background image

SPECIAL APPLICATION

400-0517-001

21

OPERATION

7

The 

CP450

is designed for use in a fixed 

application where the system boots up directly into 
the user application and does not allow  access to 
the operating system.  The application and GUI 
interface are normally created using a standard 
desktop computer and then installed onto the 

CP450

using a USB drive or network connection.

Once set-up, the 

CP450

will work trouble-free 

without user intervention.   

7.1 POWER UP and SHUTDOWN

The 

CP450

boots automatically as soon as power 

is applied. There is no need to press the power 
switch on the bottom of the unit.  In most 
installations, the system boots directly into the 
end-user application.

The 

CP450

can be powered down using the 

shutdown/power off option from the START menu, 
or directly from an AVSnap application using the 
“App1.Shutdown” function.

7.2 PREPARING CONTROL SOFTWARE

It is not recommended to design and create control 
software directly on the 

CP450

. In most situations, 

it is easier and faster to write and debug control 
software on a standard desktop computer and then
transfer the completed file when ready. However, if 
the 

CP450

needs to be programmed “in place”, use 

an external USB keyboard and mouse. Simply plug 
in the devices and wait for the system to recognize 
the new hardware and load the drivers.

Remember, the 

CP450

employs the Enhanced 

Write Filter (EWF) to protect the contents of the 
internal drive. Read the next section carefully 
before attempting to install, create, or edit any data 
files or applications on the 

CP450

. If not executed 

properly, changes will be lost.

The best way to create and edit on the 

CP450

is to 

use a USB drive plugged into the bottom of the unit 
and make changes directly to the USB drive then 
copy the final files to the 

CP450

’s “C” drive.

7.3 INSTALLING FILES AND APPLICATIONS

The 

CP450

utilizes the Windows XP Embedded 

EWF to protect the 

CP450

’s internal memory from 

accidental or unauthorized changes. The EWF 
appears to read and write from the internal drive, 
but executes everything in RAM. All changes WILL 
be lost after reset or shutdown unless the changes 
are committed to memory. Three batch files are 
provided for direct control over the EWF and should 
be used cautiously.

1. COMMIT.BAT – Write to hard drive

This batch file resides on the desktop and writes 
the RAM data onto the hard drive for permanent 
storage  while  EWF is enabled.  Close open 
applications before running this batch file or the 
changes may not be committed to memory.

2. ENABLE.BAT – Turn on EWF

This batch file resides in the root directory and 
turns on the EWF. In this mode, no changes
made to the system are saved unless the 
COMMIT batch file is executed. This is the 
default condition for all 

CP450

s. 

3. DISABLE.BAT – Turn off EWF

This batch file resides in the root directory and 
turns off the EWF. In this mode, the system 
operates like a normal computer reading and 
writing data directly to the hard drive. 

WARNING

When the EWF is turned  off, the user MUST 
shutdown the computer properly. If power is 
turned off or lost without  executing the normal 
shutdown procedure, data can be lost, or 
corrupted, including the BIOS and operating 
system (OS). If the BIOS or OS are damaged, 
the entire system can become unusable. 

7.3.1 INSTALLING LARGE FILES

If the application or file is too large for the available 
RAM, the operation will be aborted. Use the disable 
batch file before installing the software.  Make sure 
to reset the EWF when done.

Содержание CP450-007

Страница 1: ...SPECIAL APPLICATION MANUAL PART NUMBER 400 0517 001 MULTITOUCH TOUCH SCREEN CONTROLLERS USER S GUIDE CP450 Series...

Страница 2: ...8 DIMENSIONS 14 DIAGRAM 4 CP450 010 DIMENSIONS 15 DIAGRAM 5 CP450 012 DIMENSIONS 16 DIAGRAM 6 CP450 015 DIMENSIONS 17 DIAGRAM 7 CP450 017 DIMENSIONS 18 DIAGRAM 8 CP450 019 DIMENSIONS 19 INSTALLING YOU...

Страница 3: ...to avoid fire shock and loss of power 1 3 CLEANING Unplug the CP450 adapter before cleaning Clean only with a dry cloth Never use strong detergents or solvents such as alcohol or thinner Do not use a...

Страница 4: ...controller can be used to control any number of serial devices using their unique IP address The built in wireless LAN can be used to control remote devices through a wireless router or directly to a...

Страница 5: ...Included Power Adapter AC Power Cord 12VDC Hardware Mounting screws Optional Accessories Stand AC403 101 Panel Mount AC403 104 Wall Mount AC403 109 Table 1 CP450 007 General MECHANICAL CP450 007 Mate...

Страница 6: ...unting screws Optional Accessories Stand AC403 101 Panel Mount AC403 104 Wall Mount AC403 109 Table 4 CP450 008 General MECHANICAL CP450 008 Material ABS w PC Plastic frame Color Black Height 7 2 in 1...

