![Alternate Heating COAL GUN S130 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/alternate-heating/coal-gun-s130/coal-gun-s130_installation-and-operators-manual_2910958021.webp)
Plumbing – Coil in Series
A second method of plumbing the domestic coil
is to connect the coil in parallel with an existing
water heater so that the conventional water heater
may be used when the Coal Gun™ is not being 1red
(for example in the summer). /e diagram that
follows indicates how this can be done.
Plumbing – Coil in Parallel
Tempering valve
/e third method of plumbing the domestic coil
uses a small pump to circulate water continuously
between the coil and existing hot water heater. It is
also necessary to include a tempering valve or
temperature controller on the supply side of the
storage tank/water heater to prevent super-heated
water from reaching the domestic hot water tank
and, ultimately, the faucets.
Plumbing – Coil with circulator
ILLUSTRATED INSTRUCTIONS FOR
INSTALLING COAL HOPPER ON S130 AND
S260
Step 1: Disconnect all power to the boiler.
Step 2: Loosen hopper collar screws until they
are @ush with the inside of the hopper collar.
- 15 -
In installations where the coil
discharges directly into the hot
water distribution system a
tempering valve must be included to
limit the temperature of the water at
the faucet to a safe level.
Содержание COAL GUN S130
Страница 2: ......
Страница 4: ......
Страница 34: ...Appendix A Boiler Specification Diagrams 28 ...
Страница 35: ... 29 ...
Страница 37: ...Appendix B Wiring Diagrams 31 ...
Страница 38: ... 32 ...
Страница 39: ... 33 ...
Страница 40: ...Appendix C Exploded Parts Drawing 34 ...
Страница 51: ...Appendix E Troubleshooting Guide 45 ...
Страница 54: ...Appendix F Table of Figures 48 ...
Страница 57: ...Appendix H Dump Zone Wiring Applications 51 ...
Страница 58: ... 52 ...
Страница 59: ... 53 ...
Страница 60: ... 54 ...
Страница 61: ... 55 ...
Страница 62: ... 56 ...
Страница 63: ...Appendix I Boiler Piping Examples 57 ...