ALTEC AIR, LLC
P550W Series Air Dryers User’s Guide
Page 21 of 98
P011658 – Rev. S
With Compressor running:
6.5.23.2
Use a 1-inch paint
brush to dab soapy
water on the air fitting
or hose connection to be
tested.
If air bubbles appear at the
connection, this indicates that air is leaking from the connection.
If any leaks are detected, take steps to seal them off (as necessary):
Tighten the fitting
Re-connect the hose end
Replace the fitting / hose / component
6.5.24
Re-install the front panel.
6.5.25
REGISTER YOUR DRYER. See section 7. for details.
6.6 Installation Checklist
No shipping damage was detected.
Dryer location meets the following requirements:
o
Well ventilated
o
Free from abrasive dust or chemicals
o
Ambient temperature is between 40° and 85° F (optimal)
System Pressure is set to 50 PSI.
Static Pressure is set to 17 PSI.
No air leaks are present in the system.
No alarms are present on the Display Panel.