background image

SPECIAL APPLICATION

400-0517-001

20

INSTALLING YOUR  CP450

6

The installation and setup steps may be performed 
concurrently in order to save time.

At the time of purchase, determine if the 

CP450

will 

be mounted on a stand, wall, or panel.  The 
mounting stand or brackets can be purchased from 
ALTINEX.

NOTE: The mounting holes on the rear of the 

units are VESA standard. The 7-10 inch 
models use 75x75 mm spacing, the 15-19 
inch models use 100x100 mm, and the 
12 inch has both.

INSTALLATION

Step 1.

Determine the best location for installing 
the 

CP450

. At a minimum, the 

CP450

will 

require AC power for its power adapter. 

ADDITIONAL CONSIDERATIONS

If the CP450 will control RS-232
equipment directly from its serial ports, 
RS-232 cables  must be routed to the 
devices.

If the CP450 will connect to the 
network, LAN access and network 
cables are required.

Make sure there is access to the USB 
ports.  The USB ports are accessible 
from the bottom of the unit and should 
not be blocked by mounting hardware, 
cables, etc.

Step 2.

Route all cables required for the

CP450 

to 

the installation locations. Make sure the 
cables are long enough to allow for 
service loops and to be routed neatly to 
their destinations.

Step 3.

Have qualified personnel install the 
mounting brackets (or other hardware) for 
the 

CP450

.

SETUP

Step 1.

Prepare the control software using your 
normal software development station. The 

CP450

is not required. We recommend 

using AVSnap as the control software. It 
is free, easy to use, and has many 
features designed for use with the 

CP450

.

Step 2.

Debug the control software using the 
device for which it was written. The 

CP450

is a normal computer and its COM 

and LAN ports work the same as a 
desktop computer.

Step 3.

When the control software is complete, 
copy all necessary files to a USB drive.

Step 4.

Connect the power adapter provided with 
the 

CP450

to AC power and then to the 

CP450

.

Step 5.

The 

CP450

boots

automatically and 

launches a MultiTouch demo written in 
AVSnap. You can view the demo, or 
escape out of AVSnap and return to the 
desktop.

Step 6.

Install the USB drive into the 

CP450

and 

copy the files over to the “C” drive. If any 
application software is required, install it 
at this time. Once all the software has 
been installed, close all open applications 
and run the COMMIT batch file located on 
the desktop. This will commit the changes 
made to the internal drive.

NOTE:

If an installation wizard requests a restart 
to complete the installation, answer NO. 
The COMMIT batch file must be run first.

Step 7.

Restart the 

CP450

and verify all the 

changes are present. Place a shortcut to 
the new control software into the startup 
folder and remove the AVSnap demo. 
Run the COMMIT batch file again and 
restart the 

CP450

.

Step 8.

The unit is now operational. Verify the 

CP450

boots up and automatically 

launches the control software.

Содержание CP450-007

Страница 1: ...SPECIAL APPLICATION MANUAL PART NUMBER 400 0517 001 MULTITOUCH TOUCH SCREEN CONTROLLERS USER S GUIDE CP450 Series...

Страница 2: ...8 DIMENSIONS 14 DIAGRAM 4 CP450 010 DIMENSIONS 15 DIAGRAM 5 CP450 012 DIMENSIONS 16 DIAGRAM 6 CP450 015 DIMENSIONS 17 DIAGRAM 7 CP450 017 DIMENSIONS 18 DIAGRAM 8 CP450 019 DIMENSIONS 19 INSTALLING YOU...

Страница 3: ...to avoid fire shock and loss of power 1 3 CLEANING Unplug the CP450 adapter before cleaning Clean only with a dry cloth Never use strong detergents or solvents such as alcohol or thinner Do not use a...

Страница 4: ...controller can be used to control any number of serial devices using their unique IP address The built in wireless LAN can be used to control remote devices through a wireless router or directly to a...

Страница 5: ...Included Power Adapter AC Power Cord 12VDC Hardware Mounting screws Optional Accessories Stand AC403 101 Panel Mount AC403 104 Wall Mount AC403 109 Table 1 CP450 007 General MECHANICAL CP450 007 Mate...

Страница 6: ...unting screws Optional Accessories Stand AC403 101 Panel Mount AC403 104 Wall Mount AC403 109 Table 4 CP450 008 General MECHANICAL CP450 008 Material ABS w PC Plastic frame Color Black Height 7 2 in 1...

Страница 7: ...unting screws Optional Accessories Stand AC403 102 Panel Mount AC403 105 Wall Mount AC403 109 Table 7 CP450 010 General MECHANICAL CP450 010 Material ABS w PC Plastic frame Color Black Height 8 9 in 2...

