When installing or using the Altman Smart-Track
®
System, basic safety precautions should
always be followed, including:
1. Read and understand all of these installation instructions before installing the
SMART-TRACK
®
fixtures and lighting track.
2. Only a qualified electrician in accordance with the National Electrical Code and all local
codes and ordinances should perform installation of the Smart Track system.
3. Do not install the track in damp or wet locations.
4. Do not install any parts of the track system less than 5 feet above the floor.
5. Do not install any fixtures closer than six inches from combustible materials.
6. Do not use this track with a power supply cord or convenience receptacle adaptor.
7. The Altman Smart-Track System is intended for use only with Altman Smart Track com-
ponents and fixtures marked for use with the Altman Smart Track System. To reduce the
risk of fire and electric shock, do not use other components as part of this system.
Data Cable
shall be suitable for transport of USITT DMX-512A (ANSI E1.11-2004) and
RDM (ANSI E1.20-2006) control information between Smart Track Sections and the Light-
ing Control System (example: Belden 9842) or CAT-5 Ethernet cable (Example: Belden
1583A) can be used.
DO NOT CONNECT DMX PIN 1/ DIGITAL COMMON, DIRECTLY TO EARTH
AC GROUND AT THE TRACK POWER/ DATA FEEDS.
DMX/ Data Digital Common is allowed to float at track Power/ Data feeds and remains
un-terminated.
8. The 2-circuit track contains 2 hot circuits and 2 neutral conductors, allowing a
maximum load of 2 x 20A at 120 volts.
9. Insure that ALL lighting branch circuits for the smart track are dedicated and
NOT connected to an in-line dimmer.
10. Do not attempt to energize anything other than Lighting Track Fixtures on the lighting
track. To reduce the risk of fire and electrical shock, do not attempt to connect
power tools, extension cords, appliances, and the like to the lighting track.
11. Data Control Wires (+/-) on the 2-circuit adaptors and track are to be used for DMX or
RDM control signals only, rated max. 5 volts, 1 Amp.
12. During installation, do not connect data control cables to the lighting track with electric
power connected. Power off the lighting track first, insert the data control cable, and
then turn power back onto the lighting track. Voltage spikes can damage the
fixtures.
13. Keep the data rail control circuits on the lighting track as clean as possible. Use a clean
lint-free cloth with isopropyl alcohol to clean the data rail control circuits in the
event of dirt and dust collection. The data control lines have to be absolutely clean
and free of dirt and dust for a reliable connection with the data contacts of the fixture
Altman Lighting 2 Circuit
Smart Track
Important Safety & Installation instructions