Compact Scaler Switcher (with PoC)
Altimium 18 www.altimium.com
Please set the parameters of COM number, bound rate, data bit, stop bit and the parity
bit correctly, and then you are able to send command in Command Sending Area.
4.4.3 RS232 Communication Commands
Communication protocol:
RS232 Communication Protocol
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
Command
Function
Feedback Example
Switch Commands
50701%
Switch to HDMI 1 input
Switch to HDMI 1
50702%
Switch to HDMI 2 input
Switch to HDMI 2
50703%
Switch to HDMI 3 input
Switch to HDMI 3
50704%
Switch to VGA 1/YPbPr 1/AV 1 input
Switch to VGA 1/YPbPr 1/AV 1
50705%
Switch to VGA 2/YPbPr 2/AV 2 input
Switch to VGA 2/YPbPr 2/AV 2
50680%
Select VGA 1 for INPUT 4
Input 4 Set & Switch to VGA 1
Parameter Configuration area
Monitoring area, indicates if the
command sent works.
Command Sending area
Содержание SCA51T
Страница 1: ...SCA51T Compact Scaler Switcher All Rights Reserved Version SCA51T_2016V1 1 User Manual...
Страница 41: ...Compact Scaler Switcher with PoC Altimium 36 www altimium com 6 Panel Drawing 220 mm 148 mm 119 mm 44 mm...
Страница 45: ......
Страница 46: ......
Страница 47: ......