Compact Scaler Switcher (with PoC)
Altimium 12 www.altimium.com
SCA51T offers the function to remember the last displayed signal when rebooting.
Once rebooted, SCA51T will automatically enter auto-switching mode, and then
detect all inputs and memorize their connection status for future rebooting using.
If the last displayed signal is still available, SCA51T will output the signal. If not,
there will be no signal on output devices.
Signal removing principle
Once removing the current display signal, SCA51T will detect all input signals with
priority from INPUT 1 to INPUT 5. It will transfer the signal firstly detected to be
available to output devices.
Notice
: Auto-switching function works only when inputting new signal, removing a signal
or power rebooting. With any VGA port set to AV or YPbPr, the system will be not able to
enter in Auto-switching mode.
Operation Examples
:
Connect INPUT 2, INPUT 4, and INPUT 5 ports with source devices, select INPUT 4
to outputs.
Press and hold for the front key
SOURCE/AUTO
for
7 seconds or more
to enter in
auto-switching mode.
No signal removing or new input, SCA51T just works in auto-switching mode, and
take no action (Output from INPUT 4)
Connect INPUT 3 with a source device, and then it will choose INPUT 3 to output.
Remove the signal of INPUT 3, SCA51T will detect from INPUT 1 to INPUT 5. And
when it detects that input 2 is available, it will choose INPUT 2 to output.
Cut off the power of SCA51T, then reboot. As SCA51T is in auto-switching mode, it
will choose INPUT 2 to output.
4.1.3 Volume Adjusting
Not in OSD menu, press VOL
– to decrease line volume, VOL + to increase.
Not in OSD menu, press MIC
– to decrease MIC volume, MIC + to increase.
4.1.4 Used in OSD Menu
Press
MENU
button to enter in OSD menu, and use
UP
,
DWON
,
LEFT
,
RIGHT
button
to navigate, press
ENTER
button to confirm selection.
MENU
button also can be used to
exit present menu level by level until exit the OSD menu.
4.1.5 Software updating:
SCA51T supports software updating via USB flash disk.