Страница 8: ...ardware Mounting screws Optional Accessories Stand AC403 102 Panel Mount AC403 105 Wall Mount AC403 109 Table 10 CP450 012 General MECHANICAL CP450 012 Material ABS w PC Plastic frame Color Black Heig...

Страница 9: ...AC Power Cord 12VDC Hardware Mounting screws Optional Accessories Stand AC403 103 Panel Mount AC403 106 Wall Mount AC403 110 Table 13 CP450 015 General MECHANICAL CP450 015 Material ABS w PC Plastic f...

Страница 10: ...AC Power Cord 12VDC Hardware Mounting screws Optional Accessories Stand AC403 103 Panel Mount AC403 107 Wall Mount AC403 110 Table 16 CP450 017 General MECHANICAL CP450 017 Material ABS w PC Plastic f...

Страница 11: ...r AC Power Cord 12VDC Hardware Mounting screws Optional Accessories Stand AC403 103 Panel Mount AC403 108 Wall Mount AC403 110 Table 19 CP450 019 General MECHANICAL CP450 019 Material ABS w PC Plastic...

Страница 12: ...SPECIAL APPLICATION 400 0517 001 11 PRODUCT DESCRIPTION 4...

Страница 13: ...SPECIAL APPLICATION 400 0517 001 12 APPLICATION DIAGRAMS 5 DIAGRAM 1 TYPICAL SETUP...

Страница 14: ...SPECIAL APPLICATION 400 0517 001 13 DIAGRAM 2 CP450 007 DIMENSIONS 8 9 226 mm 5 9 151 mm 8 4 214 mm 3 5 90 mm 0 6 16 mm 1 6 41 mm 4 9 125 mm 5 5 140 mm...

Страница 15: ...SPECIAL APPLICATION 400 0517 001 14 DIAGRAM 3 CP450 008 DIMENSIONS 8 7 220 mm 9 2 234 mm 6 7 170 mm 0 7 17 mm 1 7 42 mm 7 2 184 mm 6 8 172 mm 5 0 128 mm...

Страница 16: ...SPECIAL APPLICATION 400 0517 001 15 DIAGRAM 4 CP450 010 DIMENSIONS 2 0 51 mm 0 9 24 mm 10 0 253 mm 8 9 227 mm 10 9 276 mm 8 3 212 mm 8 0 204 mm 6 3 159 mm...

Страница 17: ...SPECIAL APPLICATION 400 0517 001 16 DIAGRAM 5 CP450 012 DIMENSIONS 11 0 279 mm 0 9 24 mm 2 0 51 mm 9 7 246 mm 12 0 304 mm 9 8 248 mm 8 7 221 mm 7 4 187 mm...

Страница 18: ...SPECIAL APPLICATION 400 0517 001 17 DIAGRAM 6 CP450 015 DIMENSIONS 12 6 320 mm 9 1 230 mm 7 8 199 mm 9 3 235 mm 12 2 309 mm 15 5 394 mm 12 1 306 mm 2 4 61 mm 1 2 30 mm...

Страница 19: ...SPECIAL APPLICATION 400 0517 001 18 DIAGRAM 7 CP450 017 DIMENSIONS 13 8 351 mm 10 7 272 mm 16 9 428 mm 13 4 340 mm 8 7 220 mm 10 3 261 mm 13 8 350 mm 2 6 66 mm 1 3 34 mm...

Страница 20: ...SPECIAL APPLICATION 400 0517 001 19 DIAGRAM 8 CP450 019 DIMENSIONS 15 1 384 mm 11 9 303 mm 18 5 470 mm 14 9 378 mm 2 6 67 mm 1 4 36 mm 10 4 264 mm 11 8 300 mm 15 1 383 mm...

Страница 21: ...control software using your normal software development station The CP450 is not required We recommend using AVSnap as the control software It is free easy to use and has many features designed for us...

Страница 22: ...e CP450 is to use a USB drive plugged into the bottom of the unit and make changes directly to the USB drive then copy the final files to the CP450 s C drive 7 3 INSTALLING FILES AND APPLICATIONS The...

Страница 23: ...ndby the computer per display property settings App1 RunScreensaver Launch the screensaver If no screensaver is installed this command has no effect TROUBLESHOOTING GUIDE 8 We have carefully tested an...

Страница 24: ...Y RETURN POLICIES Please see the ALTINEX website at www altinex com for details on warranty and return policies 9 2 CONTACT INFORMATION ALTINEX Inc 592 Apollo Street Brea CA 92821 USA TEL 714 990 2300...

Отзывы: