MULTI-TASKER

11

11

[ON…..F]: feedback

After processing a command, an OK or ER will 
be returned as feedback if "F" is included at the 
end of a command string or if the unit ID is zero.

Example

:

[ON1C2U3

F

]: if path is not set

[ON1C2U3

PF

]: if path is set 

5. [OFF]

This command disables one or more outputs of 
a single card or a group of cards. 

[OFFmCnUiS]: for a single card 

This command disables output “m” without 
affecting any other outputs.

m = output number (m = 1 to 8) 

n = card ID No. (n = slot # from 1 to 19) (1 to 8 
for MT100-101 or 1 to 4 for MT100-106)

I = Unit ID number (i = 0 to 9) 

S = saves command to memory

[OFFCnUi]: 

Turns OFF all outputs of the card

Example:

1) If card 5 of unit 3 has output 1, 2 and 3 ON:

a) [

OFF1C5U3]:

Turns OFF output 1 while 

output 2 and 3 remain ON.

b) 

[OFF23C5]:

Turns OFF output 2 and 3.

2) If card 5 of unit 3 has output 1, 2, 3, 4, 5, 6, 

7 and 8 ON:

a)

[OFFC5U3]: 

Turns OFF all outputs, which is 

equivalent to 

[OFF12345678C5U3]

.

[OFFmGkUiS]: for a group of cards

This command disables output "m" for each 
card in group "k" of unit "i".

Command Format: [OFFmCnUiP]

m = card output (m = # from 1-8)

k =  group number (k = # from 1-9) (1 to 8 for 
MT100-101 or 1 to 4 for MT100-106)

i =   unit number (i = # from 0-9) 

S = saves command to memory

Example:

1. [OFF1G5U1]: Turns OFF output 1 for each 
card in group5 of unit 1.

2. [OFFG5U1]: Turns OFF all outputs for each 
card in group5 of unit 1.

[OFF…..P]: sets path

This command will set the path for the output, 
but it is not active until the switch command is 
executed ([SW]). Commands ending in "P" are 
not executed immediately. The path for outputs 
on multiple cards or the same card can be 
loaded.

Command Format: [OFFmCnUiP]

m = output number (m =1 to 8)

n = card ID No. (n = a slot # from 1 to 19) (1 to 8 
for MT100-101 or 1 to 4 for MT100-106)

P = path

Example:

If 2 cards are at slot 6 and 7 of unit 3:

To enable output 1 and 2 of card 6 and output 3 
and 4 of card 7 simultaneously, use the 
following commands:

OFF12C6U3

P

[OFF34C7U3

P

[SW]

If "F" is included use the [OFFmCnUi

PF

command or the [OFFmCnUi

FP

] command.

[OFF…..F]: feedback 

After processing a command, an OK or ER will 
be returned as feedback if "F" is included at the 
end of a command string or if the unit ID is zero.

Содержание 400-0226-003

Страница 1: ...MULTI TASKER MANUAL PART NUMBER 400 0226 003 MT105 110 MT105 111 8 16 IN 8 OUT SYNC MATRIX SWITCHER CARDS FOR MULTI TASKER USER S GUIDE ...

Страница 2: ...ON 3 CLEANING 3 FCC CE NOTICE 3 ABOUT YOUR MT105 110 111 4 TECHNICAL SPECIFICATIONS 4 DESCRIPTION OF MT105 110 111 5 APPLICATION DIAGRAM 6 INSTALLING YOUR MT105 110 111 8 OPERATION 8 RS 232 CONTROL 8 DESCRIPTION OF COMMANDS 8 SUMMARY OF COMMANDS 13 TROUBLESHOOTING GUIDE 13 ALTINEX POLICY 14 ...

Страница 3: ...ts or solvents such as alcohol or thinner Do not use a wet cloth or water to clean the card Do not clean or touch any component or PCB 1 4 FCC CE NOTICE This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause ...

Страница 4: ...components of an RGBHV signal HSync and VSync When using these cards to switch RGBHV format signals it is possible to adapt the 5 BNC connectors to a VGA type 15 pin HD connector using ALTINEX adapter cables such as part MS8102CA TECHNICAL SPECIFICATIONS 3 FEATURES DESCRIPTION MT105 110 111 GENERAL Inputs 8 16 External Input Connectors 8 16 BNC Female Outputs 8 Output Connector 8 BNC Female Compat...

Страница 5: ...MULTI TASKER 5 5 DESCRIPTION OF MT105 110 111 4 ...

Страница 6: ...MULTI TASKER 6 6 APPLICATION DIAGRAM 5 ...

Страница 7: ...MULTI TASKER 7 7 Block Diagrams Internal View of MT105 110 111 ...

Страница 8: ... an OK or ER string will be returned as feedback if F is included at the end of a command string or if the unit ID is zero Commands such as ON OFF and IO that end in S will be saved into memory Commands not ending in S will still be executed but will not be restored when the system is reset power off power on again 7 2 DESCRIPTION OF COMMANDS Each command consists of three parts function card ID a...

Страница 9: ... is connected to Output3 and Output3 is enabled Input2 is connected to Output4 and Output4 is disabled Input8 is connected to Output5 and Output5 is disabled Input7 is connected to Output6 and Output6 is disabled Input10 is connected to Output7 and Output7 is disabled Input16 is connected to Output8 and Output8 is disabled Note If there is no card in slot 2 of unit 3 sending the C2U3 command will ...

Страница 10: ...1 card located in slot 5 of the MT100 100 Enclosure with unit ID3 After the ON12C5U3 and ON3C5U3 commands have been executed output 1 2 and 3 will be ON 3 ONC5U3 Turns ON all outputs of the card ONmGkUiS for a group of cards This command enables output m for each card in group k of unit i m card output m from 1 8 k group number k from 1 9 i unit number i from 0 9 S saves command to memory Example ...

Страница 11: ...s output m for each card in group k of unit i Command Format OFFmCnUiP m card output m from 1 8 k group number k from 1 9 1 to 8 for MT100 101 or 1 to 4 for MT100 106 i unit number i from 0 9 S saves command to memory Example 1 OFF1G5U1 Turns OFF output 1 for each card in group5 of unit 1 2 OFFG5U1 Turns OFF all outputs for each card in group5 of unit 1 OFF P sets path This command will set the pa...

Страница 12: ...a command string or if the unit ID is zero 8 CLR This command clears the members for a single group or for all nine groups CLRCnUi for a single card n Card ID number n 1 to 19 1 to 8 for MT100 101 or 1 to 4 for MT100 106 Ui Unit ID number i 0 to 9 Note that all outputs will be connected to input1 CLRGkUi for a group of cards Gk group number k from 1 9 Ui unit number i from 0 9 Example a To clear g...

Страница 13: ...roups 9 G Requests group data 10 RD Displays the members in each group 11 HELP Displays all commands TROUBLESHOOTING GUIDE 8 We have carefully tested and have found no problems in the supplied MT105 110 111 however we would like to offer suggestions for the following NO DISPLAY Cause 1 The source has a problem Solution Check the source and make sure that there is a signal present and all source co...

Страница 14: ... Please see the Altinex website at www altinex com for details on warranty and return policy 9 1 CONTACT INFORMATION ALTINEX INC 592 Apollo Street Brea CA 92821 USA TEL 714 990 2300 TOLL FREE 1 800 ALTINEX WEB www altinex com E MAIL solutions altinex com FAX 714 990 3303 ...

Отзывы: