 5 In order to maintain standards established by the National Sanitation Foundation all stationary counter mounted equipment mus...

Страница 5: ...UGH 40 1016mm 24 1 2 622mm 20 5 8 524mm 2 5 16 59mm BETWEEN SHELVES 19 7 8 505mm 31 1 2 800mm 1 1 8 29mm 1 1 8 29mm PASS THROUGH Outside Dimensions Options and Accessories Legs 4 102mm 4249 Wire Shelf...

Страница 6: ...ial difference The terminal is marked with the following symbol NOTE The appliance must be connected to an electrical circuit that is protected by an external GFCI outlet ELECTRICAL VOLTAGE PHASE CYCL...

Страница 7: ...erature is 200 F 93 C SET Button The SET button is used to display the current set point temperature or program a new set point temperature Pushing the SET button once will display the set point tempe...

Страница 8: ...ming chamber calls for heat It will extinguish when the warming chamber s interior temperature reaches the set point Use hand protection when handling hot items Be certain only hot foods are placed in...

Страница 9: ...of 1 to 2 minutes must be the only time period allowed for the initial heat to be released from the product This unit is equipped with a thermostat control between 60 and 200 F 16 and 93 C If the uni...

Страница 10: ...d foods should be removed and the area wiped as soon as possible but at the very least a minimum of once a day Always thoroughly rinse surfaces after using a cleaning agent and wipe standing water as...

Страница 11: ...atic acid on stainless steel 6 Clean control panel door vents door handles and door gaskets thoroughly since these areas harbor food debris 7 Rinse surfaces by wiping with sponge and clean warm water...

Страница 12: ...method of measuring safe temperatures of both hot and cold foods is by internal product temperature A quality thermometer is an effective tool for this purpose and should be routinely used on all pro...

Страница 13: ...the air sensor See troubleshooting guide in this manual or call the factory service department for advice 824 Operation and Care Manual 12 S E R V I C E ERROR CODE DISPLAYS Open Circuited If 000 is di...

Страница 14: ...minal block If necessary re secure the faulty connections Energize system after the above steps have been completed If control still reads CCC or PFC contact factory Check power source Check and repla...

Страница 15: ...2 SC 2425 2 CASING CONTROL COVER RED 600 LVD PT 1 12244 CASING CONTROL COVER WHITE LVD 60 P 1 13049 CASING MOUNTING SCREWS 2 SC 2425 THREADED BUMPER not shown 4 BM 22606 3 SNAP IN POCKET PULLS 4 PL 22...

Страница 16: ...824 Operation and Care Manual 15 S E R V I C E...

Страница 17: ...824 Operation and Care Manual 16 S E R V I C E...

Страница 18: ...824 Operation and Care Manual 17...

Страница 19: ...824 Operation and Care Manual 18...

Страница 20: ...rom the shipping date whichever occurs first THIS WARRANTY DOES NOT APPLY TO 1 Calibration 2 Replacement of light bulbs and or the replacement of display case glass due to damage of any kind 3 Equipme...

Отзывы: