Integrated Switching Power Supply
Altimium 7 www.altimium.com
Command
Function
Feedback Example
Output/[x]V/[y].
When y = NULL, Set the output
voltage as x for all output channels.
x =5/12/24.
All Output [x]V.
When y =1~12, Set the output voltage
as X for the output channel y.
x =5/12/24.
[y] Output [x]V.
Status[x].
When x = NULL, query the on-off
status of all output channels.
01 Open.
02 Closed.
03 Closed.
…
When x = 1~12, query the on-off
status of the output channel x.
[x] Open.
[x] Closed.
Save[x].
Save the current on-off status to
Group x. x =1~5.
Save To F[x].
Recall[x].
Invoke the on-off status of Group x.
x =1~5.
If Group x has no data,
the feedback information:
F[x] no data.
If Group x has data, the
feedback information:
Recall From F[x].
Out 01 02 03 04 05 06
07 08 09 10 11 12
State S S S S S S S S S
S S S
Vm 12 12 12 12 12 12 12
12 12 12 12 12
Over N N N N N N N N N
N N N
Lock N N N N N N N N N
N N N
Clear[x].
When x =NULL, clear the data of all
Group.
Clear All.