background image

 

MULTI-TASKER

13

13

10. [RD]

This command displays the members in each 
group. 

Command Format: [RDGkUi]

k = group number (k = # from 1-9)

i = unit number (i = # from 0-9)

member = C1 - C19 (card 1 to 19) (1 to 8 for 
MT100-101 or 1 to 4 for MT100-106)

Example:

To read member data for group 5 of unit 1, send 
the [RDG5U1] command. The system will return 
feedback as C1C2C3 G5U1

11. [HELP]

This command displays all available commands 
for RS-232 control. 

7.3.SUMMARY OF COMMANDS.

1) [VER]: Receives software version

2) [C]: Receives status of the card

3) [IO]: Connects the input to the output 

4) [ON]: Turns on one or more outputs for a 

single card or a group of  cards

5) [OFF]: Turns off one or more outputs for 

a single card or a group of cards

6) [SW]: Switch (outputs the preloaded 

buffer)

7) [WR]: Groups multiple cards

8) [CLR]: Clears members of a single group 

or all groups

9) [G]: Requests group data

10) [RD]: Displays the members in each 

group.

11) [HELP]: Displays all commands

TROUBLESHOOTING GUIDE

8

We have carefully tested and have found no 
problems in the supplied 

MT105-110/(111)

;

however, we would like to offer suggestions for the 
following:

NO DISPLAY

Cause 1

:

The source has a problem.

Solution: 

Check the source and make sure, that 

there is a signal present and all 
source connections are correct. If the 
source is working and there is still no 
display, see Cause 2.

Cause 2

:

The card input is not selected

.

Solution:

Select the card input. See RS-232 

accessible commands in section 7.If
no display is present see Cause 3.

Cause 3

:

Cable connections to the destination 

are incorrect.

Solution 1:

Make sure that cables are connected 

properly. Also, make sure that the 
continuity and wiring are good. If there 
is still no display present, see Cause 
4.

Cause 4

:

The display has a problem.

Solution 1:

Make sure that the display is powered. 

If there is still no display, call 
ALTINEX at (714) 990-2300

.

Содержание 400-0226-003

Страница 1: ...MULTI TASKER MANUAL PART NUMBER 400 0226 003 MT105 110 MT105 111 8 16 IN 8 OUT SYNC MATRIX SWITCHER CARDS FOR MULTI TASKER USER S GUIDE ...

Страница 2: ...ON 3 CLEANING 3 FCC CE NOTICE 3 ABOUT YOUR MT105 110 111 4 TECHNICAL SPECIFICATIONS 4 DESCRIPTION OF MT105 110 111 5 APPLICATION DIAGRAM 6 INSTALLING YOUR MT105 110 111 8 OPERATION 8 RS 232 CONTROL 8 DESCRIPTION OF COMMANDS 8 SUMMARY OF COMMANDS 13 TROUBLESHOOTING GUIDE 13 ALTINEX POLICY 14 ...

Страница 3: ...ts or solvents such as alcohol or thinner Do not use a wet cloth or water to clean the card Do not clean or touch any component or PCB 1 4 FCC CE NOTICE This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause ...

Страница 4: ...components of an RGBHV signal HSync and VSync When using these cards to switch RGBHV format signals it is possible to adapt the 5 BNC connectors to a VGA type 15 pin HD connector using ALTINEX adapter cables such as part MS8102CA TECHNICAL SPECIFICATIONS 3 FEATURES DESCRIPTION MT105 110 111 GENERAL Inputs 8 16 External Input Connectors 8 16 BNC Female Outputs 8 Output Connector 8 BNC Female Compat...

Страница 5: ...MULTI TASKER 5 5 DESCRIPTION OF MT105 110 111 4 ...

Страница 6: ...MULTI TASKER 6 6 APPLICATION DIAGRAM 5 ...

Страница 7: ...MULTI TASKER 7 7 Block Diagrams Internal View of MT105 110 111 ...

Страница 8: ... an OK or ER string will be returned as feedback if F is included at the end of a command string or if the unit ID is zero Commands such as ON OFF and IO that end in S will be saved into memory Commands not ending in S will still be executed but will not be restored when the system is reset power off power on again 7 2 DESCRIPTION OF COMMANDS Each command consists of three parts function card ID a...

Страница 9: ... is connected to Output3 and Output3 is enabled Input2 is connected to Output4 and Output4 is disabled Input8 is connected to Output5 and Output5 is disabled Input7 is connected to Output6 and Output6 is disabled Input10 is connected to Output7 and Output7 is disabled Input16 is connected to Output8 and Output8 is disabled Note If there is no card in slot 2 of unit 3 sending the C2U3 command will ...

Страница 10: ...1 card located in slot 5 of the MT100 100 Enclosure with unit ID3 After the ON12C5U3 and ON3C5U3 commands have been executed output 1 2 and 3 will be ON 3 ONC5U3 Turns ON all outputs of the card ONmGkUiS for a group of cards This command enables output m for each card in group k of unit i m card output m from 1 8 k group number k from 1 9 i unit number i from 0 9 S saves command to memory Example ...

Страница 11: ...s output m for each card in group k of unit i Command Format OFFmCnUiP m card output m from 1 8 k group number k from 1 9 1 to 8 for MT100 101 or 1 to 4 for MT100 106 i unit number i from 0 9 S saves command to memory Example 1 OFF1G5U1 Turns OFF output 1 for each card in group5 of unit 1 2 OFFG5U1 Turns OFF all outputs for each card in group5 of unit 1 OFF P sets path This command will set the pa...

Страница 12: ...a command string or if the unit ID is zero 8 CLR This command clears the members for a single group or for all nine groups CLRCnUi for a single card n Card ID number n 1 to 19 1 to 8 for MT100 101 or 1 to 4 for MT100 106 Ui Unit ID number i 0 to 9 Note that all outputs will be connected to input1 CLRGkUi for a group of cards Gk group number k from 1 9 Ui unit number i from 0 9 Example a To clear g...

Страница 13: ...roups 9 G Requests group data 10 RD Displays the members in each group 11 HELP Displays all commands TROUBLESHOOTING GUIDE 8 We have carefully tested and have found no problems in the supplied MT105 110 111 however we would like to offer suggestions for the following NO DISPLAY Cause 1 The source has a problem Solution Check the source and make sure that there is a signal present and all source co...

Страница 14: ... Please see the Altinex website at www altinex com for details on warranty and return policy 9 1 CONTACT INFORMATION ALTINEX INC 592 Apollo Street Brea CA 92821 USA TEL 714 990 2300 TOLL FREE 1 800 ALTINEX WEB www altinex com E MAIL solutions altinex com FAX 714 990 3303 ...

Отзывы: