Single Plug-in Card Matrix Switcher
Altimium 21 www.altimium.com
POEstatus.
Check PoE status of all the signal
cards
“Y” means PoE function is enabled;
“N” means not
Port 01 02 03 04
POE Y Y Y Y
Port 05 06 07 08
POE Y Y Y Y
Port 09 10 11 12
POE Y Y Y Y
%88[XX].
Inquire the command send to port
[XX]+1
[XX]=00~11, get the command sent to
port 1~12 when powered on MATF12
[XX]=12~23, get the command sent to
port 1~12 when powered off MATF12
Port 11: 2A1. when
PWOFF
%9961.
Get current keylock status
System
Unlock!/
System Locked!
%9962.
Inquire current working status
PWON/STANDBY
/PWOFF
%9963.
Return all input& output connection
status
Port 01 02 … …
Mode In Ou … …
Port … … 11 12
Mode … … Ou Ou
%9964.
Inquire the IP
IP: 192.168.0.178
%9973.
Return resolutions of all outputs
Resolution Out05
1920x1080P
… …
%9975.
Get current input& output card
correspondence status
Out 01 02 … …
In 00 06 … …
Out … … 11 12
In … … 06 06
%9976.
Get the output card type
Channel 4 output mode
is
Digital
Channel 6 output mode
is
VGA
Channel 7 output mode
is
Digital
Channel 10 output
mode is VGA
%9977.
Inquire force output signal format
status
Channel
xx
is
auto/manual
signal
format