Страница 7: ...unting screws Optional Accessories Stand AC403 102 Panel Mount AC403 105 Wall Mount AC403 109 Table 7 CP450 010 General MECHANICAL CP450 010 Material ABS w PC Plastic frame Color Black Height 8 9 in 2...

Страница 8: ...ardware Mounting screws Optional Accessories Stand AC403 102 Panel Mount AC403 105 Wall Mount AC403 109 Table 10 CP450 012 General MECHANICAL CP450 012 Material ABS w PC Plastic frame Color Black Heig...

Страница 9: ...AC Power Cord 12VDC Hardware Mounting screws Optional Accessories Stand AC403 103 Panel Mount AC403 106 Wall Mount AC403 110 Table 13 CP450 015 General MECHANICAL CP450 015 Material ABS w PC Plastic f...

Страница 10: ...AC Power Cord 12VDC Hardware Mounting screws Optional Accessories Stand AC403 103 Panel Mount AC403 107 Wall Mount AC403 110 Table 16 CP450 017 General MECHANICAL CP450 017 Material ABS w PC Plastic f...

Страница 11: ...r AC Power Cord 12VDC Hardware Mounting screws Optional Accessories Stand AC403 103 Panel Mount AC403 108 Wall Mount AC403 110 Table 19 CP450 019 General MECHANICAL CP450 019 Material ABS w PC Plastic...

Страница 12: ...SPECIAL APPLICATION 400 0517 001 11 PRODUCT DESCRIPTION 4...

Страница 13: ...SPECIAL APPLICATION 400 0517 001 12 APPLICATION DIAGRAMS 5 DIAGRAM 1 TYPICAL SETUP...

Страница 14: ...SPECIAL APPLICATION 400 0517 001 13 DIAGRAM 2 CP450 007 DIMENSIONS 8 9 226 mm 5 9 151 mm 8 4 214 mm 3 5 90 mm 0 6 16 mm 1 6 41 mm 4 9 125 mm 5 5 140 mm...

Страница 15: ...SPECIAL APPLICATION 400 0517 001 14 DIAGRAM 3 CP450 008 DIMENSIONS 8 7 220 mm 9 2 234 mm 6 7 170 mm 0 7 17 mm 1 7 42 mm 7 2 184 mm 6 8 172 mm 5 0 128 mm...

Страница 16: ...SPECIAL APPLICATION 400 0517 001 15 DIAGRAM 4 CP450 010 DIMENSIONS 2 0 51 mm 0 9 24 mm 10 0 253 mm 8 9 227 mm 10 9 276 mm 8 3 212 mm 8 0 204 mm 6 3 159 mm...

Страница 17: ...SPECIAL APPLICATION 400 0517 001 16 DIAGRAM 5 CP450 012 DIMENSIONS 11 0 279 mm 0 9 24 mm 2 0 51 mm 9 7 246 mm 12 0 304 mm 9 8 248 mm 8 7 221 mm 7 4 187 mm...

Страница 18: ...SPECIAL APPLICATION 400 0517 001 17 DIAGRAM 6 CP450 015 DIMENSIONS 12 6 320 mm 9 1 230 mm 7 8 199 mm 9 3 235 mm 12 2 309 mm 15 5 394 mm 12 1 306 mm 2 4 61 mm 1 2 30 mm...

Страница 19: ...SPECIAL APPLICATION 400 0517 001 18 DIAGRAM 7 CP450 017 DIMENSIONS 13 8 351 mm 10 7 272 mm 16 9 428 mm 13 4 340 mm 8 7 220 mm 10 3 261 mm 13 8 350 mm 2 6 66 mm 1 3 34 mm...

Страница 20: ...SPECIAL APPLICATION 400 0517 001 19 DIAGRAM 8 CP450 019 DIMENSIONS 15 1 384 mm 11 9 303 mm 18 5 470 mm 14 9 378 mm 2 6 67 mm 1 4 36 mm 10 4 264 mm 11 8 300 mm 15 1 383 mm...

Страница 21: ...control software using your normal software development station The CP450 is not required We recommend using AVSnap as the control software It is free easy to use and has many features designed for us...

Страница 22: ...e CP450 is to use a USB drive plugged into the bottom of the unit and make changes directly to the USB drive then copy the final files to the CP450 s C drive 7 3 INSTALLING FILES AND APPLICATIONS The...

Страница 23: ...ndby the computer per display property settings App1 RunScreensaver Launch the screensaver If no screensaver is installed this command has no effect TROUBLESHOOTING GUIDE 8 We have carefully tested an...

Страница 24: ...Y RETURN POLICIES Please see the ALTINEX website at www altinex com for details on warranty and return policies 9 2 CONTACT INFORMATION ALTINEX Inc 592 Apollo Street Brea CA 92821 USA TEL 714 990 2300...

Отзывы: