background image

Integrated Switching Power Supply                                                               

 

Altimium                                                                                                    www.altimium.com 

 

13. 

Unplug the apparatus during lightning storms or when unused for long periods of 

time. 

14. 

Refer all servicing to qualified personnel. Servicing is required when the apparatus 

has been damaged in any way, such as power supply cord or plug is damaged, 

liquid has been spilled or objects have fallen into the apparatus has been exposed 

to rain or moisture, does not operate normally, or has been dropped. 

15. 

CAUTION: These servicing instructions are for use by qualified service personnel 

only. To reduce the risk of electric shock, do not perform any servicing other than 

that contained in the operating instructions unless you are qualified to do so. 

16. 

 

  Caution 

– To prevent electric shock hazard, replace grille. 

17. 

Do not install this equipment in a confined or building-in space such as a book case 

or similar unit, and remain a well ventilation conditions at open site. The ventilation 

should not be impeded by covering the ventilation openings with items such as 

newspaper, table-cloths, curtains etc. 

18. 

WARNING: Only use attachments/accessories specified or provided by the 

manufacturer (such as the exclusive supply adapter, battery etc). 

19. 

WARNING

Please refer the information on exterior bottom enclosure for electrical 

and safety information before installing or operating the apparatus. 

20. 

WARNING

To reduce the risk of fire or electric shock, do not expose this apparatus 

to rain or moisture. The apparatus shall not be exposed to dripping or splashing and 

that objects filled with liquids, such as vases, shall not be placed on apparatus. 

21. 

WARNING

For the terminals marked with symbol of “

” may be of sufficient 

magnitude to constitute a risk of electric shock. The external wiring connected to 

Содержание PWSU12

Страница 1: ...PWSU12 Integrated Switching Power Supply All Rights Reserved Version PWSU12_2016V1 0 User Manual...

Страница 2: ...cknowledged as the properties of the trademark owner No part of this publication may be copied or reproduced without the prior written consent FCC Statement This equipment generates uses and can radia...

Страница 3: ...o rain moisture or install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may exp...

Страница 4: ...instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarize...

Страница 5: ...install this equipment in a confined or building in space such as a book case or similar unit and remain a well ventilation conditions at open site The ventilation should not be impeded by covering t...

Страница 6: ...rtable level and reduce the amount of time listening at high levels Headsets should comply with EN 50332 2 requirements for GS certification 26 WARNING The mains plug appliance coupler direct plug in...

Страница 7: ...the user to the presence of important operating and maintenance instructions in the literature accompanying the appliance 28 Protective earthing terminal The apparatus should be connected to a mains...

Страница 8: ...3 3 Connection Procedure 4 4 System Operations 5 4 1 Front Panel Buttons 5 4 2 RS232 Control 5 4 2 1 Installation uninstallation of RS232 Control Software 5 4 2 2 Basic Settings 5 4 2 3 RS232 Communi...

Страница 9: ...5 12 24V DC via the TACT Switch on rear panel RS232 command or web based GUI 1 2 Features Double input channel designed for ensuring the stable AC source Total 12 output channels and each channel has...

Страница 10: ...D will turn green and keep on Long press the button for 3 seconds or more to lock unlock the corresponding channel and then the corresponding LED will flash 3 times Note Pictures shown in this manual...

Страница 11: ...ry setting C 5 12 24V indicators Green when the current selected output voltage is work normally Blinking slowly when the current channel is closed Blinking fastly when the current channel is short ci...

Страница 12: ...the DC ports on rear panel Step2 Connect the PC to the RS232 port on rear panel Step3 Connect the PC to the TCP IP port on the rear panel Step4 Connect the power cables to the one or both of AC1 and A...

Страница 13: ...based on overvoltage protection control and it need to be turned on again via the corresponding output channel switching button on front panel Restore Factory Defaults On rear panel simultaneously lo...

Страница 14: ...ing Area 4 2 3 RS232 Communication Commands Communication protocol RS232 Communication Protocol Baud rate 9600 Data bit 8 Stop bit 1 Parity bit none Command Function Feedback Example All Switch on all...

Страница 15: ...02 Closed 03 Closed When x 1 12 query the on off status of the output channel x x Open x Closed Save x Save the current on off status to Group x x 1 5 Save To F x Recall x Invoke the on off status of...

Страница 16: ...12 12 12 12 12 0911 Restore Factory Defaults Factory Default 9964 Query the IP address IP XXX XXX X XXX ChangeIP XXX XXX X XXX Change IP address Subnet Mask Gateway For example ChangeIP 192 168 0 178...

Страница 17: ...ed for padding For example FA 50 54 4E 00 00 00 00 00 00 00 00 00 00 00 00 00 FE FB XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX FE Modify product model The command has 18 bytes in total and 16 byt...

Страница 18: ...ect a PC to the TCP IP port on the rear panel and set its network segment to the same as the default IP of the product 192 168 0 178 port No 4001 2 Type 192 168 0 178 in your browser it will enter the...

Страница 19: ...log in interface and then click Login to enter Control menu shown as below Select the ON OFF to switch on off the output channel Click the All On to switch on all output channels Click the All Off to...

Страница 20: ...5V 12V or 24V for each output channel 4 3 3 Network Menu Click Network on the top of page to enter network setting menu shown as below In this interface dynamic or static IP mode can be selected Under...

Страница 21: ...4 3 5 Web based GUI Update Web based GUI for the Scaler Switcher supports online update in http 192 168 0 178 100 Type the username and password the same as the GUI log in settings modified password...

Страница 22: ...8 25 2V Maximum output power consumption of signal channel 15W Total output power consumption 180W Control Part Buttons Control Front Panel 01 12 total 12 buttons Rear Panel Total 12 TACT Switches na...

Страница 23: ...1 PWSU12 AC100V 240V Tx Rx RS232 TCP IP 24V AC100V 240V AC1 AC2 DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V...

Страница 24: ...Cannot control the device by control device e g a PC through RS232 port Wrong RS232 communication parameters Type in correct RS232 communication parameters Fail or loose connection Make sure the conn...

Страница 25: ...ealer for checking Cannot control the device by RS232 front panel buttons web based GUI The device has already been broken Send it to authorized dealer for repairing If your problem persists after fol...

Страница 26: ...not cover Warranty expiration Factory applied serial number has been altered or removed from the product Damage deterioration or malfunction caused by Normal wear and tear Use of supplies or parts not...

Страница 27: ......

Страница 28: ...ALTIMIUM 587 Avenue Blaise Pascal 77550 MOISSY CRAMAYEL T l 01 64 13 31 00 Fax 01 60 29 62 70 Mail contact tesca audio com Web www altimium com...

Отзывы: