7. 

Technical data 

 

a. 

power supply 230VAC, protection fuse 160mA  

b. 

power consumption ~25mA 

c. 

outputs: 

 

8 x relays – 

max. load 3A / 230VAC

 (possible version 8A) 

 

voltage in standard 0÷10VDC 

d. 

colour graphic TFT 320x240 px with backlight 

e. 

Real Time Clock with "GoldCap" or battery supply. 

f. 

temperature sensors type KTY81-110. You can apply your own temperature sensors based on DS18B20 1-WIRE.  
Connection type - "parasite power". After reset, the controller recognizes itself the type of sensor. 

g. 

digital input WE5 for only "floating type" – active when connected. 

h. 

mechanical dimension TFT panel 135*93*28 mm 

i. 

mechanical dimension relay module 177*126*56 mm 

 

8. 

Warranty limited 

a. 

Ltd. "ALRES" ensures the failure-free operation of the equipment within 18 months from the date of the sale. 

b. 

The sale must be made within a period of 24 months from date of manufacture. 

c. 

Disclosed in this period defects will be corrected free of charge by the service according to the following rules: 

 

the controller should be delivered to the place of purchase by the customer at its own expense, in a complete state:  
the control panel with the module relays. 

 

to the controller one must add signed and completed warranty card together with a copy of your receipt 

 

after warranty repair service the controller can be received by the customer or sent to the client without the cost of 
transport. 

 

service will repair it within 14 working days 

 

this period may be extended with the time that is taken to bring the necessary parts. In this case, you will be notified 
about the situation. 

 

the warranty period is extended with the time of repair in the service. 

d. 

The warranty does not include the activities provided in the manual which you must do yourself and at your own expense. 

e. 

If service finds the incompatibility of assembly equipment, recommened in manual, the additional costs will be borne by 
customer, such as repair and shipping costs etc. 

f. 

Guarantee does not cover: 

 

parts subjected to normal wear and tear as accumulators, batteries etc. 

 

mechanical damage and defects caused with them  

 

damage caused with the connection of components exceeding the permitted parameters listed in the specifications. 
This particularly applies to exceeding the load of relay contacts. 

g. 

Warranty repair does not cover damage and defects caused with: 

 

improper or inconsistent with the instructions to connect, use, storage or maintenance 

 

connecting controller to inappropriate residential installation 

 

unauthorized person repairs, alterations or structural changes 

 

damage caused with external factors, independent of manufacturer, such as weather events, flooding, contamination, 
fire, unstable or incorrect power source 

 
 
 
 

           Date of sale 
 
………………………………… 
 
 

 
 

        signature of the buyer 

 

 

 

signature and stamp of the seller 

Содержание MSR-20

Страница 1: ...set of rotation 2 in english ver icon name is rot shortphrase of rotation displaying the shortened information about current configurations sets 3 switching to controller s configuration mode 4 2 Manu...

Страница 2: ...e following functions escape the same function as the Esc computer button the minus value decreasing the value of the edited parameter the plus value increasing the value of the edited parameter appro...

Страница 3: ...to normal operation If you press the switch again during this operation it will cause the break of the procedure and earlier return to normal mode mode 3 Fire protection fan SUPL STOP fan EXH MAX This...

Страница 4: ...eat exchanger Mode OFF the procedure is totally off and system doesn t react for any signal This solution can be use in case that the recuperator is provided with internal defrosting system for ex sup...

Страница 5: ...request It allows to connect the controller to the BMS network by WiFi To set or read parameters controller use 0x03 Read Holding Register 0x06 Write Single Register and 0x10 Write Multiple Registers...

Страница 6: ...nnect gently upper and lower half b The relay module Installation and wiring must be carried out with power off Diagrams are supplied separately The module should be mounted in a recuperator or as clo...

Страница 7: ...ller can be received by the customer or sent to the client without the cost of transport service will repair it within 14 working days this period may be extended with the time that is taken to bring...

Отзывы: