Integrated Switching Power Supply
Altimium 8 www.altimium.com
Command
Function
Feedback Example
When x =1~5, clear the data of the
Group x.
Clear F[x].
QueryGroup[x].
When x = NULL, query all groups.
Out 01 02 03 04 05 06
07 08 09 10 11 12
Vm1 12 12 12 12 12 12
12 12 12 12 12 12
Vm2 XX XX XX XX XX
XX XX XX XX XX XX XX
……
When x = 1~5, query the group x.
Out 01 02 03 04 05 06
07 08 09 10 11 12
Vm[x] 12 12 12 12 12
12 12 12 12 12 12 12
%0911.
Restore Factory Defaults.
Factory Default
%9964.
Query the IP address.
IP XXX.XXX.X.XXX
ChangeIP
XXX.XXX.X.XXX
Change
IP
address/Subnet
Mask/Gateway,
For
example:
ChangeIP
192.168.0.178/255.255.255.0/0.0.0.0;
%9975.
Query the all status for all channels.
Out 01 02 03 04 05 06
07 08 09 10 11 12
State S S S S S S S S
S S S S
Vm 12 12 12 12 12 12
12 12 12 12 12 12
Over N N N N N N N N
N N N N
Lock N N N N N N N N
N N N N
/*Name;
Query the manufacturer.
XXX
/*Type;
Query the product model
TPUH-PSU12
/^Version;
Query the software version.
V x. x. x
Baud[x].
Set the baud rate as x. x = 1200,
Baud [x] not change.